Displaying all 2 publications

Abstract:
Sort:
  1. Leelasestaporn C, Thuwapitchayanant M, Sirithanapipat P, Sa-Ngasoongsong P, Ruengsilsuwit P
    Malays Orthop J, 2021 Mar;15(1):79-84.
    PMID: 33880152 DOI: 10.5704/MOJ.2103.012
    Introduction: The aim of this study was to evaluate the reliability of the femoral component rotation on intra-operative data recorded in a computer-assisted navigation system (CAN-FRA) compared with the post-operative femoral component rotation observed on computed tomography (CT-FRA).

    Material and method: Computer-assisted total knee arthroplasty (TKA) or primary osteoarthritis of the knee was performed in 51 knees in 36 patients with a mean age of 69.51 years. All procedures were performed by a single surgeon using the same implant design. The intraclass correlation coefficient (ICC) was used to compare the intra-operative CAN-FRA with the post-operative CT-FRA. The angle between the anatomical epicondylar axis and the posterior condylar axis of the implant (CT-FRA) was measured at two separate timepoints by three observers who were blinded to the intra-operative CAN-FRA. Internal rotation was defined as rotation in the negative direction, while external rotation was defined as positive.

    Results: The mean intra-operative CAN-FRA was 0.1° ± 2.8° (range -5.0° to 5.5°). The mean post-operative CT-FRA was -1.3° ± 2.1° (range -4.6° to 4.4°). The mean difference between the CAN-FRA and the CT-FRA was -1.3° ± 2.2° (range -7.9° to 2.4°). The respective ICC values for the three observers were 0.92, 0.94, and 0.93, while the respective intra-observer coefficients were 0.91, 0.85, and 0.90. The ICC for the intra-operative CAN-FRA versus the post-operative CT-FRA was 0.71.

    Conclusion: This study shows that using a computer-assisted navigation system in TKA achieves reliable results and helps to achieve optimal positioning of the femoral component and rotation alignment correction.

  2. Sa-Ngasoongsong P, Chulsomlee K, Wongsak S, Suphachatwong C, Kawinwonggowit V
    Malays Orthop J, 2016 Nov;10(3):52-55.
    PMID: 28553451 DOI: 10.5704/MOJ.1611.012
    Patellar fracture after total knee replacement (TKR) is one of the challenging problems in periprosthetic fracture. Open reduction with internal fixation (ORIF), as tension band wiring (TBW), usually required in cases with extensor mechanism disruption. However, many studies reported a high failure rate after using this technique. In this report, we presented an interesting case of periprosthetic patellar fracture after TKR with TBW failure that was successfully treated with double non-locking reconstruction plates fixation and TBW augmentation.