  1. Muralidharan S, Kumar JR, Dhanara SA
    J Adv Pharm Technol Res, 2013 Jan;4(1):65-8.
    PMID: 23662284 DOI: 10.4103/2231-4040.107503
    A high-performance liquid chromatographic (HPLC) and ultraviolet (UV) methods were developed and validated for the quantitative determination of Ambroxol hydrochloride (AMH) in pharmaceutical dosage form. HPLC was carried out by reversed phase (RP) technique on an RP-18 column with a mobile phase composed of acetonitrile and water (pH 3.5 adjusted with orthophosphoric acid [60:40, v/v]). UV method was performed with the λmax at 250 nm. Both the methods showed good linearity, reproducibility, and precision. No spectral or chromatographic interferences from the tablet excipients were found in UV and HPLC. The method was successfully applied to commercial tablets. Validation parameters such as linearity, precision, accuracy, and specificity were determined. The HPLC Limit of detection (LOD) and Limit of quantification (LOQ) for Ambroxol were found to be 1 and 5 ng/ml, respectively. The UV LOD and LOQ for Ambroxol were found to be 1 and 4 μg/ml, respectively. The results were statistically compared using one-way analysis of variance. The proposed economical method could be applicable for routine analysis of AMH and monitoring of the quality of marketed drugs.
  2. Muralidharan S, Kumar Jr, Dhanaraj SA
    Pak J Pharm Sci, 2015 Jan;28(1):135-8.
    PMID: 25553676
    Simple and effective high performance liquid chromatographic (HPLC) method was developed for estimation of Clindipine in drug free human drug free blank plasma. The internal standard used as Nifidipine (IS). The current method was used protein precipitating extraction of Clindipine from blank plasma. Separation was achieved on reversed-phase c18 column (25cm × 4.6mm, 5μ) and the detection was monitored by UV detector at 260 nm. The optimized mobile phase was used acetonitrile: 5mM potassium dihydrogen orthophosphate (pH 4.5), in the ratio of 60:40% v/v at a flow rate of 1.0 ml/min. This linearity was achieved in this method range of 10.0-125.0 ng/ml with regression coefficient range is 0.99. The present method is suitable in terms of precise, accurate and specific during the study. The simplicity of the method allows for application in laboratories that lack sophisticated analytical instruments such as LC-MS/MS or GC-MS/MS that are complicated, costly and time consuming rather than a simple HPLC-UV method. The present method was successfully applied for pharmacokinetic studies.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links