Displaying all 2 publications

Abstract:
Sort:
  1. Mustafar R, Nesam T, Kamaruzaman L, Mohd R, Sukor N, Safian N, et al.
    Med J Malaysia, 2023 Jan;78(1):87-92.
    PMID: 36715197
    INTRODUCTION: Low serum 25-hydroxyvitamin D is associated with chronic kidney disease progression, and there are limited data on the vitamin D levels in patients with Immunoglobulin A nephropathy. This study was conducted to determine the level of 25-hydroxyvitamin D in a stable immunoglobulin A nephropathy patient and its association with other parameters.

    MATERIALS AND METHODS: We performed a cross-sectional study involving 70 patients with biopsy-proven immunoglobulin A nephropathy with a stable estimated glomerular filtration rate and urinary albuminuria. Their demographic profiles were documented, and blood samples were taken for serum 25-hydroxyvitamin D, highly sensitive C-reactive protein, urine albuminuria and other routine blood tests.

    RESULTS: We found nine patients (12.9%) had sufficient 25- hydroxyvitamin D [25(OH)D] levels of more than 30ng/mL and the rest of the patients; 61 (87.1%) had serum 25(OH)D levels below 30 ng/ml. Amongst those with low vitamin D, 38 (62.3%) had serum 25(OH)D between 15-30 ng/mL (insufficient), and the remaining 23 (37.7%) had serum 25(OH)D below 15 ng/ml (deficient). Their mean level of serum 25(OH)D was 19.92 ± 9.04 ng/mL with a serum creatinine of 106.23 ± 38.56 μmol/L and mean estimated glomerular filtration rate (eGFR) at 68.11± 27.65 mL/min/1.73 m2. There was no association between urinary albuminuria, highly sensitive C-reactive protein, estimated glomerular filtration rate or systolic blood pressure with serum 25(OH)D level.

    CONCLUSION: Low vitamin D (insufficiency and deficiency) are indeed prevalent in stable immunoglobulin A nephropathy patients. We found no correlation between the vitamin D levels with albuminuria, renal function and highly sensitive C-reactive.

  2. Mamat R, Kong NC, Ba'in A, Shah SA, Cader R, Wong V, et al.
    J Clin Nurs, 2012 Oct;21(19-20):2879-85.
    PMID: 22646855 DOI: 10.1111/j.1365-2702.2012.04091.x
    The main objective of the study was to correlate the target dry weight in haemodialysis (HD) patients as assessed clinically by nephrologists to those measured by the Body Composition Monitor (BCM - Fresenius) machine. The second objective was to compare pre and postdialysis changes of extracellular fluid and clinical parameters.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links