Displaying all 5 publications

Abstract:
Sort:
  1. Chow LS, Rajagopal H
    Magn Reson Imaging, 2017 11;43:74-87.
    PMID: 28716679 DOI: 10.1016/j.mri.2017.07.016
    An effective and practical Image Quality Assessment (IQA) model is needed to assess the image quality produced from any new hardware or software in MRI. A highly competitive No Reference - IQA (NR - IQA) model called Blind/Referenceless Image Spatial Quality Evaluator (BRISQUE) initially designed for natural images were modified to evaluate structural MR images. The BRISQUE model measures the image quality by using the locally normalized luminance coefficients, which were used to calculate the image features. The modified-BRISQUE model trained a new regression model using MR image features and Difference Mean Opinion Score (DMOS) from 775 MR images. Two types of benchmarks: objective and subjective assessments were used as performance evaluators for both original and modified-BRISQUE models. There was a high correlation between the modified-BRISQUE with both benchmarks, and they were higher than those for the original BRISQUE. There was a significant percentage improvement in their correlation values. The modified-BRISQUE was statistically better than the original BRISQUE. The modified-BRISQUE model can accurately measure the image quality of MR images. It is a practical NR-IQA model for MR images without using reference images.
  2. Chow LS, Paley MNJ
    Magn Reson Imaging, 2021 06;79:76-84.
    PMID: 33753137 DOI: 10.1016/j.mri.2021.03.014
    The optic nerve is known to be one of the largest nerve bundles in the human central nervous system. There have been many studies of optic nerve imaging and post-processing that have provided insights into pathophysiology of optic neuritis related to multiple sclerosis and neuromyelitis optica spectrum disorder, glaucoma, and Leber's hereditary optic neuropathy. There are many challenges in optic nerve imaging, due to the morphology of the nerve through its course to the optic chiasm, its mobility due to eye movements and the high signal from cerebrospinal fluid and orbital fat surrounding the optic nerve. Recently, many advanced and fast imaging sequences have been used with post-processing techniques in attempts to produce higher resolution images of the optic nerve for evaluating various diseases. Magnetic resonance imaging (MRI) is one of the most common imaging methodologies for the optic nerve. This review paper will focus on recent MRI advances in optic nerve imaging and explain several post-processing techniques being used for analysis of optic nerve images. Finally, some challenges and potential for future optic nerve studies will be discussed.
  3. Chow LS, Rajagopal H, Paramesran R, Alzheimer's Disease Neuroimaging Initiative
    Magn Reson Imaging, 2016 07;34(6):820-831.
    PMID: 26969762 DOI: 10.1016/j.mri.2016.03.006
    Medical Image Quality Assessment (IQA) plays an important role in assisting and evaluating the development of any new hardware, imaging sequences, pre-processing or post-processing algorithms. We have performed a quantitative analysis of the correlation between subjective and objective Full Reference - IQA (FR-IQA) on Magnetic Resonance (MR) images of the human brain, spine, knee and abdomen. We have created a MR image database that consists of 25 original reference images and 750 distorted images. The reference images were distorted with six types of distortions: Rician Noise, Gaussian White Noise, Gaussian Blur, DCT compression, JPEG compression and JPEG2000 compression, at various levels of distortion. Twenty eight subjects were chosen to evaluate the images resulting in a total of 21,700 human evaluations. The raw scores were then converted to Difference Mean Opinion Score (DMOS). Thirteen objective FR-IQA metrics were used to determine the validity of the subjective DMOS. The results indicate a high correlation between the subjective and objective assessment of the MR images. The Noise Quality Measurement (NQM) has the highest correlation with DMOS, where the mean Pearson Linear Correlation Coefficient (PLCC) and Spearman Rank Order Correlation Coefficient (SROCC) are 0.936 and 0.938 respectively. The Universal Quality Index (UQI) has the lowest correlation with DMOS, where the mean PLCC and SROCC are 0.807 and 0.815 respectively. Student's T-test was used to find the difference in performance of FR-IQA across different types of distortion. The superior IQAs tested statistically are UQI for Rician noise images, Visual Information Fidelity (VIF) for Gaussian blur images, NQM for both DCT and JPEG compressed images, Peak Signal-to-Noise Ratio (PSNR) for JPEG2000 compressed images.
  4. Chow LS, Tang GS, Solihin MI, Gowdh NM, Ramli N, Rahmat K
    SN Comput Sci, 2023;4(2):141.
    PMID: 36624807 DOI: 10.1007/s42979-022-01545-8
    Coronavirus disease 2019 (COVID-19) is a disease caused by a novel strain of coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), severely affecting the lungs. Our study aims to combine both quantitative and qualitative analysis of the convolutional neural network (CNN) model to diagnose COVID-19 on chest X-ray (CXR) images. We investigated 18 state-of-the-art CNN models with transfer learning, which include AlexNet, DarkNet-19, DarkNet-53, DenseNet-201, GoogLeNet, Inception-ResNet-v2, Inception-v3, MobileNet-v2, NasNet-Large, NasNet-Mobile, ResNet-18, ResNet-50, ResNet-101, ShuffleNet, SqueezeNet, VGG-16, VGG-19, and Xception. Their performances were evaluated quantitatively using six assessment metrics: specificity, sensitivity, precision, negative predictive value (NPV), accuracy, and F1-score. The top four models with accuracy higher than 90% are VGG-16, ResNet-101, VGG-19, and SqueezeNet. The accuracy of these top four models is between 90.7% and 94.3%; the F1-score is between 90.8% and 94.3%. The VGG-16 scored the highest accuracy of 94.3% and F1-score of 94.3%. The majority voting with all the 18 CNN models and top 4 models produced an accuracy of 93.0% and 94.0%, respectively. The top four and bottom three models were chosen for the qualitative analysis. A gradient-weighted class activation mapping (Grad-CAM) was used to visualize the significant region of activation for the decision-making of image classification. Two certified radiologists performed blinded subjective voting on the Grad-CAM images in comparison with their diagnosis. The qualitative analysis showed that SqueezeNet is the closest model to the diagnosis of two certified radiologists. It demonstrated a competitively good accuracy of 90.7% and F1-score of 90.8% with 111 times fewer parameters and 7.7 times faster than VGG-16. Therefore, this study recommends both VGG-16 and SqueezeNet as additional tools for the diagnosis of COVID-19.
  5. Feng Y, Chow LS, Gowdh NM, Ramli N, Tan LK, Abdullah S
    PMID: 39142299 DOI: 10.1088/2057-1976/ad6f17
    Neuromyelitis optica spectrum disorder (NMOSD), also known as Devic disease, is an autoimmune central nervous system disorder in humans that commonly causes inflammatory demyelination in the optic nerves and spinal cord. Inflammation in the optic nerves is termed optic neuritis (ON). ON is a common clinical presentation; however, it is not necessarily present in all NMOSD patients. ON in NMOSD can be relapsing and result in severe vision loss. To the best of our knowledge, no study utilises deep learning to classify ON changes on MRI among patients with NMOSD. Therefore, this study aims to deploy eight state-of-the-art CNN models (Inception-v3, Inception-ResNet-v2, ResNet-101, Xception, ShuffleNet, DenseNet-201, MobileNet-v2, and EfficientNet-B0) with transfer learning to classify NMOSD patients with and without chronic ON using optic nerve magnetic resonance imaging. This study also investigated the effects of data augmentation before and after dataset splitting on cropped and whole images. Both quantitative and qualitative assessments (with Grad-Cam) were used to evaluate the performances of the CNN models. The Inception-v3 was identified as the best CNN model for classifying ON among NMOSD patients, with accuracy of 99.5%, sensitivity of 98.9%, specificity of 93.0%, precision of 100%, NPV of 99.0%, and F1-score of 99.4%. This study also demonstrated that the application of augmentation after dataset splitting could avoid information leaking into the testing datasets, hence producing more realistic and reliable results.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links