Displaying all 4 publications

Abstract:
Sort:
  1. Leschke M, Waliszewski M, Pons M, Champin S, Nait Saidi L, Mok Heang T, et al.
    Catheter Cardiovasc Interv, 2016 Sep;88(3):358-66.
    PMID: 26650913 DOI: 10.1002/ccd.26261
    OBJECTIVES: This observational study assessed the 9-month clinical outcomes in an « all comers » population with a focus on patients with atrial fibrillation (AF) after thin strut bare metal stenting.

    BACKGROUND: Drug eluting stent (DES) implantation is the treatment of choice for coronary artery disease (CAD) leaving only marginal indications for the use of bare metal stents (BMS). However, selected treatment populations with DES contraindications such as patients who cannot sustain 6-12 months of dual antiplatelet therapy (DAPT) remain candidates for BMS implantations.

    METHODS: Thin strut bare metal stenting in a priori defined subgroups were investigated in a non-randomized, international, multicenter «all comers» observational study. Primary endpoint was the 9-month TLR rate whereas secondary endpoints included the 9-month MACE and procedural success rates.

    RESULTS: A total of 783 patients of whom 98 patients had AF underwent BMS implantation. Patient age was 70.4 ± 12.8 years. Cardiovascular risk factors in the overall population were male gender (78.2%, 612/783), diabetes (25.2%, 197/783), hypertension (64.1%, 502/783), cardiogenic shock (4.9%, 38/783) and end stage renal disease (4.9%, 38/783). In-hospital MACE was 4.1% (30/783) in the overall population. The 9-month TLR rate was 4.5% (29/645) in the non-AF group and 3.3% (3/90) in the AF group (P = 0.613). At 9 months, the MACE rate in the AF-group and non-AF group was not significantly different either (10.7%, 69/645 vs. 6.7%, 6/90; P = 0.237). Accumulated stroke rates were 0.3% (2/645) in the non-AF subgroup at baseline and 1.1% (1/90) in the AF subgroup (P = 0.264).

    CONCLUSION: Bare metal stenting in AF patients delivered acceptably low TLR and MACE rates while having the benefit of a significantly shorter DAPT duration in a DES dominated clinical practice. © 2015 Wiley Periodicals, Inc.

  2. Krackhardt F, Waliszewski M, Kočka V, Toušek P, Janek B, Hudec M, et al.
    Cardiovasc Drugs Ther, 2020 06;34(3):335-344.
    PMID: 32212061 DOI: 10.1007/s10557-020-06963-5
    OBJECTIVES: The objective of this post hoc analysis was to analyze real-world dual antiplatelet therapy (DAPT) regimens following polymer-free sirolimus-eluting stent (PF-SES) implantations in an unselected patient population.

    METHODS: Patient-level data from two all-comers observational studies (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were pooled and analyzed in terms of their primary endpoint. During the data verification process, we observed substantial deviations from DAPT guideline recommendations. To illuminate this gap between clinical practice and guideline recommendations, we conducted a post hoc analysis of DAPT regimens and clinical event rates for which we defined the net adverse event rate (NACE) consisting of target lesion revascularization (TLR, primary endpoint of all-comers observational studies) all-cause death, myocardial infarction (MI), stent thrombosis (ST), and bleeding events. A logistic regression was utilized to determine predictors why ticagrelor was used in stable coronary artery disease (CAD) patients instead of the guideline-recommended clopidogrel.

    RESULTS: For stable CAD, the composite endpoint of clinical, bleeding, and stent thrombosis, i.e., NACE, between the clopidogrel and ticagrelor treatment groups was not different (5.4% vs. 5.1%, p = 0.745). Likewise, in the acute coronary syndrome (ACS) cohort, the NACE rates were not different between both DAPT strategies (9.2% vs. 9.3%, p = 0.927). There were also no differences in the accumulated rates for TLR, myocardial infarction ([MI], mortality, bleeding events, and stent thrombosis in elective and ACS patients. The main predictors for ticagrelor use in stable CAD patients were age

  3. Krackhardt F, Kočka V, Waliszewski M, Toušek P, Janek B, Trenčan M, et al.
    Medicine (Baltimore), 2020 Feb;99(8):e19119.
    PMID: 32080086 DOI: 10.1097/MD.0000000000019119
    Stent designs with ultrathin struts may further increase the procedural success of challenging lesion subsets. The objective of this study was to assess the safety and efficacy of ultrathin strut, polymer-free sirolimus eluting stent (PF-SES) implantations in a large scale, unselected patient population.Adult patients underwent percutaneous coronary interventions (PCI) with a thin-strut PF-SES. Data from two all-comers observational studies having the same protocol (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were pooled. The accumulated target lesion revascularization (TLR) rate at 9-12 months was the primary endpoint. All dual antiplatelet therapy strategies according to the applicable guidelines were permissible.In total, 7243 patients were prospectively enrolled for PCI with PF-SES in stable coronary artery disease or acute coronary syndrome (ACS). Major risk factors in the overall cohort were diabetes (37.3%), ST elevation myocardial infarction (18.1%) and non-ST myocardial infarction (24.6%). The follow-up rate was 88.6% in the overall population. The TLR rate in the overall cohort was 2.2% whereas definite/probable stent thrombosis (ST) occurred in 0.7%. In patients with in-stent restenosis lesions, the major adverse cardiac events rate was 6.4% whereas the corresponding rate for isolated left main coronary artery (LMCA) disease was highest with 6.7% followed by patients with culprit lesions in vein bypasses (VB, 7.1%). The mortality rate in patients treated in VB lesions was highest with 5.4%, followed by the isolated LMCA subgroup (3.4%) and ACS (2.6%).PCI with PF-SES in an unselected patient population, is associated with low clinical event and ST rates. Furthermore, PF-SES angioplasty in niche indications demonstrated favorable safety and efficacy outcomes with high procedural success rates.
  4. Krackhardt F, Waliszewski M, Wan Ahmad WA, Kočka V, Toušek P, Janek B, et al.
    PLoS One, 2020;15(1):e0226606.
    PMID: 31929543 DOI: 10.1371/journal.pone.0226606
    BACKGROUND: The objective of this study was to assess regional and ethnic differences in an unselected patient population treated with polymer-free sirolimus-eluting stents (PF-SES) in Asia and Europe.

    METHODS: Two all-comers observational studies based on the same protocol (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were combined for data analysis to assure sufficient statistical power. The primary endpoint was the accumulated target lesion revascularization (TLR) rate at 9-12 months.

    RESULTS: Of the total population of 7243 patients, 44.0% (3186) were recruited in the Mediterranean region and 32.0% (2317) in central Europe. The most prominent Asian region was South Korea (17.6%, 1274) followed by Malaysia (5.7%, 413). Major cardiovascular risk factors varied significantly across regions. The overall rates for accumulated TLR and MACE were low with 2.2% (140/6374) and 4.4% (279/6374), respectively. In ACS patients, there were no differences in terms of MACE, TLR, MI and accumulated mortality between the investigated regions. Moreover, dual antiplatelet therapy (DAPT) regimens were substantially longer in Asian countries even in patients with stable coronary artery disease as compared to those in Europe.

    CONCLUSIONS: PF-SES angioplasty is associated with low clinical event rates in all regions. Further reductions in clinical event rates seem to be associated with longer DAPT regimens.

Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links