Displaying all 4 publications

Abstract:
Sort:
  1. Kandeel M, Alhumam MN, Al-Taher A
    Trop Biomed, 2021 Sep 01;38(3):311-317.
    PMID: 34508338 DOI: 10.47665/tb.38.3.071
    Trypanosoma evansi, the causative agent of surra or camel trypanosomiasis, is characterized by the widest geographic distribution and host range among the known trypanosomes. Its zoonotic importance and increasing evidence of drug resistance necessitate the discovery of new drug targets. The drug discovery process entails finding an exploitable difference between the host and the parasite. In this study, the thymidine metabolic pathways in camel and T. evansi were compared by analyzing their metabolic maps, protein sequences, domain and motif contents, phylogenetic relationships, and 3D structure models. The two organisms were revealed to recycle thymidine differently: performed by thymidine phosphorylase in camels (Camelus genus), this role in T. evansi was associated with nucleoside deoxyribosyltransferase (NDRT), a unique trypanosomal enzyme absent in camels. Thymidine in T. evansi seems to be governed by thymine through NDRT, whereas in camels, thymidine can be produced from thymidylate via 5'-nucleotidase. As a result, NDRT may be a promising drug target against T. evansi.
  2. Alashrah S, Kandaiya S, Maalej N, El-Taher A
    Radiat Prot Dosimetry, 2014 Dec;162(3):338-44.
    PMID: 24300340 DOI: 10.1093/rpd/nct315
    Estimation of the surface dose is very important for patients undergoing radiation therapy. The purpose of this study is to investigate the dose at the surface of a water phantom at a depth of 0.007 cm as recommended by the International Commission on Radiological Protection and International Commission on Radiation Units and Measurement with radiochromic films (RFs), thermoluminescent dosemeters and an ionisation chamber in a 6-MV photon beam. The results were compared with the theoretical calculation using Monte Carlo (MC) simulation software (MCNP5, BEAMnrc and DOSXYZnrc). The RF was calibrated by placing the films at a depth of maximum dose (d(max)) in a solid water phantom and exposing it to doses from 0 to 500 cGy. The films were scanned using a transmission high-resolution HP scanner. The optical density of the film was obtained from the red component of the RGB images using ImageJ software. The per cent surface dose (PSD) and percentage depth dose (PDD) curve were obtained by placing film pieces at the surface and at different depths in the solid water phantom. TLDs were placed at a depth of 10 cm in a solid water phantom for calibration. Then the TLDs were placed at different depths in the water phantom and were exposed to obtain the PDD. The obtained PSD and PDD values were compared with those obtained using a cylindrical ionisation chamber. The PSD was also determined using Monte Carlo simulation of a LINAC 6-MV photon beam. The extrapolation method was used to determine the PSD for all measurements. The PSD was 15.0±3.6% for RF. The TLD measurement of the PSD was 16.0±5.0%. The (0.6 cm(3)) cylindrical ionisation chamber measurement of the PSD was 50.0±3.0%. The theoretical calculation using MCNP5 and DOSXYZnrc yielded a PSD of 15.0±2.0% and 15.7±2.2%. In this study, good agreement between PSD measurements was observed using RF and TLDs with the Monte Carlo calculation. However, the cylindrical chamber measurement yielded an overestimate of the PSD. This is probably due to the ionisation chamber calibration factor that is only valid in charged particle equilibrium condition, which is not achieved at the surface in the build-up region.
  3. Younis L, Taher A, Abu-Hassan MI, Tin O
    J Contemp Dent Pract, 2009;10(4):35-42.
    PMID: 19575052
    The purpose of this study was to compare bone healing and coronal bone remodeling following both immediate and delayed placement of titanium dental implants in extraction sockets.
  4. Tan HM, Chin CM, Chua CB, Gatchalian E, Kongkanand A, Moh CL, et al.
    Asian J Androl, 2008 May;10(3):495-502.
    PMID: 18385912 DOI: 10.1111/j.1745-7262.2008.00388.x
    To evaluate the efficacy and tolerability of vardenafil, a phosphodiesterase type-5 (PDE-5) inhibitor, in men of Asian ethnicity with erectile dysfunction (ED).
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links