Displaying all 3 publications

Abstract:
Sort:
  1. Siew QY, Pang EL, Loh HS, Tan MTT
    Biosens Bioelectron, 2021 Mar 15;176:112895.
    PMID: 33358432 DOI: 10.1016/j.bios.2020.112895
    This study reports on the development of a novel impedimetric immunosensor design using plant-derived antigenic glycoprotein for the detection of dengue virus (DENV) IgG antibodies. The electrochemical immunosensor platform was constructed using screen-printed carbon electrode (SPCE) modified with graphene/titanium dioxide (G/TiO2) nanocomposite to improve the electrode in terms electrochemical performance and specific surface area. A plant-derived dengue envelope domain III (EDIII) protein was used as the antigenic probe protein in this immunosensing strategy. Under optimised sensing conditions, the immunosensor demonstrated high sensitivity towards DENV IgG in a wide linear working range (62.5-2000 ng/mL), with a limit of detection of 2.81 ng/mL. The immunosensor showed high specificity for discriminating DENV IgG against antibodies of other infectious disease, including the closely related Zika virus (ZIKV). The reliability of the immunosensor in serological diagnosis was verified by challenging the immunosensor against serum samples, compared to conventional enzyme-linked immunosorbent assay (ELISA). As shown by its remarkable performance throughout the study, the devised immunosensor is proposed as a reliable and practical diagnostic tool for the serological detection of dengue in realistic applications.
  2. Siew QY, Tan SH, Pang EL, Loh HS, Tan MTT
    Analyst, 2021 Mar 21;146(6):2009-2018.
    PMID: 33523052 DOI: 10.1039/d0an02219e
    The envelope glycoprotein domain III (EDIII) of dengue virus (DENV) has been recognised as the antigenic region responsible for receptor binding. In the present work, we have proposed a novel immunosensor constructed on a graphene-coated screen-printed carbon electrode (SPCE) using plant-derived EDIII as the probe antigen to target DENV IgG antibodies. The developed immunosensor demonstrated high sensitivity towards DENV IgG within a wide linear working range (125-2000 ng mL-1) under the optimised sensing conditions. The limit of detection was determined to be 22.5 ng mL-1. The immunosensor also showed high specificity towards DENV IgG, capable of differentiating DENV IgG from the antibodies of other infectious diseases including the similarly structured Zika virus (ZIKV). The ability of the immunosensor to detect dengue antibodies in serum samples was also verified by conducting tests on mouse serum samples. The proposed immunosensor was able to provide a binary (positive/negative) response towards the serum samples comparable to the conventional enzyme-linked immunosorbent assay (ELISA), indicating promising potential for realistic applications.
  3. Siew QY, Tham SY, Loh HS, Khiew PS, Chiu WS, Tan MTT
    J Mater Chem B, 2018 Feb 28;6(8):1195-1206.
    PMID: 32254180 DOI: 10.1039/c7tb02891a
    Highly sensitive and selective immunosensors that can detect disease biomarkers at ultra-low levels in early stages are urgently needed to reduce mortality risks. A facile and efficient approach using sonochemical-assisted solvent graphene exfoliation and a hydrothermal synthesis method has been used to prepare graphene/titanium dioxide (G/TiO2) nanocomposites. Nanocomposites containing different ratios of graphene and TiO2 precursors were prepared to determine the optimum composition of G/TiO2 that has the highest conductivity and electrocatalytic properties. Characterisation methods such as X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), transmission electron microscopy (TEM), and high resolution TEM (HRTEM) were used to study the crystallinity, surface characteristics, elemental composition, and morphology of the synthesised nanocomposites. The synthesised materials were also confirmed via Raman spectroscopy. Using ferricyanide as the redox active probe, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) analyses indicated that 1 : 8 ratio of G/TiO2 exhibited the best current response and the lowest charge transfer resistance (Rct) of 1525 Ω. The potential of G/TiO2 for electrochemical sensing application was investigated using hydrogen peroxide (H2O2), a by-product of most enzymatic processes, as the analyte of interest. The sensitivity of the sensor towards H2O2 was 0.557 μA mM-1, with a limit of detection (LOD) at 56.89 μM. An in vitro cell proliferation assay was carried out to investigate the biocompatibility of the nanocomposites. The half-maximal inhibitory concentration (IC50) values obtained were >500 μg ml-1 for human lung fibroblasts (MRC5) and 5-25 μg ml-1 for human skin cells (HaCat).
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links