Displaying all 2 publications

Abstract:
Sort:
  1. Krackhardt F, Kočka V, Waliszewski M, Toušek P, Janek B, Trenčan M, et al.
    Medicine (Baltimore), 2020 Feb;99(8):e19119.
    PMID: 32080086 DOI: 10.1097/MD.0000000000019119
    Stent designs with ultrathin struts may further increase the procedural success of challenging lesion subsets. The objective of this study was to assess the safety and efficacy of ultrathin strut, polymer-free sirolimus eluting stent (PF-SES) implantations in a large scale, unselected patient population.Adult patients underwent percutaneous coronary interventions (PCI) with a thin-strut PF-SES. Data from two all-comers observational studies having the same protocol (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were pooled. The accumulated target lesion revascularization (TLR) rate at 9-12 months was the primary endpoint. All dual antiplatelet therapy strategies according to the applicable guidelines were permissible.In total, 7243 patients were prospectively enrolled for PCI with PF-SES in stable coronary artery disease or acute coronary syndrome (ACS). Major risk factors in the overall cohort were diabetes (37.3%), ST elevation myocardial infarction (18.1%) and non-ST myocardial infarction (24.6%). The follow-up rate was 88.6% in the overall population. The TLR rate in the overall cohort was 2.2% whereas definite/probable stent thrombosis (ST) occurred in 0.7%. In patients with in-stent restenosis lesions, the major adverse cardiac events rate was 6.4% whereas the corresponding rate for isolated left main coronary artery (LMCA) disease was highest with 6.7% followed by patients with culprit lesions in vein bypasses (VB, 7.1%). The mortality rate in patients treated in VB lesions was highest with 5.4%, followed by the isolated LMCA subgroup (3.4%) and ACS (2.6%).PCI with PF-SES in an unselected patient population, is associated with low clinical event and ST rates. Furthermore, PF-SES angioplasty in niche indications demonstrated favorable safety and efficacy outcomes with high procedural success rates.
  2. Krackhardt F, Waliszewski M, Wan Ahmad WA, Kočka V, Toušek P, Janek B, et al.
    PLoS One, 2020;15(1):e0226606.
    PMID: 31929543 DOI: 10.1371/journal.pone.0226606
    BACKGROUND: The objective of this study was to assess regional and ethnic differences in an unselected patient population treated with polymer-free sirolimus-eluting stents (PF-SES) in Asia and Europe.

    METHODS: Two all-comers observational studies based on the same protocol (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were combined for data analysis to assure sufficient statistical power. The primary endpoint was the accumulated target lesion revascularization (TLR) rate at 9-12 months.

    RESULTS: Of the total population of 7243 patients, 44.0% (3186) were recruited in the Mediterranean region and 32.0% (2317) in central Europe. The most prominent Asian region was South Korea (17.6%, 1274) followed by Malaysia (5.7%, 413). Major cardiovascular risk factors varied significantly across regions. The overall rates for accumulated TLR and MACE were low with 2.2% (140/6374) and 4.4% (279/6374), respectively. In ACS patients, there were no differences in terms of MACE, TLR, MI and accumulated mortality between the investigated regions. Moreover, dual antiplatelet therapy (DAPT) regimens were substantially longer in Asian countries even in patients with stable coronary artery disease as compared to those in Europe.

    CONCLUSIONS: PF-SES angioplasty is associated with low clinical event rates in all regions. Further reductions in clinical event rates seem to be associated with longer DAPT regimens.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links