CASE PRESENTATION: This is a retrospective review of clinical presentations, radiographic findings, histopathological findings, treatments, and outcomes of patients who developed delayed complications in orbital blowout fracture repair using porous polyethylene sheets. Four male patients were included with a mean age of 49 years (range 35-69 years). Blowout fracture repair was complicated with implant-related inflammation 10 months, 2 years, 3 years, and 8 years after surgery. Chronic and subacute orbital inflammatory signs were noted in two patients and acute fulminant orbital inflammation was found in two patients. Three patients developed peri-implant abscesses and one patient had a soft tissue mass around the implant. All patients underwent implant removal and two of these patients with paranasal sinusitis had sinus surgery. Histopathological findings revealed chronic inflammatory changes with fibrosis, and one patient had foreign body granuloma with culture positive Staphylococcus aureus.
CONCLUSIONS: Delayed complications with porous polyethylene sheets used in orbital blowout fracture repair may occur many years following the initial surgery in immunocompetent patients. Low-grade or fulminant inflammation could complicate blowout fracture repair related with the implant.
DESIGN: Prospective cross-sectional study.
METHODS: Consecutive CSC patients were recruited from retina clinic. The reference standard for CNV was determined by interpretation of multimodal imaging with OCTA, structural OCT line scan, fluorescein angiography (FA), indocyanine green angiography (ICGA), ultra-widefield fundus photography and fundus autofluorescence (FAF). Two independent masked graders examined OCTA without FA and ICGA to diagnose CNV. Univariate and multivariate analyses were performed to evaluate factors associated with CNV.
RESULTS: CNV was detected in 69 eyes in 64 out of 277 CSC patients according to reference standard. The two masked graders who examined OCTA had sensitivity of 81.2% (95% Confidence Interval [CI], 71.9%-90.4%) and 78.3% (95% CI, 68.5%-88.0%), specificity of 97.3% (95% CI, 95.9%-98.8%) and 96.2% (95% CI, 94.5%-98.0%), positive predictive values of 82.4% (95% CI, 73.3%-91.4%) and 76.1% (95% CI, 66.1%-86.0%), and negative predictive values of 97.1% (95% CI, 95.6%-98.7%) and 96.7% (95% CI, 95.0%-98.3%). Their mean area under the receiver operating characteristic curve (AUC) was 0.88 with good agreement (Kappa coefficient 0.80 [95% CI, 0.72-0.89]). Flat irregular pigment epithelial detachment on structural OCT, neovascular network on OCTA and ill-defined late leakage on FA significantly correlated with CNV in CSC from multiple regression (P < 0.001, P < 0.001 and P = 0.005, respectively).
CONCLUSIONS: There is discordance between OCTA and multimodal imaging in diagnosing CNV in CSC. This study demonstrated the caveats in OCTA interpretation, such as small extrafoveal lesions and retinal pigment epithelial alterations. Comprehensive interpretation of OCTA with dye angiography and structural OCT is recommended.
METHODS: Both eyes of patients with myopic MNV diagnosed with fluorescein angiography (FA), SD OCT and OCTA were assessed by unmasked investigators. The images were deidentified and randomised before graded by masked investigators, who determined the presence of active myopic MNV by using SD OCT together with OCTA without FA and by FA alone, respectively. The findings of masked investigators were compared with unmasked investigators.
RESULTS: 213 eyes of 110 patients comprising 499 imaging episodes were eligible for grading. For diagnosing new-onset myopic MNV without FA, combined use of SD OCT and OCTA had a sensitivity of 0.94, specificity of 0.84 and area under the curve (AUC) of 0.92. FA had a sensitivity of 0.52 (p<0.01), specificity of 0.80 (p=0.38) and AUC of 0.66 (p<0.01). For recurrent myopic MNV, the combination of SD OCT and OCTA had a sensitivity of 0.98, specificity of 0.78 and AUC of 0.88. FA had a sensitivity of 0.50 (p=0.04), specificity of 0.76 (p=0.85) and AUC of 0.63 (p=0.01). Myopic traction maculopathy was more frequently associated with recurrent myopic MNV (p<0.01).
CONCLUSION: SD OCT with dense volumetric scan was highly sensitive for diagnosing myopic MNV. The addition of OCTA improved the diagnostic specificity without FA. Monitoring of the longitudinal changes on SD OCT and judicious use of FA is a reliable surveillance strategy for myopic MNV.