Displaying all 4 publications

Abstract:
Sort:
  1. Malon RS, Chua KY, Wicaksono DH, Córcoles EP
    Analyst, 2014 Jun 21;139(12):3009-16.
    PMID: 24776756 DOI: 10.1039/c4an00201f
    Lactate measurement is vital in clinical diagnostics especially among trauma and sepsis patients. In recent years, it has been shown that saliva samples are an excellent applicable alternative for non-invasive measurement of lactate. In this study, we describe a method for the determination of lactate concentration in saliva samples by using a simple and low-cost cotton fabric-based electrochemical device (FED). The device was fabricated using template method for patterning the electrodes and wax-patterning technique for creating the sample placement/reaction zone. Lactate oxidase (LOx) enzyme was immobilised at the reaction zone using a simple entrapment method. The LOx enzymatic reaction product, hydrogen peroxide (H2O2) was measured using chronoamperometric measurements at the optimal detection potential (-0.2 V vs. Ag/AgCl), in which the device exhibited a linear working range between 0.1 to 5 mM, sensitivity (slope) of 0.3169 μA mM(-1) and detection limit of 0.3 mM. The low detection limit and wide linear range were suitable to measure salivary lactate (SL) concentration, thus saliva samples obtained under fasting conditions and after meals were evaluated using the FED. The measured SL varied among subjects and increased after meals randomly. The proposed device provides a suitable analytical alternative for rapid and non-invasive determination of lactate in saliva samples. The device can also be adapted to a variety of other assays that requires simplicity, low-cost, portability and flexibility.
  2. Ulum MF, Maylina L, Noviana D, Wicaksono DH
    Lab Chip, 2016 Apr 12;16(8):1492-504.
    PMID: 27021631 DOI: 10.1039/c6lc00175k
    This study aims to observe the wicking and separation characteristics of blood plasma in a cotton thread matrix functioning as a microfluidic thread-based analytical device (μTAD). We investigated several cotton thread treatment methods using ethylenediaminetetraacetic acid (EDTA) anticoagulant solution for wicking whole blood samples and separating its plasma. The blood of healthy Indonesian thin tailed sheep was used in this study to understand the properties of horizontal wicking and separation on the EDTA-treated μTAD. The wicking distance and blood cell separation from its plasma was observed for 120 s and documented using a digital phone camera. The results show that untreated cotton-threads stopped the blood wicking process on the μTAD. On the other hand, the deposition of EDTA anticoagulant followed by its drying on the thread at room temperature for 10 s provides the longest blood wicking with gradual blood plasma separation. Furthermore, the best results in terms of the longest wicking and the clearest on-thread separation boundary between blood cells and its plasma were obtained using the μTAD treated with EDTA deposition followed by 60 min drying at refrigerated temperature (2-8 °C). The separation length of blood plasma in the μTADs treated with dried-EDTA at both room and refrigerated temperatures was not statistically different (P > 0.05). This separation occurs through the synergy of three factors, cotton fiber, EDTA anticoagulant and blood platelets, which induce the formation of a fibrin-filter via a partial coagulation process in the EDTA-treated μTAD. An albumin assay was employed to demonstrate the efficiency of this plasma separation method during a one-step assay on the μTAD. Albumin in blood is an important biomarker for kidney and heart disease. The μTAD has a slightly better limit of detection (LOD) than conventional blood analysis, with an LOD of 114 mg L(-1) compared to 133 mg L(-1), respectively. However, the μTAD performed faster to get results after 3 min compared to 14 min for centrifuged analysis of sheep blood samples. In conclusion, on-thread dried-EDTA anticoagulant deposition was able to increase the wicking distance and has a better capability to separate blood plasma and is suitable for combining separation and the assay system in a single device.
  3. Nilghaz A, Wicaksono DH, Gustiono D, Abdul Majid FA, Supriyanto E, Abdul Kadir MR
    Lab Chip, 2012 Jan 7;12(1):209-18.
    PMID: 22089026 DOI: 10.1039/c1lc20764d
    This paper describes the fabrication of microfluidic cloth-based analytical devices (μCADs) using a simple wax patterning method on cotton cloth for performing colorimetric bioassays. Commercial cotton cloth fabric is proposed as a new inexpensive, lightweight, and flexible platform for fabricating two- (2D) and three-dimensional (3D) microfluidic systems. We demonstrated that the wicking property of the cotton microfluidic channel can be improved by scouring in soda ash (Na(2)CO(3)) solution which will remove the natural surface wax and expose the underlying texture of the cellulose fiber. After this treatment, we fabricated narrow hydrophilic channels with hydrophobic barriers made from patterned wax to define the 2D microfluidic devices. The designed pattern is carved on wax-impregnated paper, and subsequently transferred to attached cotton cloth by heat treatment. To further obtain 3D microfluidic devices having multiple layers of pattern, a single layer of wax patterned cloth can be folded along a predefined folding line and subsequently pressed using mechanical force. All the fabrication steps are simple and low cost since no special equipment is required. Diagnostic application of cloth-based devices is shown by the development of simple devices that wick and distribute microvolumes of simulated body fluids along the hydrophilic channels into reaction zones to react with analytical reagents. Colorimetric detection of bovine serum albumin (BSA) in artificial urine is carried out by direct visual observation of bromophenol blue (BPB) colour change in the reaction zones. Finally, we show the flexibility of the novel microfluidic platform by conducting a similar reaction in a bent pinned μCAD.
  4. Wicaksono DH, Syazwani IN, Ratnarathorn N, Sadir S, Shahir S, Ruckthong L, et al.
    Bioanalysis, 2019 May;11(9):855-873.
    PMID: 31084195 DOI: 10.4155/bio-2018-0190
    Aim: Time-based microfluidic absorption sampling was proposed using cotton fiber-based device made in swab stick. The assay was optimized and compared with conventional pipetted drop sampling using the same device. Materials & methods: Reagents were integrated into cotton fiber device for assessing concentration of analytes by the colorimetric detection method through time-based absorption sampling microfluidic system. All assay parameters were first optimized using conventional pipette-based drop sampling. Results: The color intensity is linear in the relevant concentration range of the analytes. The LOD are 0.189 mM for glucose and 6.56 μM for nitrite, respectively. These values are better than conventional drop sampling. The fiber-containing swab itself functions as sampling, assay and calibration device. Conclusion: Microfluidic cotton fiber-based assay device was fabricated and can determine analyte concentration in artificial salivary samples, colorimetrically, by time-based absorption sampling without the need of complex equipments.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links