Displaying all 2 publications

Abstract:
Sort:
  1. Hasnain MS, Nayak AK, Singh M, Tabish M, Ansari MT, Ara TJ
    Int J Biol Macromol, 2016 Feb;83:71-7.
    PMID: 26608007 DOI: 10.1016/j.ijbiomac.2015.11.044
    Alginate-based bipolymeric-nanobioceramic composite matrices for sustained drug release were developed through incorporation of nano-hydroxyapatite [nHAp] powders within ionotropically-gelled calcium ion-induced alginate-poly (vinyl pyrrolidone) blends polymeric systems. nHAp powders were synthesized by precipitation technique using calcium hydroxide [Ca(OH)2] and orthophosphoric acid [H3PO4] as raw materials. The average particle size of these was synthesized. nHAp powders was found as 19.04 nm and used to prepare nHAp-alginate-PVP beads containing DS. These beads exhibited drug entrapment efficiency (%) of 65.82±1.88 to 94.45±3.72% and average bead sizes of 0.98±0.07 to 1.23±0.15 mm. These beads were characterized by scanning electron microscopy (SEM) and Fourier transform-infra red (FTIR) spectroscopy analyses. Various nHAp-alginate-PVP beads containing DS exhibited prolonged sustained drug release and followed the Koresmeyer-Peppas model of drug release (R2=0.9908-0.9978) with non-Fickian release (anomalous transport) mechanism (n=0.73-0.84) for drug release over 8 h.
  2. Hasnain MS, Ansari SA, Rao S, Tabish M, Singh M, Abdullah MS, et al.
    J Chromatogr Sci, 2017 Jul 01;55(6):587-594.
    PMID: 28335023 DOI: 10.1093/chromsci/bmx010
    The present work was employing the Quality by Design approach for the development and validation of a LC-MS-MS method to support the clinical advancement in determination of sildenafil in human plasma using lorazepam as an internal standard. Sample preparation involved solid phase extraction and calibration range observed between 3 and 1,700 ng/mL. The method was systematically optimized by employing Box-Behnken design and used mobile phase flow rate, pH and composition of mobile phase as the critical factors, and assessing the design for retention time and peak area as the responses. A substantial decrease in the variability associated with the method variables was shown in optimization studies and confirmed enhanced method robustness. The present studies revealed that developed method achieves all the regulatory requirements for linearity, accuracy, precision, selectivity, sensitivity and stability for the determination of sildenafil in human plasma. There was not any significant change in the stability of the drug shown by stability studies, performed in human plasma through freeze-thaw cycles, bench-top stability, short-term stability, long-term stability and auto sampler stability. In short, this method shows satisfactory results for the analysis of sildenafil in human plasma and possesses high degree of utility in pharmacokinetic and bioequivalence studies.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links