Displaying all 2 publications

Abstract:
Sort:
  1. Mohd Aizam Talib, Nor Asiah Muhamad, Zulkurnain Abdul Malek
    MyJurnal
    Preventive tests and diagnosis of in-service power transformer are important for early fault prediction and increased reliability of electricity supply. However, some existing diagnostic techniques require transformer outage before the measurement can be performed and need expert knowledge and experiences to interpret the measurement results. Other measurement techniques such as chemical analyses of insulating oil may cause significant variance to measurement results due to different practices in oil sampling, storage, handling and transportation of oil. A cost-effective measuring technique, which is simple, providing fast and an accurate measurement results, is therefore highly required. The extended application of Polarisation and Depolarisation (PDC) measurement for characterisation of different faults conditions in-service power transformer has been presented in this paper. Earlier studies on polarisation and depolarisation current of oil samples from in-service power transformer shows that depolarisation has provided significant information about the change of material properties due to faults in power transformer. In this paper, a new approach based on Depolarisation Current Ratio Index (DRI) was developed for identifying and classifying different transformer fault conditions. The DRI at time interval of 4s to 100s was analysed and the results show that DRI of depolarisation current between 5/100s and 10/100s provides higher correlation on the incipient faults in power transformer.
  2. Saiful Mohammad Iezham Suhaimi, Nouruddeen Bashir, Nor Asiah Muhamad, Mohd Aizam Talib
    MyJurnal
    Contaminated and ageing transmission line insulators often suffer from temporary or permanent loss of their insulating properties due to flashover resulting in power system failure. Surface discharges are precursors to flashover. To pre-empt any occurrence of flashovers, utility companies monitor the conditions of their insulators. There are numerous insulator surface monitoring techniques such as Leakage Current, Acoustics, and Infrared. However, these techniques may not be suitable for in-situ condition monitoring of the insulators as they are prone to noise, affected by environmental conditions or contact methods. Monitoring of the UV signals emitted by the surface discharges of these insulators has been reported to be a promising technique. However, comprehensive studies on this technique is lacking, especially on aged insulators. This paper investigated the UV signals of contaminated and aged insulators detected during surface discharge activities using UV pulse method. The time and frequency domain of the UV signals were analysed for a group of insulator samples having varying levels of contamination and phases of ageing. Results show that there is a strong correlation between the contamination level and ageing of the insulators with the amplitude and harmonic components of the UV signals. This correlation can useful to monitor in-service insulator surface conditions.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links