  1. Saidatul A, Azlan C, Megat Amin M, Abdullah B, Ng Kh
    Biomed Imaging Interv J, 2010 Jan-Mar;6(1):e1.
    PMID: 21611060 MyJurnal DOI: 10.2349/biij.6.1.e2
    Computed tomography (CT) fluoroscopy is able to give real time images to a physician undertaking minimally invasive procedures such as biopsies, percutaneous drainage, and radio frequency ablation (RFA). Both operators executing the procedure and patients too, are thus at risk of radiation exposure during a CT fluoroscopy.This study focuses on the radiation exposure present during a series of radio frequency ablation (RFA) procedures, and used Gafchromic film (Type XR-QA; International Specialty Products, USA) and thermoluminescent dosimeters (TLD-100H; Bicron, USA) to measure the radiation received by patients undergoing treatment, and also operators subject to scatter radiation.The voltage was held constant at 120 kVp and the current 70mA, with 5mm thickness. The duration of irradiation was between 150-638 seconds.Ultimately, from a sample of 30 liver that have undergone RFA, the study revealed that the operator received the highest dose at the hands, which was followed by the eyes and thyroid, while secondary staff dosage was moderately uniform across all parts of the body that were measured.
  2. Ho E, Abdullah B, Tang A, Nordin A, Nair A, Lim G, et al.
    Biomed Imaging Interv J, 2008 Oct;4(4):e44.
    PMID: 21611021 DOI: 10.2349/biij.4.4.e44
    To date, the College of Radiology (CoR) does not see any clear benefit in performing whole body screening computed tomography (CT) examinations in healthy asymptomatic individuals. There are radiation risk issues in CT and principles of screening should be adhered to. There may be a role for targeted cardiac screening CT that derives calcium score, especially for asymptomatic medium-risk individuals and CT colonography when used as part of a strategic programme for colorectal cancer screening in those 50 years and older. However, population based screening CT examinations may become appropriate when evidence emerges regarding a clear benefit for the patient outweighing the associated radiation risks.
  3. Ng Kh, Wong J
    Biomed Imaging Interv J, 2008 Apr;4(2):e21.
    PMID: 21614324 DOI: 10.2349/biij.4.2.21
    Informal discussion started in 1996 and the South East Asian Federation of Organizations for Medical Physics (SEAFOMP) was officially accepted as a regional chapter of the IOMP at the Chicago World Congress in 2000 with five member countries, namely Indonesia, Malaysia, Philippines, Singapore and Thailand. Professor Kwan-Hoong Ng served as the founding president until 2006. Brunei (2002) and Vietnam (2005) joined subsequently. We are very grateful to the founding members of SEAFOMP: Anchali Krisanachinda, Kwan-Hoong Ng, Agnette Peralta, Ratana Pirabul, Djarwani S Soejoko and Toh-Jui Wong.The objectives of SEAFOMP are to promote (i) co-operation and communication between medical physics organizations in the region; (ii) medical physics and related activities in the region; (iii) the advancement in status and standard of practice of the medical physics profession; (iv) to organize and/or sponsor international and regional conferences, meetings or courses; (v) to collaborate or affiliate with other scientific organizations.SEAFOMP has been organizing a series of congresses to promote scientific exchange and mutual support. The South East Asian Congress of Medical Physics (SEACOMP) series was held respectively in Kuala Lumpur (2001), Bangkok (2003), Kuala Lumpur (2004) and Jakarta (2006). The respective congress themes indicated the emphasis and status of development. The number of participants (countries in parentheses) was encouraging: 110 (17), 150 (16), 220 (23) and 126 (7).In honour of the late Professor John Cameron, an eponymous lecture was established. The inaugural John Cameron Lecture was delivered by Professor Willi Kalender in 2004. His lecture was titled "Recent Developments in Volume CT Scanning".
  4. Bister M, Yap C, Ng Kh, Tok Ch
    Biomed Imaging Interv J, 2007 Jan;3(1):e9.
    PMID: 21614269 DOI: 10.2349/biij.3.1.e9
    MatLab(®) has often been considered an excellent environment for fast algorithm development but is generally perceived as slow and hence not fit for routine medical image processing, where large data sets are now available e.g., high-resolution CT image sets with typically hundreds of 512x512 slices. Yet, with proper programming practices - vectorization, pre-allocation and specialization - applications in MatLab(®) can run as fast as in C language. In this article, this point is illustrated with fast implementations of bilinear interpolation, watershed segmentation and volume rendering.
  5. Woo M, Ng Kh
    Biomed Imaging Interv J, 2008 Jan;4(1):e13.
    PMID: 21614306 MyJurnal DOI: 10.2349/biij.4.1.e13
    Medical physics is a relatively small professional community, usually with a scarcity of expertise that could greatly benefit students entering the field. However, the reach of the profession can span great geographical distances, making the training of students a difficult task. In addition to the requirement of training new students, the evolving field of medical physics, with its many emerging advanced techniques and technologies, could benefit greatly from ongoing continuing education as well as consultation with experts.Many continuing education courses and workshops are constantly being offered, including many web-based study courses and virtual libraries. However, one mode of education and communication that has not been widely used is the real-time interactive process. Video-based conferencing systems do exist, but these usually require a substantial amount of effort and cost to set up.The authors have been working on promoting the ever-expanding capability of the Internet to facilitate the education of medical physics to students entering the field. A pilot project has been carried out for six years and reported previously. The project is a collaboration between the Department of Medical Physics at the Toronto Odette Cancer Centre in Canada and the Department of Biomedical Imaging at the University of Malaya in Malaysia. Since 2001, medical physics graduate students at the University of Malaya have been taught by lecturers from Toronto every year, using the Internet as the main tool of communication.The pilot study explored the different methods that can be used to provide real-time interactive remote education, and delivered traditional classroom lectures as well as hands-on workshops.Another similar project was started in 2007 to offer real-time teaching to a class of medical physics students at Wuhan University in Hubei, China. There are new challenges as well as new opportunities associated with this project. By building an inventory of tools and experiences, the intent is to broaden the real-time teleteaching method to serve a wide community so that future students entering the field can have efficient access to high-quality education that will benefit the profession in the long term.
  6. Nizam M, Ng Kh, Abdullah B
    Biomed Imaging Interv J, 2006 Jul;2(3):e38.
    PMID: 21614246 MyJurnal DOI: 10.2349/biij.2.3.e38
    The accuracy and the efficacy of radiological diagnosis depend, to a large extent, on the conditions under which radiographs and images are viewed. This mainly involves the luminance of the display devices and the ambient room illumination. We report a perceptual study to investigate the relationship between detectability and monitor luminance as well as ambient illuminance. A statistical test pattern was used in this study, and the test pattern was developed using Microsoft® Visual Basic 6. The test pattern contained a set of randomised contrast detail objects, that is, disks of different diameters (0.7, 1.0, 1.4, and 2.0 mm) and contrasts against a black background (2.7, 3.9, 5.5, and 7.8%), simulating lesions in digital images. The receiver operating characteristic (ROC) analysis was used in this study. The results indicated that a set of optimal viewing conditions exists and that it has a significant effect on detectability performance.
  7. Ramanaidu S, Sta Maria R, Ng Kh, George J, Kumar G
    Biomed Imaging Interv J, 2006 Jul;2(3):e35.
    PMID: 21614244 MyJurnal DOI: 10.2349/biij.2.3.e35
    A study of radiation dose and image quality following changes to the tube potential (kVp) in paediatric chest radiography.
  8. Bhugaloo A, Abdullah B, Siow Y, Ng Kh
    Biomed Imaging Interv J, 2006 Apr;2(2):e12.
    PMID: 21614224 MyJurnal DOI: 10.2349/biij.2.2.e12
    The primary objective of this study was to evaluate the specificity and sensitivity of diffusion weighted MR imaging (DWI) in the differentiation and characterisation between benign and malignant vertebral compression fractures compared with conventional T1 WI, T2 WI and fat suppressed contrast enhanced T1 WI in the Malaysian population.
  9. Faridah Y, Abdullah B, Ng Kh
    Biomed Imaging Interv J, 2005 Jul;1(1):e3.
    PMID: 21625275 DOI: 10.2349/biij.1.1.e3
    The single emulsion or single screen system is usually reserved for mammography since its use in general radiography is limited. The purpose of this study is to compare the mammographic film-screen combination (MFC) and the standard film-screen combination (SFC) in terms of fracture and soft tissue injuries detection. PATIENTS, METHODS AND MATERIALS: In this prospective study, 41 patients from Accident and Emergency suspected of having injury in the hands, wrists, ankles and feet regions were radiographed using both MFC and SFC. These were compared in terms of image quality, presence of fractures and soft tissue injuries. The two different film-screen combinations were also compared in terms of detection of bony fragments, film characteristics such as film speed, contrast and spatial resolution, dose and cost.
  10. Lam S, Bux S, Kumar G, Ng Kh, Hussain A
    Biomed Imaging Interv J, 2009 Jul;5(3):e13.
    PMID: 21611051 MyJurnal DOI: 10.2349/biij.5.3.e13
    To compare the image quality of the low-dose to the standard-dose protocol of MDCT scanning of the paranasal sinuses, based on subjective assessment and determine the radiation doses to the eyes and thyroid gland and dose reduction between these two protocols.