Displaying all 4 publications

Abstract:
Sort:
  1. Makahleh A, Ben-Hander GM, Saad B
    Bioanalysis, 2015;7(6):713-23.
    PMID: 25871588 DOI: 10.4155/bio.14.307
    BACKGROUND: A simple and sensitive hollow fiber-liquid phase microextraction with in situ derivatization method was developed for the determination of α-ketoglutaric (α-KG) and pyruvic acids (PA) in small-volume urine samples. 2,4,6-trichloro phenyl hydrazine was used as derivatization agent.
    RESULTS: Under the optimum extraction conditions, enrichment factors of 742 and 400 for α-KG and PA, respectively, were achieved. Calibration curves were linear over the range 1 to 1000 ng/ml (r(2) ≥ 0.998). Detection and quantitation limits were 0.03 and 0.02, and 0.10 and 0.05 ng/ml for α-KG and PA, respectively.
    CONCLUSION: The concentrations in diabetic II and liver cancer samples were significantly lower than those from healthy people, showing their potential as biomarkers for these diseases.
  2. Lee PY, Osman J, Low TY, Jamal R
    Bioanalysis, 2019 Oct;11(19):1799-1812.
    PMID: 31617391 DOI: 10.4155/bio-2019-0145
    Plasma and serum are widely used for proteomics-based biomarker discovery. However, analysis of these biofluids is highly challenging due to the complexity and wide dynamic range of their proteomes. Notably, highly abundant proteins tend to obscure the detection of potential biomarkers that are usually of lower concentrations. Among the strategies to resolve this problem are: depletion of high-abundance proteins, enrichment of low abundant proteins of interest and prefractionation. In this review, we focus on current and emerging depletion techniques used to enhance the detection and identification of the less abundant proteins in plasma and serum. We discuss the applications and contributions of these methods to proteomics analysis of plasma and serum alongside their limitations and future perspectives.
  3. Wicaksono DH, Syazwani IN, Ratnarathorn N, Sadir S, Shahir S, Ruckthong L, et al.
    Bioanalysis, 2019 May;11(9):855-873.
    PMID: 31084195 DOI: 10.4155/bio-2018-0190
    Aim: Time-based microfluidic absorption sampling was proposed using cotton fiber-based device made in swab stick. The assay was optimized and compared with conventional pipetted drop sampling using the same device. Materials & methods: Reagents were integrated into cotton fiber device for assessing concentration of analytes by the colorimetric detection method through time-based absorption sampling microfluidic system. All assay parameters were first optimized using conventional pipette-based drop sampling. Results: The color intensity is linear in the relevant concentration range of the analytes. The LOD are 0.189 mM for glucose and 6.56 μM for nitrite, respectively. These values are better than conventional drop sampling. The fiber-containing swab itself functions as sampling, assay and calibration device. Conclusion: Microfluidic cotton fiber-based assay device was fabricated and can determine analyte concentration in artificial salivary samples, colorimetrically, by time-based absorption sampling without the need of complex equipments.
  4. Kit Loh GO, Ling Wong EY, Fung Tan YT, Lee YL, Chew CK, Mohd Sali ND, et al.
    Bioanalysis, 2021 Nov 08.
    PMID: 34743613 DOI: 10.4155/bio-2021-0185
    Aim: To develop an LC-MS/MS method for simultaneous determination of duloxetine and its metabolite, 4-hydroxy duloxetine glucuronide (4HDG) in human plasma and to investigate the potential back-conversion of 4HDG to duloxetine using stability study. Materials & methods: The LC-MS/MS method was validated according to the EMA and USFDA Bioanalytical Method Validation Guidelines and applied to pilot bioequivalence study. Results & conclusion: The method validation results were within the acceptance limits. The stability study and incurred sample reanalysis results ruled out the occurrence of back-conversion. The study highlighted the conduct of back-conversion test and the advantages of LC-MS/MS method in terms of sensitivity, specificity and low consumption of organic solvents.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links