BACKGROUND: BeGraft Aortic stent (Bentley InnoMed, Hechingen, Germany) allows large postdilation diameter up to 30 mm. With availability of lengths of 19-59 mm and lower stent profile, they can be used in native and recurrent CoA in adults and in pediatric patients.
MATERIALS AND METHODS: This is a multicentre retrospective analysis of 12 implanted BeGraft Aortic stents in CoA between May 2017 and April 2019.
RESULTS: Twelve patients aged 7.7-38 years (median 18.3 years) with body weight of 19.9-56 kg (median 45.5 kg). Eight patients (66%) had native juxtaductal CoA while four had recurrent CoA after previous surgical or transcatheter treatments. The stents were implanted successfully in all the patients with no serious adverse events. The length of the stents ranged from 27 to 59 mm and the implanted stent diameter varied from 12 to 18 mm. The median intraprocedural CoA pressure gradient decreased from 25 mmHg (range 16-66 mmHg) to 2 mmHg (range 0-13 mmHg). The mean follow-up duration was 10.2 months. Two patient (16.6%) had residual stent narrowing requiring staged redilation. One patient (8%) had pseudoaneurysm formation at 1 year cardiac CT follow-up.
CONCLUSIONS: The BeGraft Aortic stent may be considered to be safe and effective in the short term in treatment of CoA from childhood to adulthood. Long-term follow-up is needed.
MATERIALS AND METHODS: This was a multi-institutional, retrospective study involving all consecutive patients (>15 years old) with patent ductus arteriosus and severe pulmonary hypertension. Patients who had patent ductus arteriosus closure were divided into the Good (no death or hospital admissions due to worsening pulmonary hypertension) and the Poor Outcome groups and these groups were compared.
RESULTS: Thirty-seven patients [male: 9 (24.3%); mean age: 30.49 ± 9.56 years; median follow-up: 3 (IQR: 1.5,10) years] were included from four centers. Twenty-two patients who underwent patent ductus arteriosus closure, 15 (71.4%) had good outcomes while 7 (28.6%) had poor outcomes. Pulmonary vascular resistance index and pulmonary to systemic resistance ratio (Rp:Rs) were lower in the Good Outcome Group (14.35 ± 1.66 Wood units x m2 vs. 20.07 ± 2.44; p = 0.033 and 0.44 ± 0.16 vs. 1.08 ± 1.21; p = 0.042). Haemoglobin concentrations (<14.3 g/dL) were associated with good long-term outcomes in the Closed Group.
CONCLUSIONS: Patients with patent ductus arteriosus with severe pulmonary hypertension have a dismal outcome with or without closure. High haemoglobin levels at the time of occlusion predict a worse outcome for patients with patent ductus arteriosus and pulmonary hypertension.