Displaying all 6 publications

Abstract:
Sort:
  1. Awang N, Jamaluddin F
    J Environ Public Health, 2014;2014:408275.
    PMID: 25136371 DOI: 10.1155/2014/408275
    This study was carried out to determine the concentration of lead (Pb), anions, and cations at six primary schools located around Kuala Lumpur. Low volume sampler (MiniVol PM10) was used to collect the suspended particulates in indoor and outdoor air. Results showed that the concentration of Pb in indoor air was in the range of 5.18 ± 1.08 μg/g-7.01 ± 0.08 μg/g. All the concentrations of Pb in indoor air were higher than in outdoor air at all sampling stations. The concentrations of cations and anions were higher in outdoor air than in indoor air. The concentration of Ca(2+) (39.51 ± 5.01 mg/g-65.13 ± 9.42 mg/g) was the highest because the cation existed naturally in soil dusts, while the concentrations of NO3 (-) and SO4 (2-) were higher in outdoor air because there were more sources of exposure for anions in outdoor air, such as highly congested traffic and motor vehicles emissions. In comparison, the concentration of NO3 (-) (29.72 ± 0.31 μg/g-32.00 ± 0.75 μg/g) was slightly higher than SO4 (2-). The concentrations of most of the parameters in this study, such as Mg(2+), Ca(2+), NO3 (-), SO4 (2-), and Pb(2+), were higher in outdoor air than in indoor air at all sampling stations.
  2. Mohd Ariffin ZA, Jamaluddin FA
    Malays J Pathol, 2020 Dec;42(3):395-400.
    PMID: 33361720
    INTRODUCTION: One commonly used equation which continues to be widely mentioned in text books and hence familiar to clinical people is total calcium + 0.02 (40 - albumin). This equation was derived using cresophthalein complexone and bromocresol green (BCG) methods for measuring serum total calcium and serum albumin respectively. However this equation maybe invalid when applied to calcium and albumin results generated by alternative assays. Hence we aim to derive an albumin-adjusted calcium equation specific to our laboratory's total calcium and albumin methodologies.

    MATERIALS AND METHODS: A total of 3,175 adult University Malaya Medical Centre (UMMC) patients deemed free of any calcium metabolism disorders were selected and divided into two groups for derivation and validation. Simple linear regression associating total calcium and albumin was constructed from the data in the derivation group. The new albumin-adjusted calcium equation was validated in the validation group. Differences in calcium status classification following adjustments based on existing and new albumin-adjusted calcium equation was compared in a 469 hypoalbuminaemic patients.

    RESULT: The new albumin adjusted calcium equation was: total calcium + 0.014 x (39-albumin). Of the 469 hypoalbuminemic patients, 78 were classified differently based on new equation. Based on the new equation, 55 normocalcemic patients were classified as hypocalcemic and 22 were classified as normocalcemic instead of hyperclacaemic.

    CONCLUSION: Based on the newly derived albuminadjusted calcium equation 17% of patients had different adjusted calcium classifications. This could potentially impact in the management. It is recommended that laboratories derive equations specific to their calcium/albumin methods and analytical platforms.

  3. Jamaluddin FA, Sthaneshwar P, Hussein Z, Othman N, Chan SP
    Malays J Pathol, 2013 Jun;35(1):59-63.
    PMID: 23817395 MyJurnal
    Prolactin (PRL) exists in different forms in human serum. The predominant form is monomeric PRL (molecular mass 23 kDa) with smaller amounts of big PRL (molecular mass 50-60 kDa) and at times macroprolactin (molecular mass 150-170 kDa). Macroprolactin, generally considered to be biologically inactive, accounts for the major part of prolactin in some patients. Different immunoassays for prolactin differ in reactivity with this macromolecular complex.
  4. Zulkufli NS, Jamaluddin FA, Tengku Yazid TN
    Malays J Pathol, 2020 Dec;42(3):385-394.
    PMID: 33361719
    INTRODUCTION: Ionised calcium is a good prognostic and diagnostic tool as opposed to total calcium in critical patients but is not available in most central laboratories and non-intensive care units. To date, four equations to calculate ionised calcium in critical patients have been published.

    OBJECTIVES: (1) Evaluate the four published equations' performance in estimating ionised calcium; (2) Determine the accuracy of calculated ionised and adjusted total calcium in classifying patients according to calcium states; and (3) Identify factors associated with hypocalcaemia in the critically ill population.

    MATERIALS AND METHODS: This is a cross-sectional study involving 281 critically ill patients aged 18-80 years of both genders in a Malaysian tertiary intensive care unit. Performance of the four equations was analysed using Bland-Altman difference plot and Passing Bablok regression analysis. Crosstabulation was conducted to assess classification accuracy. Mann-Whitney U or Pearson Chi-Square tests were performed to identify variables associated with hypocalcaemia.

    RESULTS: Calculated ionised calcium using all four equations significantly overestimated ionised calcium. Calculated ionised and adjusted total calcium had poor accuracies in classifying hypocalcaemic patients. pH was significantly higher in hypocalcaemics.

    CONCLUSION: Calculated ionised and adjusted total calcium significantly overestimate ionised calcium in the critically ill. In this specific population, calcium status should only be confirmed with ionised calcium measured by direct ion-selective electrode (ISE).

  5. Fan SP, Zakaria S, Chia CH, Jamaluddin F, Nabihah S, Liew TK, et al.
    Bioresour Technol, 2011 Feb;102(3):3521-6.
    PMID: 21123058 DOI: 10.1016/j.biortech.2010.11.046
    Solvolysis of oil palm empty fruit bunches (EFB) fibres using different solvents (acetone, ethylene glycol (EG), ethanol, water and toluene) were carried out using an autoclave at 275°C for 60 min. The solvent efficiency in term of conversion yield was found to be: EG>water>ethanol>acetone>toluene. The liquid products and residue obtained were analyzed using Fourier transform infrared spectroscopy (FTIR) and gas chromatography/mass selectivity. The obtained results showed that the chemical properties of the oil product were significantly affected by the type of solvent used for the solvolysis process. The higher heating value (HHV) of oil products obtained using ethanol is ∼29.42 MJ/kg, which is the highest among the oil products produced using different solvents. Water, ethanol and toluene yield major phenolic compounds. While EG favors the formation of alcohol compounds and acetone yields ketone and aldehyde compounds.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links