Displaying all 3 publications

Abstract:
Sort:
  1. Al-Fakih EA, Abu Osman NA, Mahmad Adikan FR
    Sensors (Basel), 2016 Jul 20;16(7).
    PMID: 27447646 DOI: 10.3390/s16071119
    The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During the past 50 years a variety of measurement techniques have been employed in an effort to identify sites of excessive stresses which may lead to skin breakdown, compare stress distributions in various socket designs, and evaluate interface cushioning and suspension systems, among others. The outcomes of such measurement techniques have contributed to improving the design and fitting of transtibial sockets. This article aims to review the operating principles, advantages, and disadvantages of conventional and emerging techniques used for interface stress measurements inside transtibial sockets. It also reviews and discusses the evolution of different socket concepts and interface stress investigations conducted in the past five decades, providing valuable insights into the latest trends in socket designs and the crucial considerations for effective stress measurement tools that lead to a functional prosthetic socket.
  2. Al-Fakih EA, Osman NA, Eshraghi A, Adikan FR
    Sensors (Basel), 2013 Aug 12;13(8):10348-57.
    PMID: 23941909 DOI: 10.3390/s130810348
    This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ~0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction.
  3. AlManie SA, AlHazami MS, Ebrahim A, Attique MS
    Clinicoecon Outcomes Res, 2024;16:509-522.
    PMID: 39069972 DOI: 10.2147/CEOR.S467543
    OBJECTIVE: This study aims to estimate the direct medical cost of COVID-19 hospitalizations and to utilize prevalence estimates from Jaber Al-Ahmad Hospital to estimate the direct medical cost of all hospitalized adult patients in Kuwait using a decision tree analysis.

    METHODS: A cost-of-illness model was developed. The Ministry of Health perspective was considered, direct medical costs were estimated from July 1st to September 30th, using a bottom-up approach. The mean cost per hospitalized patient was estimated using a decision analysis model. Prevalence estimates of ambulance use, use of ER, ICU admission, and mortality were considered in the current study. Patients aged 18 years and above with a confirmed diagnosis of COVID-19 were included. One-way sensitivity analysis and probabilistic sensitivity analysis (PSA) were performed.

    RESULTS: Data for 2986 patients were analyzed. The mean age was 61 (SD= 11) years old. Most of the patients were Kuwaiti (2864, 95.91%), and more than half were females (1677, 56.16%). Of the total hospital admissions, 417 patients (14%) were admitted to the ICU. The average length of the hospital stay was 11 (SD= 9) days, and among all hospital admissions, 270 (9.04%) patients died. The total estimated direct medical cost of hospitalized patients at Jaber Al-Ahmad Hospital was $47,213,768 (14,283,203.6 KD). The average cost of hospital stay per patient was estimated at $15,498 (4,688.60 KD). The weighted average cost per hospitalized patient in Kuwait was estimated at $16,373 (4,953.08 KD). The total direct medical cost of hospitalized COVID-19 patients in Kuwait during the study period was estimated at $174,372,450 (52,751,502 KD).

    CONCLUSION: The COVID-19 pandemic constituted a significant burden on the Kuwaiti healthcare system. The findings of this study urge the need for preventive care strategies to reduce adverse health outcomes and the economic impact of the pandemic.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links