Displaying all 3 publications

Abstract:
Sort:
  1. Shiek Ahmad B, Wark JD, Petty SJ, O'Brien TJ, Gorelik A, Sambrook PN, et al.
    Epilepsia, 2015 Nov;56(11):1714-22.
    PMID: 26513212 DOI: 10.1111/epi.13136
    To investigate cross-sectional and longitudinal differences in static and dynamic standing balance measures and lower limb muscle strength in patients who are treated chronically with antiepileptic drugs (AEDs).
  2. Shiek Ahmad B, O'Brien TJ, Gorelik A, Hill KD, Wark JD
    J Clin Densitom, 2016 Oct;19(4):450-456.
    PMID: 27553750 DOI: 10.1016/j.jocd.2016.07.008
    Antiepileptic drug (AED) therapy is associated with decreased bone mineral density; however, the time course for this development is unclear. The aim of this study was to evaluate bone mineral changes during the initial years of AED therapy in AED-naive, newly diagnosed epilepsy patients compared with non-AED users. In 49 epilepsy patients newly started on AEDs and in 53 non-AED users of both genders, bone mineral density (BMD) and bone mineral content were measured using dual-energy X-ray absorptiometry at baseline (within the first year of therapy) and at least 1 yr later. Bone changes between the 2 assessments, adjusted for age, height, and weight, were calculated as the annual rate of change. The median duration of AED therapy was 3.5 mo at baseline and 27.6 mo at follow-up. No overall difference was found in mean BMD and bone mineral content measures between user and nonuser cohorts in both cross-sectional baseline and the annual rate of change (p > 0.05). However, users on carbamazepine monotherapy (n = 11) had an increased annual rate of total hip (-2.1% vs -0.8%, p = 0.020) and femoral neck BMD loss (-2.1% vs -0.6%, p = 0.032) compared to nonusers. They also had a marginally higher rate of femoral neck BMD loss (-2.1%, p = 0.049) compared with valproate (-0.1%, n = 13) and levetiracetam users (+0.6%, n = 13). During the initial years of AED treatment for epilepsy, no difference was found in bone measures between AED users as a group and nonuser cohorts. However, the data suggested that carbamazepine monotherapy was associated with increased bone loss at the hip regions, compared to users of levetiracetam or valproate and nonusers. Larger studies of longer duration are warranted to better delineate the bone effects of specific AEDs, with further consideration of the role of early dual-energy X-ray absorptiometry scanning and careful AED selection in potentially minimizing the impact on bone health in these patients.
  3. Shiek Ahmad B, Petty SJ, Gorelik A, O'Brien TJ, Hill KD, Christie JJ, et al.
    Osteoporos Int, 2017 Sep;28(9):2591-2600.
    PMID: 28589417 DOI: 10.1007/s00198-017-4098-9
    Changes in areal bone mineral density (aBMD) and other predictors of bone loss were evaluated in 48 same-sex twin/age-matched sibling pairs discordant for antiepileptic drug (AED) use. AED users had reduced BMD at the hip regions. Prolonged AED users had greater aBMD loss, predicting a higher risk of bone fragility.

    INTRODUCTION: To investigate the longitudinal associations of bone mineral measures with antiepileptic drug (AED) use, including enzyme-inducing (EIAED) and non-enzyme-inducing (NEIAED) types, and other predictors of bone loss in a study of 48 same-sex twin/age-matched sibling pairs (40 female, 8 male) discordant for AED use.

    METHODS: Using dual-energy X-ray absorptiometry (DXA), areal bone mineral density (aBMD) and content (BMC) at the hip regions, forearm, lumbar spine, and whole body were measured twice, at least 2 years apart. The mean within-pair difference (MWPD), MWPD%, and mean annual rate of aBMD change were adjusted for age, weight, and height. Predictors of bone loss were evaluated.

    RESULTS: AED users, compared to non-users, at baseline and follow-up, respectively, had reduced aBMD at the total hip (MWPD% 3.8, 4.4%), femoral neck (4.7, 4.5%), and trochanter regions (4.1, 4.6%) (p  0.05) regions did not differ within pairs. Nevertheless, EIAED users had greater aBMD loss than non-users (n = 20 pairs) at the total hip (1.7 vs. 0.3%, p = 0.013) and whole body regions (0.7% loss vs. 0.1% BMD gain, p = 0.019), which was not found in NEIAED-discordant pairs (n = 16). AED use >20 years predicted higher aBMD loss at the forearm (p = 0.028), whole body (p = 0.010), and whole body BMC (p = 0.031).

    CONCLUSIONS: AED users had reduced aBMD at the hip regions. Prolonged users and EIAED users had greater aBMD loss, predicting a higher risk of bone fragility. Further prospective studies of AED effects on bone microarchitecture are needed.

Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links