  1. Zeng Y, Xu Y, Kee CL, Low MY, Ge X
    Drug Test Anal, 2016 Mar;8(3-4):351-6.
    PMID: 26305055 DOI: 10.1002/dta.1846
    In this study, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) with scheduled multiple reaction monitoring (MRM) enhanced product ion (EPI) method was developed for simultaneous determination of 40 compounds with weight loss effect, including bisacodyl, phenolphthalein, and sibutramine and its metabolites, etc. They might be adulterated in health supplements to get prominent weight loss effect. The samples were analyzed using a Q-Trap 5500 coupled with high performance liquid chromatography (HPLC) and a CORTECS ultra performance liquid chromatography (UPLC) C18 column (100 mm x 2.1 mm x1.6 µm). Scheduled MRM was used as survey scan, MS2 spectra acquired in the EPI mode were used to perform library searching to increase the confidence of detection. Limits of detection were less than 10 ng/g for the majority of the analytes. A total of 447 weight loss products were tested in our laboratory in the past three years. Among these samples, 119 samples were found to be adulterated with one or more weight loss compounds, including sibutramine, its metabolites benzyl sibutramine and desmethyl sibutramine; phenolphthalein; bisacodyl; furosemide; liothyronine (T3); and thyroxine (T4). Copyright © 2015 John Wiley & Sons, Ltd.
  2. Mokhtar SU, Chin ST, Kee CL, Low MY, Drummer OH, Marriott PJ
    J Pharm Biomed Anal, 2016 Mar 20;121:188-196.
    PMID: 26808068 DOI: 10.1016/j.jpba.2016.01.034
    Application of gas chromatography-triple quadrupole mass spectrometry for identification, confirmation and quantification of 6 phosphodiesterase-5 (PDE-5) inhibitors (sildenafil, dimethylsildenafil, homosildenafil, thiosildenafil, thiodimethylsildenafil and thiohomosildenafil) in dietary supplements was investigated. The MS was operated in multiple reaction monitoring mode, for better sensitivity and selectivity. In this manner, the method is adequate to reduce background noise with less interference from co-eluting compounds in the samples. Two different ionisation techniques, electron ionisation (EI) and chemical ionisation (CI), were studied and compared. The chromatographic separation was performed on a short 10 m non-polar capillary column without any derivatisation step. This permitted fast analysis for all analogues with retention time less than 11 min, for both techniques. Use of backflushing can aid method retention time reduction and improves column maintenance. Evaluation of method validation included limit of detection (LOD), lower limit of quantitation (LLOQ), linearity, precision and recovery were performed for both EI and CI techniques. The LOD obtained varied from 0.03 to 1.50 μg/g and the LLOQ ranged from 0.10 to 5.00 μg/g. Good calibration linearity was obtained for all analogues for both techniques, with correlation coefficients (r(2)) higher than 0.99. Mean recoveries of all analogues using CI show higher values (83.4-108.8%) than that of EI (61.9-91.1%). The intra- and inter-assay precisions were evaluated for all analogues at spiked concentration of 10 μg/g and the relative standard deviation was less than 15% for both methods. These methods were then successfully applied to dietary supplement samples without prior derivatisation, confirming that the samples were adulterated with sildenafil and/or its analogues.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links