Displaying all 6 publications

Abstract:
Sort:
  1. Alkhorayef M, Sulieman A, Barakat H, Al-Mohammed HI, Theodorou K, Kappas C, et al.
    Saudi J Biol Sci, 2021 Jan;28(1):35-39.
    PMID: 33424280 DOI: 10.1016/j.sjbs.2020.08.026
    Medical exposure of the general population due to radiological investigations is the foremost source of all artificial ionising radiation. Here, we focus on a particular diagnostic radiological procedure, as only limited data are published with regard to radiation measurements during urethrograpic imaging. Specifically, this work seeks to estimate patient and occupational effective doses during urethrographic procedures at three radiology hospitals. Both staff and patient X-ray exposure levels were calculated in terms of entrance surface air kerma (ESAK), obtained by means of lithium fluoride thermoluminescent dosimeters (TLD-100(LiF:Mg:Cu.P)) for 243 urethrographic examinations. Patient radiation effective doses per procedure were estimated using conversion factors obtained from the use of Public Health England computer software. In units of mGy, the median and range of ESAK per examination were found to be 10.8 (3.6-26.2), 7.0 (0.2-32.3), and 24.3 (9.0-32.0) in Hospitals A, B, and C, respectively. The overall mean and range of staff doses (in µGy) were found to be 310 (4.0-1750) per procedure. With the exception of hospital C, the present evaluations of radiation dose have been found to be similar to those of previously published research. The wide range of patient and staff doses illustrate the need for radiation dose optimisation.
  2. Sulieman A, Mayhoub FH, Salah H, Al-Mohammed HI, Alkhorayef M, Moftah B, et al.
    Appl Radiat Isot, 2020 Oct;164:109240.
    PMID: 32819499 DOI: 10.1016/j.apradiso.2020.109240
    Lutetium-177 (DOTATATE) (177Lu; T1/2 6.7 days), a labelled β- and Auger-electron emitter, is widely used in treatment of neuroendocrine tumours. During performance of the procedure, staff and other patients can potentially receive significant doses in interception of the gamma emissions [113 keV (6.4%) and 208 keV (11%)] that are associated with the particle decays. While radiation protection and safety assessment are required in seeking to ensure practices comply with international guidelines, only limited published studies are available. The objectives of present study are to evaluate patient and occupational exposures, measuring ambient doses and estimating the radiation risk. The results, obtained from studies carried out in Riyadh over an 11 month period, at King Faisal Specialist Hospital and Research Center, concerned a total of 33 177Lu therapy patients. Patient exposures were estimated using a calibrated Victoreen 451P survey meter (Fluke Biomedical), for separations of 30 cm, 100 cm and 300 cm, also behind a bed shield that was used during hospitalization of the therapy patients. Occupational and ambient doses were also measured through use of calibrated thermoluminescent dosimeters and an automatic TLD reader (Harshaw 6600). The mean and range of administered activity (in MBq)) was 7115.2 ± 917.2 (4329-7955). The ambient dose at corridors outside of therapy isolation rooms was 1.2 mSv over the 11 month period, that at the nursing station was below the limit of detection and annual occupational doses were below the annual dose limit of 20 mSv. Special concern needs to be paid to comforters (carers) and family members during the early stage of radioisotope administration.
  3. Alkhorayef M, Sulieman A, Mohamed-Ahmed M, Al-Mohammed HI, Alkhomashi N, Sam AK, et al.
    Appl Radiat Isot, 2018 Nov;141:270-274.
    PMID: 30145016 DOI: 10.1016/j.apradiso.2018.07.014
    With associated cure rates in excess of 90%, targeted 131I radioactive iodine therapy has clearly improved thyroid cancer survival. Thus said, potential radiation risks to staff represent a particular concern, current study seeking to determine the radiation exposure of staff from 131I patients during hospitalization, also estimating accumulated dose and related risk to staff during preparation of the radioactive iodine. In present study made over the three-month period 1st February to 1st May 2017, a total of 69 patient treatments were investigated (comprising a cohort of 46 females and 23 males), this being a patient treatment load typically reflective of the workload at the particular centre for such treatments. The patients were administered sodium iodide 131I, retained in capsules containing activities ranging from 370 to 5550 MBq at the time of calibration, radioiodine activity depends on many factors such as gender, clinical indication, body mass index and age. The staff radiation dose arising from each patient treatment was measured on three consecutive days subsequent to capsule administration. In units of µSv, the mean and dose-rates range at distances from the patients of 5 cm, 1 m and 2 m were 209 ± 73 (165-294), 6.8 ± 2 (5.3-9.5) and 0.9 ± 0.3 (0.7-1.2). The annual dose (also measured in units of µSv), based on annual records of doses, for medical physicists, technologists and nurses were 604, 680 and 1000 µSv respectively. In regard to current practice and workload, staff exposures were all found to be below the annual dose limit for radiation workers.
  4. Salah H, Al-Mohammed HI, Mayhoub FH, Sulieman A, Alkhorayef M, Abolaban FA, et al.
    Radiat Prot Dosimetry, 2021 Oct 12;195(3-4):349-354.
    PMID: 34144608 DOI: 10.1093/rpd/ncab077
    This study has sought to evaluate patient exposures during the course of particular diagnostic positron emission tomography and computed tomography (PET/CT) techniques. A total of 73 patients were examined using two types of radiopharmaceutical: 18F-fluorocholine (FCH, 48 patients) and 68Ga-prostate-specific membrane antigen (PSMA, 25 patients). The mean and range of administered activity (AA) in MBq, and effective dose (mSv) for FCH were 314.4 ± 61.6 (462.5-216.8) and 5.9 ± 1.2 (8.8-4.11), respectively. Quoted in the same set of units, the mean and range of AA and effective dose for 68Ga-PSMA were 179.3 ± 92.3 (603.1-115.1) and 17.9 ± 9.2 (60.3-11.5). Patient effective doses from 18F-FCH being a factor of two greater than the dose resulting from 68Ga-PSMA PET/CT procedures. CT accounts for some 84 and 23% for 18F-FCH and 68Ga-PSMA procedures, accordingly CT acquisition parameter optimization is recommended. Patient doses have been found to be slightly greater than previous studies.
  5. Sulieman A, Mayhoub F, Ibrahim HS, Omer H, Alkhorayef M, Abolaban FA, et al.
    Radiat Prot Dosimetry, 2021 Oct 12;195(3-4):314-318.
    PMID: 34265851 DOI: 10.1093/rpd/ncab107
    The objective of this study is to estimate the annual effective dose for cardiologists and nurses by measuring Hp(10) and Hp(0.07) during cardiac catheterization procedures. A total of 16 staffs members were working in interventional cardiology during 1 year at a tertiary hospital. The occupational dose was measured using calibrated thermo-luminescent dosemeters (TLD-100, LiF:Mg,Ti). The overall mean and range of the annual Hp(10) and Hp(0.07) (mSv) for cardiologists were 3.7 (0.13-14.5) and 3.2 (0.21-14.7), respectively. Cardiologists were frequently exposed to higher doses compared with nurses and technologists. The exposure showed wide variations, which depend on occupation and workload. Staff is adhered to radiation protection guidelines regarding shielding the trunk, thyroid shield, thus appropriately protected. Lens dose measurement is recommended to ensure that dose limit is not exceeded.
  6. Al-Mohammed HI, Sulieman A, Mayhoub FH, Salah H, Lagarde C, Alkhorayef M, et al.
    Sci Rep, 2021 Jul 15;11(1):14557.
    PMID: 34267237 DOI: 10.1038/s41598-021-93342-1
    Worldwide, thyroid cancer accounts for some 10% of total cancer incidence, most markedly for females. Thyroid cancer radiotherapy, typically using 131I (T1/2 8.02 days; β- max energy 606 keV, branching ratio 89.9%), is widely adopted as an adjunct to surgery or to treat inoperable cancer and hyperthyroidism. With staff potentially receiving significant doses during source preparation and administration, radiation protection and safety assessment are required in ensuring practice complies with international guidelines. The present study, concerning a total of 206 patient radioiodine therapies carried out at King Faisal Specialist Hospital and Research Center over a 6-month period, seeks to evaluate patient and occupational exposures during hospitalization, measuring ambient doses and estimating radiation risk. Using calibrated survey meters, patient exposure dose-rate estimates were obtained at a distance of 30-, 100- and 300 cm from the neck region of each patient. Occupational and ambient doses were measured using calibrated thermoluminescent dosimeters. The mean and range of administered activity (AA, in MBq) for the thyroid cancer and hyperthyroidism treatment groups were 4244 ± 2021 (1669-8066), 1507.9 ± 324.1 (977.9-1836.9), respectively. The mean annual occupational doses were 1.2 mSv, that for ambient doses outside of the isolation room corridors were found to be 0.2 mSv, while ambient doses at the nursing station were below the lower limit of detection. Exposures to staff from patients being treated for thyroid cancer were less compared to hyperthyroidism patients. With a well-defined protocol, also complying with international safety requirements, occupational exposures were found to be relatively high, greater than most reported in previous studies.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links