MATERIALS AND METHODS: A cross-sectional study was carried out among 51 cleaners. The respondents' background information and respiratory symptoms were gathered using a series of standardised questionnaires validated by the American Thoracic Society (ATS-DLD-78-A). The 8- hour respirable dust exposure to cleaners was measured using an air sampling pump (Gillian & Sensodyne Gil Air 3).
RESULTS: The mean of respirable dust was lower than permissible exposure limit with 0.63±0.57mg/m3. The respiratory symptoms among the cleaners showed no significant association between cough, phlegm, and breathing difficulties with working tenure. Meanwhile, wheezing and coughing with phlegm have an almost significant association with working tenure among cleaners with (Χ2=1.00, p=0.08) and (Χ2=1.00, p=0.07) respectively. Exposure to respirable dust has exhibited 6 times the prevalence of coughing with phlegm among cleaners (PR=6.28, 95% CI: 0.44, 89.38).
CONCLUSION: The findings of this study demonstrated that the cleaners were significantly affected by the respirable dust. The cleaners' working environment has caused them to be exposed to respirable dust.