Displaying all 2 publications

Abstract:
Sort:
  1. Wong JJM, Lee SW, Tan HL, Ma YJ, Sultana R, Mok YH, et al.
    Pediatr Crit Care Med, 2020 08;21(8):720-728.
    PMID: 32205663 DOI: 10.1097/PCC.0000000000002324
    OBJECTIVES: Reduced morbidity and mortality associated with lung-protective mechanical ventilation is not proven in pediatric acute respiratory distress syndrome. This study aims to determine if a lung-protective mechanical ventilation protocol in pediatric acute respiratory distress syndrome is associated with improved clinical outcomes.

    DESIGN: This pilot study over April 2016 to September 2019 adopts a before-and-after comparison design of a lung-protective mechanical ventilation protocol. All admissions to the PICU were screened daily for fulfillment of the Pediatric Acute Lung Injury Consensus Conference criteria and included.

    SETTING: Multidisciplinary PICU.

    PATIENTS: Patients with pediatric acute respiratory distress syndrome.

    INTERVENTIONS: Lung-protective mechanical ventilation protocol with elements on peak pressures, tidal volumes, end-expiratory pressure to FIO2 combinations, permissive hypercapnia, and permissive hypoxemia.

    MEASUREMENTS AND MAIN RESULTS: Ventilator and blood gas data were collected for the first 7 days of pediatric acute respiratory distress syndrome and compared between the protocol (n = 63) and nonprotocol groups (n = 69). After implementation of the protocol, median tidal volume (6.4 mL/kg [5.4-7.8 mL/kg] vs 6.0 mL/kg [4.8-7.3 mL/kg]; p = 0.005), PaO2 (78.1 mm Hg [67.0-94.6 mm Hg] vs 74.5 mm Hg [59.2-91.1 mm Hg]; p = 0.001), and oxygen saturation (97% [95-99%] vs 96% [94-98%]; p = 0.007) were lower, and end-expiratory pressure (8 cm H2O [7-9 cm H2O] vs 8 cm H2O [8-10 cm H2O]; p = 0.002] and PaCO2 (44.9 mm Hg [38.8-53.1 mm Hg] vs 46.4 mm Hg [39.4-56.7 mm Hg]; p = 0.033) were higher, in keeping with lung protective measures. There was no difference in mortality (10/63 [15.9%] vs 18/69 [26.1%]; p = 0.152), ventilator-free days (16.0 [2.0-23.0] vs 19.0 [0.0-23.0]; p = 0.697), and PICU-free days (13.0 [0.0-21.0] vs 16.0 [0.0-22.0]; p = 0.233) between the protocol and nonprotocol groups. After adjusting for severity of illness, organ dysfunction and oxygenation index, the lung-protective mechanical ventilation protocol was associated with decreased mortality (adjusted hazard ratio, 0.37; 95% CI, 0.16-0.88).

    CONCLUSIONS: In pediatric acute respiratory distress syndrome, a lung-protective mechanical ventilation protocol improved adherence to lung-protective mechanical ventilation strategies and potentially mortality.

  2. Wong JJM, Tan HL, Sultana R, Ma YJ, Aguilan A, Lee SW, et al.
    Front Pediatr, 2022;10:993175.
    PMID: 36483473 DOI: 10.3389/fped.2022.993175
    BACKGROUND: The longitudinal course of patients with pediatric acute respiratory distress syndrome (PARDS) is not well described. In this study, we describe the oxygenation index (OI) and oxygen saturation index (OSI) in mild, moderate, and severe PARDS over 28 days and provide pilot data for the time to resolution of PARDS (T res), as a short-term respiratory-specific outcome, hypothesizing that it is associated with the severity of PARDS and clinical outcomes.

    METHODS: This prospective observational study recruited consecutive patients with PARDS. OI and OSI were trended daily over 28 days. T res (defined as OI 

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links