Displaying all 3 publications

Abstract:
Sort:
  1. Kamsani SH, Emami M, Young GD, Dimasi C, Pathak RK, Wilsmore B, et al.
    Heart Rhythm, 2024 Nov 07.
    PMID: 39515499 DOI: 10.1016/j.hrthm.2024.10.070
    BACKGROUND: Different iterations of catheter and energy delivery system configurations are evolving for pulsed field ablation (PFA); however, some have used large and complex catheters, required large sheaths, and had a recognized risk of hemolysis.

    OBJECTIVE: The purpose of this study was to evaluate the acute safety and efficacy of a custom designed 8F variable loop multielectrode mapping and PFA catheter with contact sensing.

    METHODS: This acute feasibility study recruited 30 patients undergoing de novo ablation of paroxysmal or persistent atrial fibrillation (AF). The ElectroPulse Study is a first-in-human, nonrandomized, prospective study of a novel PFA system that utilizes an 8F, 10-electrode variable loop steerable mapping and ablation catheter with 2800-V biphasic bipolar waveform. All patients had pulmonary vein isolation (PVI) and posterior wall isolation (PWI) using the PFA system. The main outcomes were the acute success of PV/PWI and periprocedural serious adverse events.

    RESULTS: Complete PVI/PWI was successfully achieved in all 30 patients using 59.7 ± 7.2 applications. Total procedural time was 113.6 ± 26.3 minutes, fluoroscopy time 8.0 ± 5.5 minutes, and left atrial dwell time 78.7 ± 18.6 minutes. There was no esophageal injury, phrenic nerve palsy, clinical stroke, or death. Brain magnetic resonance imaging detected 2 new but transient silent cerebral lesions. Two patients (6.7%) had vascular access complications. Although there were changes in the biomarkers for hemolysis, none of the patients experienced clinical hemolysis or related acute kidney injury.

    CONCLUSION: This first-in-human study demonstrated that PFA using a novel variable loop catheter with a contact sensing system safely achieved 100% acute PVI/PWI with safety profile comparable to existing PFA systems.

  2. Kamsani SH, Middeldorp ME, Chiang G, Stefil M, Evans S, Nguyen MT, et al.
    Heart Rhythm O2, 2024 Jun;5(6):341-350.
    PMID: 38984365 DOI: 10.1016/j.hroo.2024.05.003
    BACKGROUND: Inpatient monitoring is recommended for sotalol initiation.

    OBJECTIVE: The purpose of this study was to assess the safety of outpatient sotalol commencement.

    METHODS: This is a multicenter, retrospective, observational study of patients initiated on sotalol in an outpatient setting. Serial electrocardiogram monitoring at day 3, day 7, 1 month, and subsequently as clinically indicated was performed. Corrected QT (QTc) interval and clinical events were evaluated.

    RESULTS: Between 2008 and 2023, 880 consecutive patients who were commenced on sotalol were evaluated. Indications were atrial fibrillation/flutter in 87.3% (n = 768), ventricular arrhythmias in 9.9% (n = 87), and other arrhythmias in 2.8% (n = 25). The daily dosage at initiation was 131.0 ± 53.2 mg/d. The QTc interval increased from baseline (431 ± 32 ms) to 444 ± 37 ms (day 3) and 440 ± 33 ms (day 7) after sotalol initiation (P < .001). Within the first week, QTc prolongation led to the discontinuation of sotalol in 4 and dose reduction in 1. No ventricular arrhythmia, syncope, or death was observed during the first week. Dose reduction due to asymptomatic bradycardia occurred in 3 and discontinuation due to dyspnea in 3 within the first week. Overall, 1.1% developed QTc prolongation (>500 ms/>25% from baseline); 4 within 3 days, 1 within 1 week, 4 within 60 days, and 1 after >3 years. Discontinuation of sotalol due to other adverse effects occurred in 41 patients within the first month of therapy.

    CONCLUSION: Sotalol initiation in an outpatient setting with protocolized follow-up is safe, with no recorded sotalol-related mortality, ventricular arrhythmias, or syncope. There was a low incidence of significant QTc prolongation necessitating discontinuation within the first month of treatment. Importantly, we observed a small incidence of late QT prolongation, highlighting the need for vigilant outpatient surveillance of individuals on sotalol.

  3. Kamsani SH, Fitzgerald JL, Thiyagarajah A, Evans S, Jayakumar M, Ariyaratnam JP, et al.
    Heart Rhythm O2, 2025 Mar;6(3):253-258.
    PMID: 40201670 DOI: 10.1016/j.hroo.2024.12.009
    BACKGROUND: Left bundle branch area pacing (LBBAP) has recently emerged as a strategy for conduction system pacing.

    OBJECTIVE: The purpose of this study was to evaluate the initial learning experience and acute procedural success in adopting this procedure in an academic training center.

    METHODS: A retrospective review of LBBAP procedures using the Biotronik Solia stylet-driven lead from June 2022 to December 2023 was performed. Procedural and fluoroscopy times with electrocardiographic and pacing parameters were evaluated to determine safety and acute procedural outcomes.

    RESULTS: A total of 69 patients (mean age 75 ± 12 years; 60.9% male) underwent LBBAP implantation over 18 months for standard pacing indications by 10 implanters (including 7 fellows-in-training) without previous experience in LBBAP technique. Mean total procedural time was 74.1 ± 23.5 minutes, and mean fluoroscopy time for LBBAP lead insertion was 9.3 ± 5.4 minutes. Mean paced QRS duration was 115.2 ± 15.5 ms, and mean left ventricular activation time was 79.4 ± 14.5 ms. An rsR' pattern was achieved in 76.8%. LBBAP was successful in 78.3% (overall 43.5% single deployment; median 2 [interquartile range 1-3]) with excellent LBBAP lead parameters: threshold 0.8 ± 0.4 V at 0.4 ms; sensing 9.4 ± 4.2 mV; impedance 627 ± 131 Ω. Acute procedural complications included damaged lead helix requiring a second lead (4.3%), pneumothorax (2.9%), and acute LBBAP lead dislodgment (1.4%). Septal perforation occurred in 10.1% of cases with no acute sequelae. When analyzed in tertiles, the number of lead deployment attempts was significantly reduced with no changes to procedural success rates with increasing experience.

    CONCLUSION: Adoption of LBBAP with stylet-driven lead in an academic training center is feasible and safe, with satisfactory success rates and no overly steep learning curve.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links