Displaying all 5 publications

Abstract:
Sort:
  1. Abubakar A, Zin HM
    Biomed Phys Eng Express, 2020 Nov 09;6(6).
    PMID: 35102003 DOI: 10.1088/2057-1976/abc635
    The purpose of this study is to develop a method for characterisation of time-of-flight (ToF) imaging system for application in deep inspiration breath-hold radiotherapy (DIBH-RT). The performance of an Argos 3D P330 ToF camera (Bluetechnix, Austria) was studied for patient surface monitoring during DIBH-RT using a phantom to simulate the intra-patient and inter-patient stability of the camera. Patient setup error was also simulated by positioning the phantom at predefined shift positions (2, 5 and 10 mm) from the isocentre. The localisation accuracy of the phantom was measured using ToF imaging system and repeated using CBCT imaging alone (CBCT) and simultaneously using ToF imaging during CBCT imaging (ToF-CBCT). The mean and SD of the setup errors obtained from each of the imaging methods were calculated. Student t-test was used to compare the mean setup errors. Correlation and Bland-Altman analysis were also performed. The intra-and inter-patient stability of the camera were within 0.31 mm and 0.74 mm, respectively. The localisation accuracy in terms of the mean ±SD of the measured setup errors were 0.34 ± 0.98 mm, 0.12 ± 0.34 mm, and -0.24 ± 1.42 mm for ToF, CBCT and ToF-CBCT imaging, respectively. A strong correlation was seen between the phantom position and the measured position using ToF (r = 0.96), CBCT (r = 0.99) as well as ToF-CBCT (r = 0.92) imaging. The limits of agreement from Bland Altman analysis between the phantom position and ToF, CBCT and ToF-CBCT measured positions were -1.52, 2.31 mm, -0.55, 0.78 mm; and -3.03, 2.55 mm, respectively. The sensor shows good stability and high accuracy comparable to similar sensors in the market. The method developed is useful for characterisation of an optical surface imaging system for application in monitoring DIBH-RT.
  2. Lam SE, Noor NM, Bradley DA, Mahmud R, Pawanchek M, Abdul Rashid HA
    Biomed Phys Eng Express, 2020 Nov 05;6(6).
    PMID: 35042836 DOI: 10.1088/2057-1976/abc2a4
    This work investigates the suitability of locally fabricated 6 mol% Ge-doped optical fibres as dosimeters for small-field output ratio measurements. Two fabrications of fibre, cylindrical (CF) and flat (FF) fibres, were used to measure doses in small photon fields, from 4 to 15 mm. The findings were compared to those of commercial Ge-doped fibre (COMM), EBT3 film and an IBA CC01 ionization chamber. Irradiations were carried out using a 6 MV SRS photon beam operating at a dose rate of 1000 cGy min-1, delivering a dose of 16 Gy. To minimise the possibility of the fibres failing to be exposed to the intended dose in small fields, the fibres were accommodated in a custom-made Perspex phantom. For the 4 mm cone the CF and FF measured output ratios were found to be smaller than obtained with EBT3 film by 32% and 13% respectively. Conversely, while for the 6 to 15 mm cone fields the FF output ratios were consistently greater than those obtained using EBT3 film, the CF output ratios differed from those of EBT3 film by at most 3.2%, at 6 mm, otherwise essentially agreeing with EBT3 values at the other field sizes. For the 4 to 7.5 mm cones, all output ratios obtained from Ge-doped optical fibre measurements were greater than those of IBA CC01 ionization chamber. The measured FF and CF output ratios for the 7.5 to 15 mm cones agreed with published MC estimates to within 15% and 13%, respectively. Down to 6 mm cone field, present measurements point to the potential of CF as a small-field dosimeter, its use recommended to be complemented by the use of EBT3 film for small-field dosimetry.
  3. Anam C, Naufal A, Sutanto H, Arifin Z, Hidayanto E, Tan LK, et al.
    Biomed Phys Eng Express, 2023 May 30;9(4).
    PMID: 37216929 DOI: 10.1088/2057-1976/acd785
    Objective. To develop an algorithm to measure slice thickness running on three types of Catphan phantoms with the ability to adapt to any misalignment and rotation of the phantoms.Method. Images of Catphan 500, 504, and 604 phantoms were examined. In addition, images with various slice thicknesses ranging from 1.5 to 10.0 mm, distance to the iso-center and phantom rotations were also examined. The automatic slice thickness algorithm was carried out by processing only objects within a circle having a diameter of half the diameter of the phantom. A segmentation was performed within an inner circle with dynamic thresholds to produce binary images with wire and bead objects within it. Region properties were used to distinguish wire ramps and bead objects. At each identified wire ramp, the angle was detected using the Hough transform. Profile lines were then placed on each ramp based on the centroid coordinates and detected angles, and the full-width at half maximum (FWHM) was determined for the average profile. The slice thickness was obtained by multiplying the FWHM by the tangent of the ramp angle (23°).Results. Automatic measurements work well and have only a small difference (<0.5 mm) from manual measurements. For slice thickness variation, automatic measurement successfully performs segmentation and correctly locates the profile line on all wire ramps. The results show measured slice thicknesses that are close (<3 mm) to the nominal thickness at thin slices, but slightly deviated for thicker slices. There is a strong correlation (R2= 0.873) between automatic and manual measurements. Testing the algorithm at various distances from the iso-center and phantom rotation angle also produced accurate results.Conclusion. An automated algorithm for measuring slice thickness on three types of Catphan CT phantom images has been developed. The algorithm works well on various thicknesses, distances from the iso-center, and phantom rotations.
  4. Moradi F, Jalili M, Saraee KRE, Abdi MR, Rashid HAA
    Biomed Phys Eng Express, 2024 Feb 14;10(2).
    PMID: 38320327 DOI: 10.1088/2057-1976/ad26d5
    The inherent biological hazards associated with ionizing radiation necessitate the implementation of effective shielding measures, particularly in medical applications. Interventional radiology, in particular, poses a unique challenge as it often exposes medical personnel to prolonged periods of high x-ray doses. Historically, lead and lead-based compounds have been the primary materials employed for shielding against photons. However, the drawbacks of lead, including its substantial weight causing personnel's inflexibility and its toxicity, have raised concerns regarding its long-term impact on both human health and the environment. Barium tantalate has emerged as a promising alternative, due to its unique attenuation properties against low-energy x-rays, specifically targeting the weak absorption area of lead. In the present study, we employ the Geant4 Monte Carlo simulation tool to investigate various formulations of barium tantalate doped with rare earth elements. The aim is to identify the optimal composition for shielding x-rays in the context of interventional radiology. To achieve this, we employ a reference x-ray spectrum typical of interventional radiology procedures, with energies extending up to 90 keV, within a carefully designed simulation setup. Our primary performance indicator is the reduction in air kerma transmission. Furthermore, we assess the absorbed doses to critical organs at risk within a standard human body phantom protected by the shield. Our results demonstrate that specific concentrations of the examined rare earth impurities can enhance the shielding performance of barium tantalate. To mitigate x-ray exposure in interventional radiology, our analysis reveals that the most effective shielding performance is achieved when using barium tantalate compositions containing 15% Erbium or 10% Samarium by weight. These findings suggest the possibility of developing lead-free shielding solutions or apron for interventional radiology personnel, offering a remarkable reduction in weight (exceeding 30%) while maintaining shielding performance at levels comparable to traditional lead-based materials.
  5. Ali M, Mohd Noor SNF, Mohamad H, Ullah F, Javed F, Abdul Hamid ZA
    Biomed Phys Eng Express, 2024 Apr 17;10(3).
    PMID: 38224615 DOI: 10.1088/2057-1976/ad1e75
    Guided tissue/bone regeneration (GTR/GBR) is a widely used technique in dentistry to facilitate the regeneration of damaged bone and tissue, which involves guiding materials that eventually degrade, allowing newly created tissue to take its place. This comprehensive review the evolution of biomaterials for guided bone regeneration that showcases a progressive shift from non-resorbable to highly biocompatible and bioactive materials, allowing for more effective and predictable bone regeneration. The evolution of biomaterials for guided bone regeneration GTR/GBR has marked a significant progression in regenerative dentistry and maxillofacial surgery. Biomaterials used in GBR have evolved over time to enhance biocompatibility, bioactivity, and efficacy in promoting bone growth and integration. This review also probes into several promising fabrication techniques like electrospinning and latest 3D printing fabrication techniques, which have shown potential in enhancing tissue and bone regeneration processes. Further, the challenges and future direction of GTR/GBR are explored and discussed.