Displaying all 6 publications

Abstract:
Sort:
  1. Siow J, Kwek E
    Malays Orthop J, 2021 Jul;15(2):101-106.
    PMID: 34429829 DOI: 10.5704/MOJ.2107.015
    Introduction: The morphology of the proximal femur differs in various populations. Based on our clinical experience, conventional femoral stems used in hip arthroplasty do not fit the Chinese population well. Hence, this study aims to evaluate the suitability of conventional femoral stems in the elderly Chinese hip fracture population requiring hip arthroplasty and to establish if gender and age related differences exist within this population.

    Material and Methods: We retrospectively analysed radiographic data of 300 patients from a tertiary hospital's geriatric hip fracture database who underwent either hip hemi-arthroplasties or total hip arthroplasties. Proximal femur morphological measurements were recorded, analysed and compared to that of commonly used femoral stems. Subgroup analysis was performed to compare age and gender related differences.

    Results: A total of 18.3% of the study population had a medial femoral offset (MFO) of less than 30mm, which is the smallest available offset for the implants studied. 22.6% of female and 3% of male subjects had MFOs that were less than 30mm. In our subgroup analysis, males had significantly larger femoral head diameters, MFO and vertical femoral offsets compared to females. Older subjects (75-90 years old) had significantly smaller femoral head diameters, vertical femoral offsets and neck shaft angles compared to younger subjects (60-75 years old).

    Conclusion: Commonly used femoral stem implants have measurements that do not suit our Chinese population with small medial femoral offsets. In addition, elderly males have significantly larger femoral head diameters, medial and vertical femoral offsets whereas older subjects have significantly smaller femoral head diameters, vertical femoral offsets and neck shaft angles.

  2. Tan K, Kwek E
    Malays Orthop J, 2020 Mar;14(1):24-27.
    PMID: 32296478 DOI: 10.5704/MOJ.2003.004
    Introduction: Orthopaedic surgeons are significantly predisposed to musculoskeletal injury, and these injuries can have negative effects on surgeon function and patient outcomes. While this phenomenon has been studied in the non-Asian population of surgeons, no study has been carried out in the local or regional Asian setting. The aim of this study was to determine the prevalence, characteristics and associations of occupational injuries in orthopaedic surgeons and residents, and to assess its functional impact.

    Materials and Methods: The Nordic Musculoskeletal Questionnaire was sent out to all orthopaedic consultants and residents at two institutions in Singapore, via an email link to an online survey. Separately, further questions on symptom description, severity and treatment were surveyed. Additional information like age, gender, height and weight were obtained as well.

    Results: A total of 87.5% respondents have at least one injury. Neck symptoms (66.1%) were the most prevalent, and back symptoms had the highest median severity score (4.5/10). The 74.1% of these injuries were reported as directly attributable to work. Age was found to be associated with an increase in the total number of anatomical areas affected (p = 0.016). A seated operating position was associated with more severe back pain (p = 0.040).

    Conclusion: There is a high prevalence of occupational injuries sustained in our population of orthopaedic surgeons. Neck symptoms, followed by back and wrist symptoms, were the predominant symptoms in our population. Targeted ergonomic interventions may be considered to prevent specific musculoskeletal injuries in our population of orthopaedic surgeons.

  3. Chan MF, Kwek E
    Malays Orthop J, 2020 Mar;14(1):81-83.
    PMID: 32296487 DOI: 10.5704/MOJ.2003.013
    Klebsiella pneumoniae is one of the leading causative organisms in pyogenic liver disease. It can cause disseminated infections, but rarely to bone, and rarely in healthy hosts. We report an unusual case of a distal humerus fracture from osteomyelitis secondary to dissemination in a non-immuno-compromised patient. The patient was surgically managed with external fixation and insertion of anti-biotic beads, in conjunction with medical therapy via culture direct antibiotics. This report highlights the diagnostic approach and treatment options for these atypical cases.
  4. Yap W, Hairodin Z, Kwek E
    Malays Orthop J, 2021 Jul;15(2):36-42.
    PMID: 34429820 DOI: 10.5704/MOJ.2107.006
    Introduction: Two common crutches utilised for orthopaedic rehabilitation include the axillary crutch and forearm crutch, with either crutch providing weight transfer through different mechanisms. This study aims to determine which crutch is best for patients, with specific reference to crutch gait and stability.

    Material and Methods: This is a level 2 prospective cohort study, recruiting 20 volunteers between 40 to 80 years old. Participants underwent 3 stations in 3 point crutch gait: straight line ambulation of 20m, timed-up-and-go-test, and computerised dynamic posturography. Participants also answered a subjective questionnaire on their crutch preferences.

    Results: Axillary crutches demonstrated a faster speed of ambulation compared to forearm crutches (Axillary crutch v=0.5m/s, Forearm crutch v=0.44m/s, p=0.002). There was a lower increase in heart rate post activity for axillary crutches. For the timed-up-and-go test, completing the circuit with Axillary crutches was faster (t=63.06, p<0.001) versus the forearm crutch (t=75.36, p<0.001). For computerised dynamic posturography, participants recorded lower effort scores for backward tilts when using axillary crutches (39.13, p=0.0497) versus forearm crutches (42.03, p=0.0497). Subjectively, majority of participants felt that axillary crutches had an easier learning curve and were superior in the areas of ambulation, balance and stability.

    Conclusion: Our study demonstrated that axillary crutches were superior to forearm crutches for 3-point crutch gait; axillary crutches had a faster ambulation speed, required less effort during use, provided superior stability and were the preferred choice subjectively. This study would be helpful for clinicians and therapists when prescribing mobility aids to individuals with impaired gait.

  5. Yuan W, Chua T, Kwek E
    Malays Orthop J, 2022 Nov;16(3):55-60.
    PMID: 36589381 DOI: 10.5704/MOJ.2211.010
    INTRODUCTION: Elective implant removal following healed extremity fractures remains controversial. This study aimed to evaluate the reasons and outcomes of implant removal after uneventful healing of limb fractures.

    MATERIALS AND METHODS: This is a prospective single-centre observational cohort study. Patients who sustained upper or lower extremity fractures that were fixed and healed uneventfully were included in the study when they elected to remove the implants. Patients were followed for six months post-operatively. Outcomes were assessed with patient satisfaction, symptoms resolution, and complications.

    RESULTS: A total of 43 patients were recruited from October 2016 to March 2019. Thirty-six patients (37 implants) were symptomatic. Pain and prominence were the most common complaints, present in 59.5% and 33.3% of patients, respectively. Cold weather pain was also not uncommon (19.0%). Pain improved in 91.3% of the patients who complained of pain. The 94.6% symptomatic patients had at least partial resolution of pre-operative symptoms. All the patients who completed follow-up were satisfied with the procedure. In two patients, there were broken and retained screws intra-operatively. Post-operative complication rate was 23.8%, although no major complications occurred.

    CONCLUSIONS: Implant removal after uneventful healing of extremity fractures is a safe procedure that conferred a predictable relief of symptoms and satisfactory outcomes in most.

  6. Yap W, Ng JW, Lee M, Kwek E
    Malays Orthop J, 2024 Mar;18(1):140-149.
    PMID: 38638650 DOI: 10.5704/MOJ.2403.018
    INTRODUCTION: Minimally invasive percutaneousosteosynthesis (MIPO) plating techniques havedemonstrated good outcomes in the treatment of distal tibia fractures. Early arthritis and functional impairment mayoccur if length and rotation are not restored. This study aims to determine the incidence and severity of tibia malrotation following MIPO plating of isolated unilateral distal tibia fractures, defined as torsional difference of greater than 10° as compared to the contralateral limb and whether the degree of malrotation affects functional outcomes scores.

    MATERIALS AND METHODS: This was a level 2 prospective cohort study. All patients with fractures of the distal tibia who underwent surgical fixation with the exclusion ofpatients with polytrauma, neurovascular injuries or pre-existing disabilities were recruited. Patients underwent MIPO plating followed by a post-operative ComputedTomography (CT) scan of bilateral lower limbs. AOFAS ankle-hindfoot score was recorded at six months and one year follow-up.

    RESULTS: A total of 24 patients (28 to 83 years old) were recruited. Nineteen patients obtained CT scans. Nine of the 19 patients (47.3%) had tibia malrotation. The mean tibia malrotation angle was 10.3° (0° - 45°). The average AOFAS scores was 82.4 and 84.3 at 6 months and 1 year follow-up. Degree of CT malrotation was not significantly associated with AOFAS scores at 6 month (spearman rho -0.386) and 1 year (spearman rho -0.343).

    CONCLUSIONS: Tibia malrotation following MIPO plating of distal tibia fractures is common, with an incidence of 47.3% and an average malrotation angle of 10.3°. The degree of malrotation does not appear to have significant mid-term functional impact on the patient.