Displaying publications 61 - 62 of 62 in total

Abstract:
Sort:
  1. Abdul Aziz SA, Mohd Saparudin AK, Harun AZ
    Malays J Med Sci, 2013 May;20(3):23-30.
    PMID: 23966821 MyJurnal
    BACKGROUND: Different target-filter combinations in computed radiography have different impacts on the dose and image quality in digital radiography. This study aims to evaluate the mean glandular dose (MGD) and modulation transfer function (MTF) of various target-filter combinations by investigating the signal intensities of X-ray beams.

    METHODS: General Electric (GE) Senographe DMR Plus mammography unit was used for MGD and MTF evaluation. The measured MGD was compared with the dose reference level (DRL), whereas the MTF was evaluated using ImageJ 1.46o software. A modified Mammography Accreditation Phantom RMI 156 was exposed using different target-filter combinations of molybdenum-molybdenum (Mo-Mo), molybdenum-rhodium (Mo-Rh) and rhodium-rhodium (Rh-Rh) at two different tube voltages, 26 kV and 32 kV with 50 mAs.

    RESULTS: In the MGD evaluations, all target-filters gave an MGD value of < 1.5 mGy. The one-way ANOVA test showed a highly significant interaction between the MGD and the kilovoltage and target-filter material used (26 kV: F (2,12) = 49,234, P = 0.001;32 kV: F (2,12) = 89,972, P = 0.001). A Tukey post-hoc test revealed that the MGD for 26 kV and 32 kV was highly affected by the target-filter combinations. The test of homogeneity of variances indicates that the MGD varies significantly for 26 kV and 32 kV images (0.045 and 0.030 (P < 0.05), respectively). However, the one-way ANOVA for the MTF shows that no significant difference exists between the target-filter combinations used with 26 kV and 32 kV images either in parallel or perpendicular to the chest wall side F (2,189) = 0.26, P > 0.05).

    CONCLUSION: Higher tube voltage and atomic number target-filter yield higher MGD values. However, the MTF is independent of the X-ray energy and the type of target-filter combinations used.

  2. Abd Majid N, Rainis R, Sahani M, Mohamed AF, Abdul Ghani Aziz SA, Muhamad Nazi N
    Geospat Health, 2021 03 11;16(1).
    PMID: 33706498 DOI: 10.4081/gh.2021.915
    In recent decades, dengue outbreaks have become increasingly common around the developing countries, including Malaysia. Thus, it is essential for rural as well as urbanised livelihood to understand the distribution pattern of this infection. The objective of this study is to determine the trend of dengue cases reported from the year 2014 to 2018 and the spatial pattern for this spread. Spatial statistical analyses conducted found that the distribution pattern and spatial mean centre for dengue cases were clustered in the eastern part of the Bangi region. Directional distribution observed that the elongated polygon of dengue cluster stretched from the Northeast to the Southwest of Bangi District. The standard distance observed for dengue cases was smallest in the year 2014 (0.017 m), and largest in 2016 (0.019 m), whereas in the year 2015, 2017 and 2018, it measured 0.018 m. The average nearest neighbour analysis also displayed clustered patterns for dengue cases in the Bangi District. The three spatial statistical analyses (spatial mean centre, standard distance and directional distribution) findings illustrate that the dengue cases from the year 2014 to 2018 are clustered in the Northeast to the Southwest of the study region.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links