Results: Based on MRI, Thessaly was the most sensitive for medial meniscus tears (56.2%), while McMurray and joint-line tenderness were more specific (89.1% and 88.0%, respectively). For lateral meniscus tears, McMurray was the most sensitive (56.2%) and all were specific (McMurray 89.6%, Thessaly 88.4%, joint-line tenderness 90.2%). With arthroscopy, Thessaly was the most sensitive for medial meniscus (76.6%), while McMurray and joint-line tenderness were more specific (81.0%, and 81.0%). Agreement with arthroscopy was the highest with McMurray (for medial meniscus kappa=0.40, p<0.001, and for lateral meniscus kappa=0.38, p=0.002).
Conclusion: The Thessaly can be used to screen for medial meniscus tears. McMurray and joint-line tenderness should be used for suspected medial meniscus tears. For lateral meniscus, McMurray is appropriate for screening and all the tests are useful in clinic.