Displaying all 4 publications

Abstract:
Sort:
  1. Ahmad Z, Zafar Q, Sulaiman K, Akram R, Karimov KS
    Sensors (Basel), 2013;13(3):3615-24.
    PMID: 23493124 DOI: 10.3390/s130303615
    In this paper, we present the effect of varying humidity levels on the electrical parameters and the multi frequency response of the electrical parameters of an organic-inorganic composite (PEPC+NiPc+Cu2O)-based humidity sensor. Silver thin films (thickness ~200 nm) were primarily deposited on plasma cleaned glass substrates by the physical vapor deposition (PVD) technique. A pair of rectangular silver electrodes was formed by patterning silver film through standard optical lithography technique. An active layer of organic-inorganic composite for humidity sensing was later spun coated to cover the separation between the silver electrodes. The electrical characterization of the sensor was performed as a function of relative humidity levels and frequency of the AC input signal. The sensor showed reversible changes in its capacitance with variations in humidity level. The maximum sensitivity ~31.6 pF/%RH at 100 Hz in capacitive mode of operation has been attained. The aim of this study was to increase the sensitivity of the previously reported humidity sensors using PEPC and NiPc, which has been successfully achieved.
  2. Fatima N, Karimov KS, Qasuria TA, Ibrahim MA
    J Alloys Compd, 2020 Dec 30;849:156702.
    PMID: 32834521 DOI: 10.1016/j.jallcom.2020.156702
    In this research, due to the present pandemic of COVID-19, we are proposing a stable and fixed semitransparent photo-thermoelectric cell (PTEC) module for green energy harvesting. This module is based on the alloy of Bismuth Telluride Selenide (Bi2Te3Se), designed in a press tablet form and characterized under solar energy. Here, both aspects of solar energy i.e., light and heat are utilized for both energy production and water heating. The semitransparent PTEC converts heat energy directly to electrical energy due to the gradient of temperature between two electrodes (top and bottom) of thermoelectric cells. The PTEC is 25% transparent, which can be varied according to the necessity of the utilizer. The X-ray diffraction of material and electric characterization of module i.e., open-circuited voltage (VOC) and Seebeck coefficient were performed. The experimental observations disclose that in the proposed PTEC module with an increment in the average temperature (TAvg) from 34 to 60 °C, results in the rise of VOC ∼ 2.4 times. However, by modifying the size of heat-absorbing top electrode and by increasing the temperature gradient through the addition of water coolant under the bottom electrode, an uplift in the champion device results in as increment of VOC ∼5.5 times and Seebeck coefficient obtained was -250 μV/0C, respectively. Results show that not only the selection of material but also the external modifications in the device highly effective the power efficiency of the devices. The proposed modules can generate electric power from light and utilize the penetrating sunlight inside the room and for the heating of the water which also acts as a coolant. These semitransparent thermoelectric cells can be built-in within windows and roofs of buildings and can potentially contribute to green energy harvesting, in situations where movement is restricted locally or globally.
  3. Qasuria TA, Fatima N, Karimov KS, Ibrahim MA
    J Mater Res Technol, 2020;9(6):12795-12803.
    PMID: 38620721 DOI: 10.1016/j.jmrt.2020.09.025
    The present situation of COVID-19 diverted our focus towards utilizing the degraded solar cells for sensor application, this will help in global energy harvesting. So, here is our successful effort to reuse already degraded solar cells as ultraviolet (UV) and infrared (IR) sensor. The spin-coated perovskite (CH3NH3PbI3-XClX) has been already tested for visible light spectrum, as an extension to that now it is utilized as UV and IR intensity sensors to cover the whole spectrum. The employed CH3NH3PbI3-XClX material was used after its efficiency loss has been reached to a saturation point in photovoltaic devices. Each deposited layer was investigated from UV to the IR absorption spectrum for deepening study through UV-vis spectroscopy. In the sandwiched architecture possessing FTO/PEDOT: PSS/Perovskite/PC61BM/CdS/Au symmetry, the perovskite film has been employed as an absorbent layer, however, other layers participation also plays a key role. The resultant device yielded very good sensing performance because of the enhanced excitons generation which is attributed to the precise selection of the interfacial materials, e.g. CdS and PC61BM as an ETM and PEDOT: PSS as HTM. The impedance and capacitance of the devices within 0.01-200 kHz under varied UV and IR illumination intensities were investigated. Measurements showed that as the intensity of the light increased i.e., UV (0-200 W/m2) and IR (0-5800 W/m2), impedance decreased while capacitance increased. The current results are attributed to the increase in the concentration of charges i.e., electron-hole pairs generation depending on the built-in capacitance and frequency of the charges.
  4. Chani MTS, Karimov KS, Kamal T, Fatima N, Rahman MM, Asiri AM
    Polymers (Basel), 2023 Jun 15;15(12).
    PMID: 37376337 DOI: 10.3390/polym15122691
    Polymeric rubber and organic semiconductor H2Pc-CNT-composite-based surface- and sandwich-type shockproof deformable infrared radiation (IR) sensors were fabricated using a rubbing-in technique. CNT and CNT-H2Pc (30:70 wt.%) composite layers were deposited on a polymeric rubber substrate as electrodes and active layers, respectively. Under the effect of IR irradiation (0 to 3700 W/m2), the resistance and the impedance of the surface-type sensors decreased up to 1.49 and 1.36 times, respectively. In the same conditions, the resistance and the impedance of the sandwich-type sensors decreased up to 1.46 and 1.35 times, respectively. The temperature coefficients of resistance (TCR) of the surface- and sandwich-type sensors are 1.2 and 1.1, respectively. The novel ratio of the H2Pc-CNT composite ingredients and comparably high value of the TCR make the devices attractive for bolometric applications meant to measure the intensity of infrared radiation. Moreover, given their easy fabrication and low-cost materials, the fabricated devices have great potential for commercialization.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links