METHODS: (a) Five dummy bones were packed with DI, GI, or IP in a polystyrene box. The bone temperatures were monitored while the boxes were placed at room temperature over 96 h. Durations for each cooling material maintaining freezing temperatures below -40°C, -20°C, and 0°C were obtained from the bone temperature over time profiles. (b) Composites of DI (20, 15, 10, 5, and 0 kg) and GI were used to pack five dummy bones in a polystyrene box. The durations maintaining varying levels of freezing temperature were compared.
RESULTS: DI (20 kg) maintained temperature below -40°C for 76.4 h as compared to 6.3 h in GI (20 bags) and 4.0 h in IP (15 packs). Composites of 15DI (15 kg DI and 9 GI bags) and 10DI (10 kg DI and 17 GI bags) maintained the temperature below -40°C for 61 and 35.5 h, respectively.
CONCLUSION: Composites of DI and GI can be used to maintain bones in deep frozen state during irradiation, thus avoiding radiation effects on biomechanical properties. Sterile frozen bone allograft with preserved functional properties is required in clinical applications.