Displaying all 3 publications

Abstract:
Sort:
  1. Baxter R, Patriarca PA, Ensor K, Izikson R, Goldenthal KL, Cox MM
    Vaccine, 2011 Mar 9;29(12):2272-8.
    PMID: 21277410 DOI: 10.1016/j.vaccine.2011.01.039
    Alternative methods for influenza vaccine production are needed to ensure adequate supplies.
  2. Prodan Z, Mroczek T, Sivalingam S, Bennink G, Asch FM, Cox M, et al.
    PMID: 33984478 DOI: 10.1053/j.semtcvs.2021.03.036
    Valved allografts and xenografts for reconstruction of the right ventricular outflow tract (RVOT) lack durability and do not grow. We report the first clinical use of a completely bioabsorbable valved conduit (Xeltis pulmonary valve - XPV) in children. Twelve children (six male), median age five (two to twelve) years and median weight 17 (10 to 43) kg, underwent RVOT reconstruction with the XPV. Diagnoses were: pulmonary atresia with ventricular septal defect (VSD) (n=4), tetralogy of Fallot (n=4), common arterial trunk (n=3), and transposition of the great arteries with VSD and pulmonary stenosis (n=1). All had had previous surgery, including prior RVOT conduit implantation in six. Two diameters of conduit 16mm (n=5) and 18mm (n=7) were used. At 24 months none of the patients has required surgical re-intervention, 9 of the 12 are in NYHA functional class I and three patients in NYHA class II. None of the conduits has shown evidence of progressive stenosis, dilation or aneurysm formation. Residual peak gradient of >40 mm Hg was observed in three patients, caused by kinking of the conduit at implantation in 1 and distal stenosis in the peripheral pulmonary arteries in 2 patients. Five patients developed severe pulmonary valve insufficiency (PI); the most common mechanism was prolapse of at least one of the valve leaflets. The XPV conduit is a promising innovation for RVOT reconstruction. Progressive PI requires however an improved design (geometry, thickness) of the valve leaflets.
  3. Morales DL, Herrington C, Bacha EA, Morell VO, Prodán Z, Mroczek T, et al.
    Front Cardiovasc Med, 2020;7:583360.
    PMID: 33748192 DOI: 10.3389/fcvm.2020.583360
    Objectives: We report the first use of a biorestorative valved conduit (Xeltis pulmonary valve-XPV) in children. Based on early follow-up data the valve design was modified; we report on the comparative performance of the two designs at 12 months post-implantation. Methods: Twelve children (six male) median age 5 (2 to 12) years and weight 17 (10 to 43) kg, had implantation of the first XPV valve design (XPV-1, group 1; 16 mm (n = 5), and 18 mm (n = 7). All had had previous surgery. Based on XPV performance at 12 months, the leaflet design was modified and an additional six children (five male) with complex malformations, median age 5 (3 to 9) years, and weight 21 (14 to 29) kg underwent implantation of the new XPV (XPV-2, group 2; 18 mm in all). For both subgroups, the 12 month clinical and echocardiographic outcomes were compared. Results: All patients in both groups have completed 12 months of follow-up. All are in NYHA functional class I. Seventeen of the 18 conduits have shown no evidence of progressive stenosis, dilation or aneurysm formation. Residual gradients of >40 mm Hg were observed in three patients in group 1 due to kinking of the conduit (n = 1), and peripheral stenosis of the branch pulmonary arteries (n = 2). In group 2, one patient developed rapidly progressive stenosis of the proximal conduit anastomosis, requiring conduit replacement. Five patients in group 1 developed severe pulmonary valve regurgitation (PI) due to prolapse of valve leaflet. In contrast, only one patient in group 2 developed more than mild PI at 12 months, which was not related to leaflet prolapse. Conclusions: The XPV, a biorestorative valved conduit, demonstrated promising early clinical outcomes in humans with 17 of 18 patients being free of reintervention at 1 year. Early onset PI seen in the XPV-1 version seems to have been corrected in the XPV-2, which has led to the approval of an FDA clinical trial. Clinical Trial Registration: www.ClinicalTrials.gov, identifier: NCT02700100 and NCT03022708.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links