Many controllers are available in the market for controlling the Permanent Magnet Synchronous Motor (PMSM) drive application, though the most preferably used one is Proportional Integral (PI), controller. However, it is found that the PI and other latest controllers have their own merits and demerits while analyzing their outputs via comparison. Thus it is decided to test the deed of hybrid controllers that can serve a lot better than standalone controllers for precise control applications. In this article, a conventional PI controller has been applied in closed-loop system in combination with recent controllers like Proportional Resonant Controller (PRC), Fractional order Proportional Integral Derivative (FOPID), Hysteresis Current Controller (HCC) and Fuzzy Logic Controller (FLC). The resultant hybrid controllers were (i) PI-FOPID (ii) PI-FLC (iii) FOPID-FLC (iv) HCC-FLC and (v) PRC-FLC. All these hybrid controllers are designed using MATLAB platform and the speed and torque responses are compared to allocate the better performance award to the hybrid controllers. The continuous and intermittent loads are considered while registering time-domain response of PMSM-Pump application. With the aid of time-domain response and THD, the topology to be tested in prototype is chosen and tested for resemblance of the speed response with the simulation output. PI-FLC hybrid controller tends to render optimum performance characteristics among all the other hybrid controllers and the same is validated in real time through hardware results.