Displaying all 4 publications

Abstract:
Sort:
  1. Musawi A, Ariffin YT
    J Clin Transl Res, 2017 May 24;3(2):271-275.
    PMID: 30873478
    Background: The Condylar Path Angle (CPA) is an important measurement that is used to program articulators used in dental treatment. The purpose of the current study was to investigate the CPA in Malay subjects, to compare the measurements with average values, 25˚-35˚ Camper's (based on Caucasian studies), and to compare the right and left CPAs. Methods: Thirty subjects aged 21-23 years were recruited. A wash technique impression was made, casts were poured, and face-bow transfers were taken. The casts were mounted to their centric position on a semi-adjustable articulator. Protrusive guides were constructed to allow the mandible to be protruded for 5 mm, and then the angles were measured using the protrusive record method. Results: The right CPA was within the normal range for 43% (13/30) of participants and out of the normal range for 57% (17/30). The left CPA was within the normal range for 33% (10/30) of participants and out of the normal range for 67% (19/30). There was no statistically significant difference between the left and right CPAs (p = 0.72), but there was a strong linear relationship between left and right CPAs (p = 0.001). Conclusions: Results of the current study indicated Malay subjects had measurable variations in the CPA, suggesting this population has an ethnic variation in the CPA. Relevance for patients: To improve the quality of patient care, the CPA should be considered when constructing fixed/removable prostheses that use semi-adjustable articulators, and clinicians should not rely on the set average values that are pre-set on articulators.
  2. Buzayan MM, Ariffin YT, Yunus N
    J Prosthodont, 2013 Oct;22(7):591-5.
    PMID: 23551843 DOI: 10.1111/jopr.12036
    A method is described for the fabrication of a closed hollow bulb obturator prosthesis using a hard thermoforming splint material and heat-cured acrylic resin. The technique allowed the thickness of the thermoformed bulb to be optimized for weight reduction, while the autopolymerized seal area was covered in heat-cured acrylic resin, thus eliminating potential leakage and discoloration. This technique permits the obturator prosthesis to be processed to completion from the wax trial denture without additional laboratory investing, flasking, and processing.
  3. Buzayan MM, Ariffin YT, Yunus N, Mahmood WA
    J Prosthodont, 2015 Aug;24(6):506-10.
    PMID: 25315047 DOI: 10.1111/jopr.12235
    Ocular disorders occasionally necessitate surgical intervention that may lead to eye defects. The primary objective in restoring and rehabilitating such defects with an ocular prosthesis is to enable patients to cope better with associated psychological stress and to return to their accustomed lifestyle. A series of detailed steps for custom-made ocular prosthesis fabrication using the advantages of digital photography to replace the conventional oil paint and monopoly iris painting technique are presented in this article. In the present case, a digital photograph of the patient's iris was captured using a digital camera and manipulated on a computer using graphic software to produce a replica of the natural iris. The described technique reduces treatment time, increases simplicity, and permits the patient's natural iris to be replicated without the need for iris painting and special artistic skills.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links