  1. Jadhav V, Deshpande S, Radke U, Mahale H, Patil PG
    J Prosthet Dent, 2021 Oct;126(4):590-594.
    PMID: 33012529 DOI: 10.1016/j.prosdent.2020.07.014
    STATEMENT OF PROBLEM: Xerostomia refers to the decrease in the quality and quantity of saliva. In denture wearers, xerostomia affects the retention of the denture because of lack of wettability of the denture base. However, which denture base resin materials are best wetted by artificial salivary substitutes is unclear.

    PURPOSE: The purpose of this in vitro study was to determine the wetting properties of 3 different commercially available denture base resin materials with artificial salivary substitute by using contact angle measurements and to compare these properties before and after thermocycling.

    MATERIAL AND METHODS: A total 120 specimens were fabricated with 3 different denture base materials (n=40): heat-polymerized polymethylmethacrylate (DenTek), injection-molded nylon polyamide (Valplast), and microwave polymerized (VIPI WAVE). The advancing and receding contact angles were measured with a goniometer by using the WinDrop++ software program. The contact angle hysteresis was calculated from the advancing and receding contact angles values. The same specimens were subjected to thermocycling to measure the advancing and receding contact angles values. The comparative evaluation was carried out before and after thermocycling.

    RESULTS: The mean ±standard deviation contact angles of the microwave-polymerized material were (62.40 ±1.21 degrees) advancing contact angle, (32.12 ±0.66 degrees) receding contact angle, and (30.28 ±1.40 degrees) contact angle of hysteresis. It was followed by the injection-molded nylon polyamide material, whose mean ±standard deviation contact angle values were (68.57 ±1.72 degrees) advancing contact angle, (43.02 ±1.39 degrees) receding contact angle, (26.27 ±2.05 degrees) contact angle hysteresis and high impact strength heat-polymerized polymethylmethacrylate material, whose mean ±standard deviation contact angle values were (69.81 ±0.16 degrees) advancing contact angle, (41.90 ±1.02 degrees) receding contact angle, and (27.91 ±0.97 degrees) contact angle hysteresis. The statistical analysis showed significant differences among contact angle values of the microwave-polymerized material as compared with the heat-polymerized polymethylmethacrylate and injection-molded nylon polyamide materials (P

  2. Deshpande S, Chandak A, Radke U, Mahalle H, Patil PG
    J Maxillofac Oral Surg, 2022 Dec;21(4):1175-1179.
    PMID: 36896084 DOI: 10.1007/s12663-022-01727-0
    BACKGROUND: Considering the two-implant-retained overdenture as a first treatment of choice for edentulous mandible, patients using the overdentures need to be satisfied with the type of attachment used. The purpose of this study was to determine level of patient satisfaction with two-implant-retained mandibular overdentures opposing conventional maxillary complete denture using ball-socket and bar-clip attachments.

    MATERIALS AND METHODS: In this within-subject crossover randomized clinical trial, total 20 edentulous patients were given conventional complete dentures for 3 months to use. All completed a satisfaction questionnaire before implant placement. They were randomly assigned to receive an overdenture retained by either ball or bar attachment. After 3 months satisfaction questionnaires were repeated, and crossover was done by changing the attachments. After use of 3 months of alternate attachments, patients were asked to complete the final questionnaires and asked to choose their preferred type. The patient satisfaction scores were recorded after using 3 months of conventional complete denture, 3 months of first attachment and 3 months of second attachment. Data were analyzed using Wilcoxon signed rank test. The P values were adjusted using Bonferroni multiple testing correction, and P 