MATERIALS AND METHODS: A total of 44 patients were included after evaluation for sleep disorders and were divided into four groups in accordance with apnea-hypopnea index (AHI). Pure tone audiometry (PTA), distortion product otoacoustic emission (DPOAE) and auditory brainstem response (ABR) were compared in commensurate with the severity of AHI. Polysomnography oximetry parameters of oxygen desaturation index, mean SPO2, minimum SPO2 and percent SPO2 V absolute latencies. Minimum SPO2 was also significantly correlated with wave III peak latency changes.
CONCLUSIONS: Mean SPO2, percent SPO2