Displaying all 2 publications

Abstract:
Sort:
  1. Zal U’yun Wan Mahmood, Norfaizal Mohamed @ Mohamad, Nik Azlin Nik Ariffin, Abdul Kadir Ishak
    MyJurnal
    An improved laboratory technique for measurement of polonium-210(
    210Po) in environmental
    samples has been developed in Radiochemistry and Environmental Laboratory (RAS), Malaysian
    Nuclear Agency. To further improve this technique, a study with the objectives to determine the
    optimum conditions for
    210Po deposition and; evaluate the accuracy and precision results for
    the determination of 2 1 0 P o in environmental samples was carried-out. Polonium-210 which
    is an alpha emitter obtained in acidic solution through total digestion and dissolution of samples
    has been efficiently plated onto one side of the silver disc in the spontaneous plating process for
    measurement of its alpha activity. The optimum conditions for deposition of 210Po were achieved
    using hydrochloric acid (HCl) media at acidity of 0.5 M with the presence of 1.0 gram hydroxyl
    ammonium chloride and the plating temperature at 90
    oC. The plating was carried out in 80 mL
    HCl solution (0.5 M) for 4 hours. The recorded recoveries obtained using 2 0 9 P o tracers in
    the CRM IAEA-385 and environmental samples were 85% – 98% whereby the efficiency of the
    new technique is a distinct advantage over the existing techniques. Therefore, optimization of
    deposition parameters is a prime importance to achieve accuracy and precision results as well as
    economy and time saving
  2. Zal Uyun Wan Mahmood, Yii, Mei-Wo, Che Abd. Rahim Mohamed, Norfaizal Mohamed @ Mohamad, Abdul Kadir Ishak
    MyJurnal
    The most commonly used techniques of alpha and gamma spectrometry were performed to measure
    210Pb activity in marine sediment core as a comparison. Alpha analytical technique measured the
    activity of 210Pb from it’s in-grow grand-daughter 210Po after a chemical separation, assuming
    radioactive equilibrium between the two radionuclides. Meanwhile, gamma analysis technique
    allows direct measurement, non-destructive and no preliminary chemical separation. Through the
    comparison, it is found that both alpha and gamma analysis techniques were slightly difference.
    Overall, the results from alpha analytical technique were basically higher than those from the
    gamma analytical techniques. Some logical argument had been discussed to explain this situation.
    In routine analysis, the analytical technique used should be chosen carefully based on advantages
    and disadvantages of the each technique and analysis requirements. Therefore, it is recommended to
    determine exactly the needs and purpose of analysis and to know the sample history before decide
    the appropriate analytical technique
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links