Displaying all 2 publications

Abstract:
Sort:
  1. Shiek Ahmad B, Wark JD, Petty SJ, O'Brien TJ, Gorelik A, Sambrook PN, et al.
    Epilepsia, 2015 Nov;56(11):1714-22.
    PMID: 26513212 DOI: 10.1111/epi.13136
    To investigate cross-sectional and longitudinal differences in static and dynamic standing balance measures and lower limb muscle strength in patients who are treated chronically with antiepileptic drugs (AEDs).
  2. Shiek Ahmad B, Petty SJ, Gorelik A, O'Brien TJ, Hill KD, Christie JJ, et al.
    Osteoporos Int, 2017 Sep;28(9):2591-2600.
    PMID: 28589417 DOI: 10.1007/s00198-017-4098-9
    Changes in areal bone mineral density (aBMD) and other predictors of bone loss were evaluated in 48 same-sex twin/age-matched sibling pairs discordant for antiepileptic drug (AED) use. AED users had reduced BMD at the hip regions. Prolonged AED users had greater aBMD loss, predicting a higher risk of bone fragility.

    INTRODUCTION: To investigate the longitudinal associations of bone mineral measures with antiepileptic drug (AED) use, including enzyme-inducing (EIAED) and non-enzyme-inducing (NEIAED) types, and other predictors of bone loss in a study of 48 same-sex twin/age-matched sibling pairs (40 female, 8 male) discordant for AED use.

    METHODS: Using dual-energy X-ray absorptiometry (DXA), areal bone mineral density (aBMD) and content (BMC) at the hip regions, forearm, lumbar spine, and whole body were measured twice, at least 2 years apart. The mean within-pair difference (MWPD), MWPD%, and mean annual rate of aBMD change were adjusted for age, weight, and height. Predictors of bone loss were evaluated.

    RESULTS: AED users, compared to non-users, at baseline and follow-up, respectively, had reduced aBMD at the total hip (MWPD% 3.8, 4.4%), femoral neck (4.7, 4.5%), and trochanter regions (4.1, 4.6%) (p  0.05) regions did not differ within pairs. Nevertheless, EIAED users had greater aBMD loss than non-users (n = 20 pairs) at the total hip (1.7 vs. 0.3%, p = 0.013) and whole body regions (0.7% loss vs. 0.1% BMD gain, p = 0.019), which was not found in NEIAED-discordant pairs (n = 16). AED use >20 years predicted higher aBMD loss at the forearm (p = 0.028), whole body (p = 0.010), and whole body BMC (p = 0.031).

    CONCLUSIONS: AED users had reduced aBMD at the hip regions. Prolonged users and EIAED users had greater aBMD loss, predicting a higher risk of bone fragility. Further prospective studies of AED effects on bone microarchitecture are needed.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links