Displaying all 2 publications

Abstract:
Sort:
  1. Hambali AS, Ng KH, Abdullah BJ, Wang HB, Jamal N, Spelic DC, et al.
    Radiat Prot Dosimetry, 2009 Jan;133(1):25-34.
    PMID: 19223292 DOI: 10.1093/rpd/ncp007
    This study was undertaken to compare the entrance surface dose (ESD) and image quality of adult chest and abdominal X-ray examinations conducted at general practitioner (GP) clinics, and public and private hospitals in Malaysia. The surveyed facilities were randomly selected within a given category (28 GP clinics, 20 public hospitals and 15 private hospitals). Only departmental X-ray units were involved in the survey. Chest examinations were done at all facilities, while only hospitals performed abdominal examinations. This study used the x-ray attenuation phantoms and protocols developed for the Nationwide Evaluation of X-ray Trends (NEXT) survey program in the United States. The ESD was calculated from measurements of exposure and clinical geometry. An image quality test tool was used to evaluate the low-contrast detectability and high-contrast detail performance under typical clinical conditions. The median ESD value for the adult chest X-ray examination was the highest (0.25 mGy) at GP clinics, followed by private hospitals (0.22 mGy) and public hospitals (0.17 mGy). The median ESD for the adult abdominal X-ray examination at public hospitals (3.35 mGy) was higher than that for private hospitals (2.81 mGy). Results of image quality assessment for the chest X-ray examination show that all facility types have a similar median spatial resolution and low-contrast detectability. For the abdominal X-ray examination, public hospitals have a similar median spatial resolution but larger low-contrast detectability compared with private hospitals. The results of this survey clearly show that there is room for further improvement in performing chest and abdominal X-ray examinations in Malaysia.
  2. Ng KH, Rassiah P, Wang HB, Hambali AS, Muthuvellu P, Lee HP
    Br J Radiol, 1998 Jun;71(846):654-60.
    PMID: 9849390
    A collaborative national survey initiated by the University of Malaya and the Ministry of Health was conducted from 1993 to 1995 to establish baseline patient dose data for seven common types (12 projections) of X-ray examinations in Malaysia. A total of 12 randomly selected public hospitals and 867 patients were included in this survey. The entrance surface doses (ESD) received by the patients were measured using thermoluminescent dosemeters (TLDs) attached to the patient's skin. Histograms are presented showing wide, positively skewed distributions of measured entrance surface doses for each examination. Mean, median, first and third quartile values of ESD and median effective dose are reported. Survey results are generally comparable with those reported in the UK, USA and by the International Atomic Energy Agency (IAEA). The results also provide information on dose level for a lower weight population (mean weight 60 kg) compared with the international reference dose values based on a 70 kg standard. The findings support the importance of the on-going national quality assurance programme to ensure doses are kept to a level consistent with optimum image quality. The data will also be useful for the formulation of national guidance levels as recommended by the IAEA. Furthermore, this study provides patient dosimetry information on healthcare level II countries.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links