Displaying publications 1 - 20 of 27 in total

Abstract:
Sort:
  1. Amini H, Farzaneh B, Azimifar F, Sarhan AAD
    ISA Trans, 2016 Sep;64:293-302.
    PMID: 27329852 DOI: 10.1016/j.isatra.2016.05.006
    This paper establishes a novel control strategy for a nonlinear bilateral macro-micro teleoperation system with time delay. Besides position and velocity signals, force signals are additionally utilized in the control scheme. This modification significantly improves the poor transparency during contact with the environment. To eliminate external force measurement, a force estimation algorithm is proposed for the master and slave robots. The closed loop stability of the nonlinear micro-micro teleoperation system with the proposed control scheme is investigated employing the Lyapunov theory. Consequently, the experimental results verify the efficiency of the new control scheme in free motion and during collision between the slave robot and the environment of slave robot with environment, and the efficiency of the force estimation algorithm.
  2. Bouafassa A, Rahmani L, Mekhilef S
    ISA Trans, 2015 Mar;55:267-74.
    PMID: 25457043 DOI: 10.1016/j.isatra.2014.10.004
    This paper presents a real time implementation of the single-phase power factor correction (PFC) AC-DC boost converter. A combination of higher order sliding mode controller based on super twisting algorithm and predictive control techniques are implemented to improve the performance of the boost converter. Due to the chattering effects, the higher order sliding mode control (HOSMC) is designed. Also, the predictive technique is modified taking into account the large computational delays. The robustness of the controller is verified conducting simulation in MATLAB, the results show good performances in both steady and transient states. An experiment is conducted through a test bench based on dSPACE 1104. The experimental results proved that the proposed controller enhanced the performance of the converter under different parameters variations.
  3. Fayek HM, Elamvazuthi I, Perumal N, Venkatesh B
    ISA Trans, 2014 Sep;53(5):1583-91.
    PMID: 24962934 DOI: 10.1016/j.isatra.2014.06.001
    A computationally-efficient systematic procedure to design an Optimal Type-2 Fuzzy Logic Controller (OT2FLC) is proposed. The main scheme is to optimize the gains of the controller using Particle Swarm Optimization (PSO), then optimize only two parameters per type-2 membership function using Genetic Algorithm (GA). The proposed OT2FLC was implemented in real-time to control the position of a DC servomotor, which is part of a robotic arm. The performance judgments were carried out based on the Integral Absolute Error (IAE), as well as the computational cost. Various type-2 defuzzification methods were investigated in real-time. A comparative analysis with an Optimal Type-1 Fuzzy Logic Controller (OT1FLC) and a PI controller, demonstrated OT2FLC׳s superiority; which is evident in handling uncertainty and imprecision induced in the system by means of noise and disturbances.
  4. Huda AS, Taib S, Ghazali KH, Jadin MS
    ISA Trans, 2014 May;53(3):717-24.
    PMID: 24593986 DOI: 10.1016/j.isatra.2014.02.003
    Infrared thermography technology is one of the most effective non-destructive testing techniques for predictive faults diagnosis of electrical components. Faults in electrical system show overheating of components which is a common indicator of poor connection, overloading, load imbalance or any defect. Thermographic inspection is employed for finding such heat related problems before eventual failure of the system. However, an automatic diagnostic system based on artificial neural network reduces operating time, human efforts and also increases the reliability of system. In the present study, statistical features and artificial neural network (ANN) with confidence level analysis are utilized for inspection of electrical components and their thermal conditions are classified into two classes namely normal and overheated. All the features extracted from images do not produce good performance. Features having low performance reduce the diagnostic performance. The study reveals the performance of each feature individually for selecting the suitable feature set. In order to find the individual feature performance, each feature of thermal image was used as input for neural network and the classification of condition types were used as output target. The multilayered perceptron network using Levenberg-Marquardt training algorithm was used as classifier. The performances were determined in terms of percentage of accuracy, specificity, sensitivity, false positive and false negative. After selecting the suitable features, the study introduces the intelligent diagnosis system using suitable features as inputs of neural network. Finally, confidence percentage and confidence level were used to find out the strength of the network outputs for condition monitoring. The experimental result shows that multilayered perceptron network produced 79.4% of testing accuracy with 43.60%, 12.60%, 21.40, 9.20% and 13.40% highest, high, moderate, low and lowest confidence level respectively.
  5. Ibrahim S, Yunus MA, Green RG, Dutton K
    ISA Trans, 2012 Nov;51(6):821-6.
    PMID: 22624831 DOI: 10.1016/j.isatra.2012.04.010
    Optical tomography provides a means for the determination of the spatial distribution of materials with different optical density in a volume by non-intrusive means. This paper presents results of concentration measurements of gas bubbles in a water column using an optical tomography system. A hydraulic flow rig is used to generate vertical air-water two-phase flows with controllable bubble flow rate. Two approaches are investigated. The first aims to obtain an average gas concentration at the measurement section, the second aims to obtain a gas distribution profile by using tomographic imaging. A hybrid back-projection algorithm is used to calculate concentration profiles from measured sensor values to provide a tomographic image of the measurement cross-section. The algorithm combines the characteristic of an optical sensor as a hard field sensor and the linear back projection algorithm.
  6. Lau CK, Heng YS, Hussain MA, Mohamad Nor MI
    ISA Trans, 2010 Oct;49(4):559-66.
    PMID: 20667537 DOI: 10.1016/j.isatra.2010.06.007
    The performance of a chemical process plant can gradually degrade due to deterioration of the process equipment and unpermitted deviation of the characteristic variables of the system. Hence, advanced supervision is required for early detection, isolation and correction of abnormal conditions. This work presents the use of an adaptive neuro-fuzzy inference system (ANFIS) for online fault diagnosis of a gas-phase polypropylene production process with emphasis on fast and accurate diagnosis, multiple fault identification and adaptability. The most influential inputs are selected from the raw measured data sets and fed to multiple ANFIS classifiers to identify faults occurring in the process, eliminating the requirement of a detailed process model. Simulation results illustrated that the proposed method effectively diagnosed different fault types and severities, and that it has a better performance compared to a conventional multivariate statistical approach based on principal component analysis (PCA). The proposed method is shown to be simple to apply, robust to measurement noise and able to rapidly discriminate between multiple faults occurring simultaneously. This method is applicable for plant-wide monitoring and can serve as an early warning system to identify process upsets that could threaten the process operation ahead of time.
  7. Nagi F, Ahmed SK, Zularnain AT, Nagi J
    ISA Trans, 2011 Jul;50(3):364-75.
    PMID: 21353218 DOI: 10.1016/j.isatra.2011.01.014
    The motivation behind this paper is to seek alternative techniques to achieve a near optimal controller for non-linear systems without solving the analytical problem. In classical optimal control systems, the system states and optimization co-state parameters generate a two-point boundary value problem (TPBVP) using Pontryagin's minimum principle (PMP). The paper contributes a new fuzzy time-optimal controller to the existing fuzzy controllers which has two regular inputs and one bang-bang output. The proposed controller closely approximates the output of the classical time-optimal controller. Further, input membership function are tuned on-line to improve the time-optimal output. The new controller exhibits optimal behaviour for second order non-linear systems. The rules are selected to satisfy the stability and optimality conditions of the new fuzzy time-optimal controller. The paper describes a systematic procedure to design the controller and how to achieve the desired result. To benchmark the new controller performance, a sliding mode controller is used for guidance and comparison purpose. Simulation of three non-linear examples shows promising results. The work described here is expected to incite researcher's interest in fuzzy time-optimal controller design.
  8. Wibowo TC, Saad N
    ISA Trans, 2010 Jul;49(3):335-47.
    PMID: 20304404 DOI: 10.1016/j.isatra.2010.02.005
    This paper discusses the empirical modeling using system identification technique with a focus on an interacting series process. The study is carried out experimentally using a gaseous pilot plant as the process, in which the dynamic of such a plant exhibits the typical dynamic of an interacting series process. Three practical approaches are investigated and their performances are evaluated. The models developed are also examined in real-time implementation of a linear model predictive control. The selected model is able to reproduce the main dynamic characteristics of the plant in open-loop and produces zero steady-state errors in closed-loop control system. Several issues concerning the identification process and the construction of a MIMO state space model for a series interacting process are deliberated.
  9. Abdul Rahim R, Leong LC, Chan KS, Rahiman MH, Pang JF
    ISA Trans, 2008 Jan;47(1):3-14.
    PMID: 17709106
    This paper presents the implementing multiple fan beam projection technique using optical fibre sensors for a tomography system. From the dynamic experiment of solid/gas flow using plastic beads in a gravity flow rig, the designed optical fibre sensors are reliable in measuring the mass flow rate below 40% of flow. Another important matter that has been discussed is the image processing rate or IPR. Generally, the applied image reconstruction algorithms, the construction of the sensor and also the designed software are considered to be reliable and suitable to perform real-time image reconstruction and mass flow rate measurements.
  10. Abdul Rahim R, Pang JF, Chan KS, Leong LC, Sulaiman S, Abdul Manaf MS
    ISA Trans, 2007 Apr;46(2):131-45.
    PMID: 17367791
    The data distribution system of this project is divided into two types, which are a Two-PC Image Reconstruction System and a Two-PC Velocity Measurement System. Each data distribution system is investigated to see whether the results' refreshing rate of the corresponding measurement can be greater than the rate obtained by using a single computer in the same measurement system for each application. Each system has its own flow control protocol for controlling how data is distributed within the system in order to speed up the data processing time. This can be done if two PCs work in parallel. The challenge of this project is to define the data flow process and critical timing during data packaging, transferring and extracting in between PCs. If a single computer is used as a data processing unit, a longer time is needed to produce a measurement result. This insufficient real-time result will cause problems in a feedback control process when applying the system in industrial plants. To increase the refreshing rate of the measurement result, an investigation on a data distribution system is performed to replace the existing data processing unit.
  11. Lotfivand N, Abdolzadeh V, Hamidon MN
    ISA Trans, 2016 Jul;63:425-435.
    PMID: 27038885 DOI: 10.1016/j.isatra.2016.03.012
    Numerous applications of artificial olfaction resulting from research in many branches of sciences have caused considerable interest in the enhancement of these systems. In this paper, we offer an architecture which is suitable for critical applications, such as medical diagnosis, where reliability and precision are deemed important. The proposed architecture is able to tolerate failures in the sensors of the array. In this study, the discriminating ability of the proposed architecture in detecting complex odors, as well as the performance of the proposed architecture in encountering sensor failure, were investigated and compared with the generic architecture. The results demonstrated that by applying the proposed architecture in the artificial olfactory system, the performance of system in the healthy mode was identical to the classic structure. However, in the faulty situation, the proposed architecture implied high identification ability of odor samples, while the generic architecture showed very poor performance in the same situation. Based on the results, it was possible to achieve high odor identification through the developed artificial olfactory system using the proposed architecture.
  12. Ibrahim S, Green RG, Dutton K, Abdul Rahim R
    ISA Trans, 2002 Jan;41(1):13-8.
    PMID: 12014798
    This paper describes a system using lensed optical fiber sensors that are arranged in the form of two orthogonal projections. The sensors are placed around a process vessel for upstream and downstream measurements. The purpose of the system is for on-line monitoring of particles and droplets being conveyed by a fluid. The lenses were constructed using a custom heating fixture. The fixture enables the lenses to be constructed with similar radii resulting in identical characteristics with minimum differences in transmitted intensity and emission angle. By collimating radiation from two halogen bulbs, radiation can be obtained by the sensors with radiation intensity related to the nature of the media. Each sensor interrogates a finite section of the measurement section. Each sensor provides a view. Parallel sensors provide a projection. Signal processing is carried out on the measured data in the time and frequency domains to investigate the latent information present in the flow signals.
  13. Haruna A, Mohamed Z, Efe MÖ, Basri MAM
    ISA Trans, 2020 Feb;97:1-13.
    PMID: 31327468 DOI: 10.1016/j.isatra.2019.07.016
    This paper proposes an improved method of integral backstepping for real time control of a laboratory helicopter with variable speed rotors known as the Two-Rotor Aero-dynamic System (TRAS). The coupled system is decomposed into the horizontal subsystem (HS) and the vertical subsystem (VS) and traditional backstepping, augmented with direct integral action is designed for each subsystem. The transient response to both constant and time varying references is then simultaneously improved by modifying an already proposed method called dual boundary conditional integration. A switching technique is also employed to enhance the tracking response of the undamped HS for its bi-directional motor which exhibits jerking effects. Experimental results show that the proposed approach yields improved transient and tracking performance when compared to previously proposed methods exploiting conditional integration earlier proposed for improving the transient response of controlled nonlinear systems with integral action. The results also show the robustness of the proposed method in the presence of the coupling effects and additional external disturbance applied to the system in the form of a wind gust.
  14. Tarusan SAA, Jidin A, Jamil MLM
    ISA Trans, 2021 Apr 16.
    PMID: 33931170 DOI: 10.1016/j.isatra.2021.04.005
    Direct Torque Control (DTC) scheme introduces a robust and simple control of electrical drive. However, its shortcomings such as broad torque ripple and variable switching frequency have offered several improvements like Space Vector Modulation (SVM) strategy, multilevel inverter (MLI) topology, etc. The conventional DTC which is fed by the two-level inverter has limited voltage vector, results in some difficulties to optimize the operation, especially at low operating speed. In contrast to MLI, the abundant of voltage vector has provided various amplitudes and angles that can overcome the problem of conventional DTC. Thus, this paper introduces the selected optimal voltage vector obtained from five-level Cascaded H-Bridge (CHB) inverter that employs in DTC hysteresis-based to achieve better optimization that similar to the DTC-SVM. Initially, the research work begins with an investigation on the performance comparison between a DTC hysteresis-based between two-level inverter (conventional method) and a five-level CHB inverter (proposed method). Here, a DC generator acted as a load is employed to control the operating speed instead of the speed controller (speed controller is negligible). Hence, the DTC method is optimized by minimizing the torque ripple as well as retaining the torque control capability at constant torque region on several operating speed. The selected optimal vector from the look-up table DTC of five-level CHB inverter must be dynamically appropriate to any change of torque (increased or decreased torque). For simplicity, this paper will only discuss the experimental results for both topologies of drive system. From the experimental results, it is verified that the torque ripples by the proposed method have achieved 10% and 50% reduction at high and low operating speed respectively. It is found that the DTC hysteresis-based result simpler control method than DTC-SVM while maintaining similar output performance.
  15. Priyanka S, Sakthivel R, Mohanapriya S, Kong F, Saat S
    ISA Trans, 2021 Jun 22.
    PMID: 34217497 DOI: 10.1016/j.isatra.2021.06.022
    This paper investigates the issue of fault-tolerant and anti-disturbance attenuation for a two-dimensional modified repetitive control system (2D MRCS) which is described by switched fuzzy systems with multiple disturbances. In particular, the multiple disturbances contain an exogenous disturbance and standard Wiener noise. Specifically, a generalized extended state observer (GESO) is incorporated with the 2D MRCS to estimate both fault and exogenous multiple disturbances so that the disturbances and faults can be attenuated in the control input. Further, the improved 2D MRCS relaxes the stability condition and provides an enhanced tracking performance. Based on the Lyapunov function approach, pole placement technique and average dwell time approach, the stability criteria for the considered system is developed in terms of linear matrix inequality (LMI). Then an algorithm for designing a GESO-based 2D MRC design is developed based on the obtained LMIs. Further, the results developed are validated in the simulation section through three numerical examples.
  16. Ganapathee M, Alavandar S, Kasinathan P, Sowmmiya U, Ramachandaramurthy VK, Pachaivannan N
    ISA Trans, 2021 Sep 03.
    PMID: 34531058 DOI: 10.1016/j.isatra.2021.09.001
    Many controllers are available in the market for controlling the Permanent Magnet Synchronous Motor (PMSM) drive application, though the most preferably used one is Proportional Integral (PI), controller. However, it is found that the PI and other latest controllers have their own merits and demerits while analyzing their outputs via comparison. Thus it is decided to test the deed of hybrid controllers that can serve a lot better than standalone controllers for precise control applications. In this article, a conventional PI controller has been applied in closed-loop system in combination with recent controllers like Proportional Resonant Controller (PRC), Fractional order Proportional Integral Derivative (FOPID), Hysteresis Current Controller (HCC) and Fuzzy Logic Controller (FLC). The resultant hybrid controllers were (i) PI-FOPID (ii) PI-FLC (iii) FOPID-FLC (iv) HCC-FLC and (v) PRC-FLC. All these hybrid controllers are designed using MATLAB platform and the speed and torque responses are compared to allocate the better performance award to the hybrid controllers. The continuous and intermittent loads are considered while registering time-domain response of PMSM-Pump application. With the aid of time-domain response and THD, the topology to be tested in prototype is chosen and tested for resemblance of the speed response with the simulation output. PI-FLC hybrid controller tends to render optimum performance characteristics among all the other hybrid controllers and the same is validated in real time through hardware results.
  17. Muthukumar P, Balasubramaniam P, Ratnavelu K
    ISA Trans, 2018 Nov;82:51-61.
    PMID: 28755926 DOI: 10.1016/j.isatra.2017.07.007
    This paper proposes a generalized robust synchronization method for different dimensional fractional order dynamical systems with mismatched fractional derivatives in the presence of function uncertainty and external disturbance by a designing sliding mode controller. Based on the proposed theory of generalized robust synchronization criterion, a novel audio cryptosystem is proposed for sending or sharing voice messages secretly via insecure channel. Numerical examples are given to verify the potency of the proposed theories.
  18. Seer QH, Nandong J
    ISA Trans, 2017 Mar;67:233-245.
    PMID: 28160974 DOI: 10.1016/j.isatra.2017.01.017
    Open-loop unstable systems with time-delays are often encountered in process industry, which are often more difficult to control than stable processes. In this paper, the stabilization by PID controller of second-order unstable processes, which can be represented as second-order deadtime with an unstable pole (SODUP) and second-order deadtime with two unstable poles (SODTUP), is performed via the necessary and sufficient criteria of Routh-Hurwitz stability analysis. The stability analysis provides improved understanding on the existence of a stabilizing range of each PID parameter. Three simple PID tuning algorithms are proposed to provide desired closed-loop performance-robustness within the stable regions of controller parameters obtained via the stability analysis. The proposed PID controllers show improved performance over those derived via some existing methods.
  19. Naderipour A, Abdul-Malek Z, Ramachandaramurthy VK, Kalam A, Miveh MR
    ISA Trans, 2019 Nov;94:352-369.
    PMID: 31078293 DOI: 10.1016/j.isatra.2019.04.025
    This paper proposes an improved hierarchical control strategy consists of a primary and a secondary layer for a three-phase 4-wire microgrid under unbalanced and nonlinear load conditions. The primary layer is comprised of a multi-loop control strategy to provide balanced output voltages, a harmonic compensator to reduce the total harmonic distortion (THD), and a droop-based scheme to achieve an accurate power sharing. At the secondary control layer, a reactive power compensator and a frequency restoration loop are designed to improve the accuracy of reactive power sharing and to restore the frequency deviation, respectively. Simulation studies and practical performance are carried out using the DIgSILENT Power Factory software and laboratory testing, to verify the effectiveness of the control strategy in both islanded and grid-connected mode. Zero reactive power sharing error and zero frequency steady-state error have given this control strategy an edge over the conventional control scheme. Furthermore, the proposed scheme presented outstanding voltage control performance, such as fast transient response and low voltage THD. The superiority of the proposed control strategy over the conventional filter-based control scheme is confirmed by the 2 line cycles decrease in the transient response. Additionally, the voltage THDs in islanded mode are reduced from above 5.1% to lower than 2.7% with the proposed control strategy under nonlinear load conditions. The current THD is also reduced from above 21% to lower than 2.4% in the connection point of the microgrid with the offered control scheme in the grid-connected mode.
  20. Hermansson AW, Syafiie S
    ISA Trans, 2019 Aug;91:66-77.
    PMID: 30782432 DOI: 10.1016/j.isatra.2019.01.037
    This paper investigates a novel offset-free control scheme based on a multiple model predictive controller (MMPC) and an adaptive integral action controller for nonlinear processes. Firstly, the multiple model description captures the essence of the nonlinear process, while keeping the MPC optimization linear. Multiple models also enable the controller to deal with the uncertainty associated with changing setpoint. Then, a min-max approach is utilized to counter the effect of parametric uncertainty between the linear models and the nonlinear process. Finally, to deal with other uncertainties, such as input and output disturbances, an adaptive integral action controller is run in parallel to the MMPC. Thus creating a novel offset-free approach for nonlinear systems that is more easily tuned than observer-based MPC. Simulation results for a pH-controller, which acts as an example of a nonlinear process, are presented to demonstrate the usefulness of the technique compared to using an observer-based MPC.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links