Displaying all 2 publications

Abstract:
Sort:
  1. Vejayakumaran P, Rahman IA, Sipaut CS, Ismail J, Chee CK
    J Colloid Interface Sci, 2008 Dec 1;328(1):81-91.
    PMID: 18822418 DOI: 10.1016/j.jcis.2008.08.054
    Grafting of free maleimide and epoxide pendant groups onto the surface of approximately 7-nm silica nanoparticles was investigated. Glycidyloxypropyl groups (3-glycidyloxypropyltrimethoxysilane and 3-aminopropyltrimethoxysilane) that carried epoxide groups and aminopropyl groups were grafted to the silica surface with the help of condensation reactions. Maleimide groups [1,1(')-(methylenedi-4,1-phenelene) bismaleimide] were introduced to the silica surface via nucleophilic addition reaction with the aminopropyl groups pre-grafted onto the surface. The grafted silica samples were characterized using CHN, FTIR, DSC, TGA-FTIR, and 13C and 29Si CP/MAS NMR spectroscopy. NMR analyses revealed that all the functional groups were covalently bonded to the silica surface and most of the maleimide and epoxide rings remained intact on surface. DSC analysis showed that the epoxide groups were more reactive than the maleimide groups.
  2. Wong EY, Chew PT, Chee CK, Wong JS
    Am J Ophthalmol, 1997 Dec;124(6):797-804.
    PMID: 9402826
    PURPOSE: To evaluate the effectiveness and safety of diode laser contact transscleral cyclophotocoagulation in Asian patients with refractory glaucoma by lower energy settings with an innovative probe featuring a glass ball tip that focused the laser beam onto the ciliary body.

    METHODS: This prospective clinical study included consecutive Asian patients with dark irides and confirmed for glaucoma. Only one eye of each patient was treated. Diode laser contact transscleral cyclophotocoagulation treatment was performed with the center of the probe placed 1.5 mm behind the limbus. About 30 pulses of 810-mm laser radiation (power, 1.8 to 2.0 W; duration, 0.3 to 0.5 second) were applied around the eye. Patients were examined at fixed postoperative intervals. Intraocular pressure levels and postoperative complications were recorded. The relation between patient and disease characteristics, total laser energy delivered, and intraocular pressure effects were analyzed.

    RESULTS: Thirty-three patients were studied, with a mean follow-up period of 9.4 months. An average 56% of patients showed a 30% or greater drop in intraocular pressure. About 38% of patients achieved sustained intraocular pressure lowering to below 22 mm Hg at 18 months. Complications were few and included transient hypotony and iritis.

    CONCLUSIONS: In Asian patients with refractory glaucoma or painful glaucomatous eyes with poor visual acuity (defined for this study as worse than 20/200), low-energy-setting diode laser contact transscleral cyclophotocoagulation by means of the glass ball probe is relatively effective and safe.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links