Displaying all 8 publications

Abstract:
Sort:
  1. Yahaya SA, Ripin ZM, Ridzwan MIZ
    Osteoporos Int, 2020 Jan;31(1):43-58.
    PMID: 31446442 DOI: 10.1007/s00198-019-05128-x
    Various mechanical and biomechanical test systems to evaluate the effectiveness of hip protectors designed to prevent hip fracture as a result of falls were examined in this review. The articles considered were selected systematically. The effect of differences in design criteria was demonstrated, and it was observed that the impact energy employed during testing dramatically affects the performance of the hip protector. Over the past three decades, researchers have continuously experimented with various systems to determine the efficacy of various hip protectors. The primary aim has been to make informed decisions in optimizing hip protector design. This article provides a systematic review of various test systems employed in the determination of the biomechanical efficacy of hip protectors. A systematic literature search was carried out, and 28 relevant articles were included to demonstrate the effect of test systems in the evaluation of the biomechanical effectiveness of hip protectors. Methodological studies illustrated the appropriate use of impact testing systems for the simulation of hip anatomy and fall dynamics in evaluating the effectiveness of hip protectors in preventing a hip fracture. This systematic review has demonstrated the effect of the variability of test systems on the evaluation of impact attenuation by various hip protectors. The lack of standardized test systems accounts for the inconsistencies in the test results of the efficacy of hip protectors. This has been a major challenge in the efforts of researchers to optimize the interventions. The standardization of test systems may require needed improvements immediately as opposed to the development of new interventions in order to ensure that only hip protectors with adequately proven efficacies are deployed for clinical trials or for the protection of the hips of vulnerable individuals from sideways impact.
  2. Yahaya SA, Ripin ZM, Ridzwan MIZ
    3D Print Addit Manuf, 2023 Oct 01;10(5):971-983.
    PMID: 37886404 DOI: 10.1089/3dp.2021.0014
    Fused deposition modeling has provided a cheap and effective method for the rapid production of prototypes and functional products in many spheres of life. In this study, three-dimensional (3D) printing techniques to produce and optimize a hip protector that will assure clinical efficacy are presented. The I-Optimal design was used to optimize the hip protector's significant parameters (infill density, shell thickness, and material shore hardness) to obtain maximum femoral neck force attenuation of the 3D-printed hip protector. A drop impact tower device simulates the impact force at the hip's parasagittal plane during a fall. The results show that the infill density has the most significant influence on attenuation properties, followed by the infill density combined with the material shore hardness. By maximizing all the parameters, it is demonstrated that using an additive manufacturing technique to print hip protectors could be an effective strategy in curbing hip fractures.
  3. Roslan A, Tey YS, Ares F, Ashari A, Shaparudin A, Wan Rahimi WF, et al.
    Med J Malaysia, 2022 Nov;77(6):736-743.
    PMID: 36448393
    INTRODUCTION: Transcatheter aortic valve replacements (TAVRs) has become widespread throughout the world. To date, there are no echocardiographic studies of TAVR patients from Southeast Asia (SEA). We sought to evaluate (1) changes in echocardiographic and strain values pre- and post-TAVR (2) relationship between aortic stenosis (AS) severity and strain values, (3) left ventricle geometry in severe AS, (4) relationship of flow rate to dimensionless index (DVI) and acceleration time (AT), and (5) effect of strains on the outcome.

    MATERIALS AND METHODS: Retrospective study of 112 TAVR patients in our centre from 2009 to 2020. The echocardiographic and strain images pre (within 1 month), post (day after), and 6 months post-TAVR were analyzed by expert echocardiographer.

    RESULTS: The ejection fraction (EF) increased at 6 months (53.02 ± 12.12% to 56.35 ± 9.00%) (p=0.044). Interventricular septal thickness in diastole (IVSd) decreased (1.27 ± 0.21 cm to 1.21 ± 0.23 cm) (p=0.038) and left ventricle internal dimension in diastole (LVIDd) decreased from 4.77 ± 0.64 cm to 4.49 ± 0.65 cm (p=0.001). No changes in stroke volume index (SVI pre vs 6 months p=0.187), but the flow rate increases (217.80 ± 57.61 mls/s to 251.94 ± 69.59 mls/s, p<0.001). Global longitudinal strain (GLS) improved from -11.44 ± 4.23% to -13.94 ± 3.72% (p<0.001), left atrial reservoir strain (Lar-S) increased from 17.44 ± 9.16% to 19.60 ± 8.77% (p=0.033). Eight patients (7.5%) had IVSd < 1.0 cm, and 4 patients (3.7%) had normal left ventricle (LV) geometry. There was linear relationship between IVSd and mean PG (r=0.208, p=0.031), between GLS to aortic valve area (AVA) and aortic valve area index (AVAi) (r = - 0.305, p=0.001 and r= - 0.316, p= 0.001). There was also relationship between AT (r=-0.20, p=0.04) and DVI (r=0.35, p<0.001) with flow rate. Patients who died late (after 6 months) had lower GLS at 6 months. (Alive; -13.94 ± 3.72% vs Died; -12.43 ± 4.19%, p=0.001).

    CONCLUSION: At 6 months, TAVR cause reverse remodelling of the LV with the reduction in IVSd, LVIDd, and improvement in GLS and LAr-S. There is a linear relationship between GLS and AVA and between IVSd and AVA.

  4. Linn YL, Wang JC, Pua U, Yahaya SA, Choke ET, Chong TT, et al.
    Vascular, 2023 Aug;31(4):767-776.
    PMID: 35410542 DOI: 10.1177/17085381221081969
    BACKGROUND: Results from the BIOLUX P-III registry have demonstrated favourable outcomes of Passeo-18 Lux™ (Biotronik®, Buelach, Switzerland) drug-coated balloon in treating obstructive infrainguinal peripheral artery disease, but it has not been established if Asians would benefit to the same extent as non-Asians.

    METHODS: A subgroup analysis was performed on the 24-month data comparing the Asian cohort (AC) to non-Asian cohort (NAC).

    RESULTS: AC included 49 patients with 77 lesions. AC was significantly younger (65.6 vs 70.3 years, p < 0.05), had more diabetes (87.8% vs 45.3%, p < 0.05), and was more likely to present with CLTI (73.5% vs 35.3%, p < 0.001) compared to NAC. They had significantly longer mean target lesions (115 vs 86.9 mm, p = 0.006), and received significantly higher paclitaxel doses (10.7 vs 7.2 mg, p = 0.0005). Device, technical and procedural successes were 125/125(100%), 95/97(97.5%) and 45/49(91.8%), respectively. There was no significant difference in target lesion revascularization rates between groups (10.5% vs 12%, p = 0.91). However, the AC had more major adverse events (30.2% vs 16.1%, p = 0.001), amputations (26.3% vs 6.2%, p < 0.05) and mortality (37.9% vs 10.6%, p < 0.05) at 24 months.

    CONCLUSION: Passeo-18 Lux™ use was efficacious in Asians, but was associated with higher adverse events, amputations and mortality rates, likely attributable to poorer patient comorbidities and more extensive PAD.

  5. Fong SW, Few LL, See Too WC, Khoo BY, Nik Ibrahim NN, Yahaya SA, et al.
    BMC Res Notes, 2015;8:679.
    PMID: 26576922 DOI: 10.1186/s13104-015-1677-8
    Biomarkers play a pivotal role in the diagnosis and management of patients with acute coronary syndrome. This study aimed to investigate the differences in level of several biomarkers, i.e. C-reactive protein, myeloperoxidase, soluble CD40 ligand and placental growth factor, between acute coronary syndrome and chronic stable angina patients. The relationship between these biomarkers in the coronary circulation and systemic circulation was also investigated.
  6. Mwipatayi BP, Barry IP, Brodmann M, Zeller T, Varcoe RL, Moscovic M, et al.
    Ann Vasc Surg, 2021 Aug;75:237-252.
    PMID: 33831519 DOI: 10.1016/j.avsg.2021.02.050
    OBJECTIVES: This study aims to assess the use of drug-coated balloon (DCB) in a large patient population under real-world conditions and, specifically, analyse the impact of diabetes mellitus on long term outcomes following DCB utilisation.

    METHODS: BIOLUX P-III is a prospective, international, multicentre, registry that was conducted at 41 centres. The present study is a 24-month subgroup analysis of patients with diabetes mellitus having infrainguinal lesions treated with the Passeo-18 Lux DCB. The primary endpoints were freedom from major adverse events (MAEs) within 6 months of intervention and freedom from clinically driven target lesion revascularisation (CD-TLR) within 12 months of intervention.

    RESULTS: Of the 882 patients in the registry, 418 had diabetes (516 lesions). Most diabetics had concomitant hypertension (88.8%) and hyperlipidaemia (70.3%). Insulin dependence was observed in 48.8% of diabetics. Moreover, smoking (62.2%) and chronic renal insufficiency (41.9%) were also found to be common in this cohort. Chronic limb threatening ischemia (Rutherford class ≥4) was present in 53.1% of all patients. 22.9% of lesions were infrapopliteal, while 22.5% of lesions were treated for in-stent restenosis. The mean target lesion length was 85.6 ± 73.2 mm, and 79.4% of lesions were calcified (of which 17.9% were heavily calcified). Overall, device success was 99.7%. Freedom from MAEs was 90.5% (95% confidence interval (95% CI): 87.2-93.0) at 6 months, 85.4% (95% CI: 81.5-88.6) at 12 months and 80% (95% CI: 75.5-83.8) at 24 months. Freedom from CD-TLR was 95.9% (95% CI: 93.8-97.4), 91.6% (95% CI: 88.7-93.8), and 87.1% (95% CI: 83.5-89.9) at 6, 12, and 24 months, respectively. All-cause mortality at 24 months in diabetics was 16.0% (95% CI: 12.6-20.2), and major target limb amputation was 6.1% (95% CI: 4.1-8.9), which was significantly higher than in non-diabetics (8.4% (95% CI: 6.0-11.6), P = 0.0005 and 1.2% (95% CI: 0.5-2.9), P <0.0001, respectively). At 24 months, 82.0% of patients had improved by ≥1 Rutherford class.

    CONCLUSION: Treatment of a real-world diabetic patient population with the Passeo-18 Lux DCB resulted in high efficacy and low complication rates, despite the fact that diabetic patients usually suffer from a multitude of concomitant comorbidities.

    CLINICAL TRIAL REGISTRATION: NCT02276313.

  7. Roslan A, Soon CK, Sin TY, Aktifanus ATJ, Ling SS, Boon WK, et al.
    J Cardiothorac Surg, 2024 Jan 02;19(1):3.
    PMID: 38167451 DOI: 10.1186/s13019-023-02472-2
    BACKGROUND: This study examined the characteristics and outcomes of surgical aortic valve replacement (SAVR) both isolated and in combination with other cardiac surgery in Malaysia from 2015 to 2021.

    METHODS: This was a retrospective study of 1346 patients analyzed on the basis of medical records, echocardiograms and surgical reports. The overall sample was both considered as a whole and divided into aortic stenosis (AS)/aortic regurgitation (AR)-predominant and similar-severity subgroups.

    RESULTS: The most common diagnosis was severe AS (34.6%), with the 3 most common etiologies being bicuspid valve degeneration (45.3%), trileaflet valve degeneration (36.3%) and rheumatic valve disease (12.2%). The second most common diagnosis was severe AR (25.5%), with the most common etiologies being root dilatation (21.0%), infective endocarditis (IE) (16.6%) and fused prolapse (12.2%). Rheumatic valve disease was the most common mixed disease. A total of 54.5% had AS-predominant pathology (3 most common etiologies: bicuspid valve degeneration valve, degenerative trileaflet valve and rheumatic valve disease), 36.9% had AR-predominant pathology (top etiologies: root dilatation, rheumatic valve disease and IE), and 8.6% had similar severity of AS and AR. Overall, 62.9% of patients had trileaflet valve morphology, 33.3% bicuspid, 0.6% unicuspid and 0.3% quadricuspid. For AS, the majority were high-gradient severe AS (49.9%), followed by normal-flow low-gradient (LG) severe AS (10.0%), paradoxical low-flow (LF)-LG severe AS (6.4%) and classical LF-LG severe AS (6.1%). The overall in-hospital and total 1-year mortality rates were 6.4% and 14.8%, respectively. Pure severe AS had the highest mortality. For AS-predominant pathology, the etiology with the highest mortality was trileaflet valve degeneration; for AR-predominant pathology, it was dissection. The overall survival probability at 5 years was 79.5% in all patients, 75.7% in the AS-predominant subgroup, 83.3% in the AR-predominant subgroup, and 87.3% in the similar-severity subgroup.

    CONCLUSIONS: The 3 most common causes of AS- predominant patients undergoing SAVR is bicuspid valve degeneration, degenerative trileaflet valve and rheumatic and for AR-predominant is root dilatation, rheumatic and IE. Rheumatic valve disease is an important etiology in our SAVR patients especially in mixed aortic valve disease. Study registration IJNREC/562/2022.

  8. Chiam PTL, Hayashida K, Watanabe Y, Yin WH, Kao HL, Lee MKY, et al.
    Open Heart, 2021 01;8(1).
    PMID: 33419935 DOI: 10.1136/openhrt-2020-001541
    OBJECTIVES: Transcatheter aortic valve replacement (TAVR) is increasingly performed. Physically small Asians have smaller aortic root and peripheral vessel anatomy. The influence of gender of Asian patients undergoing TAVR is unknown and may affect outcomes. The aim of this study was to assess sex differences in Asian patients undergoing TAVR.

    METHODS: Patients undergoing TAVR from eight countries were enrolled. In this retrospective analysis, we examined differences in characteristics, 30-day clinical outcomes and 1-year survival between female and male Asian patients.

    RESULTS: Eight hundred and seventy-three patients (54.4% women) were included. Women were older, smaller and had less coronary artery and lung disease but tended to have higher logistic EuroSCOREs. Smaller prostheses were used more often in women. Major vascular complications occurred more frequently in women (5.5% vs 1.8%, p<0.01); however, 30-day stroke and mortality (women vs men: 1.5% vs 1.6%, p=0.95% and 4.3% vs 3.4%, p=0.48) were similar. Functional status improvement was significant and comparable between the sexes. Conduction disturbance and permanent pacemaker requirements (11.2% vs 9.0%, p=0.52) were also similar as was 1-year survival (women vs men: 85.6% vs 88.2%, p=0.25). The only predictors of 30-day mortality were major vascular injury in women and age in men.

    CONCLUSIONS: Asian women had significantly smaller stature and anatomy with some differences in clinical profiles. Despite more frequent major vascular complications, women had similar 30-day stroke or mortality rates. Functional status improvement was significant and comparable between the sexes. Conduction disturbance and permanent pacemaker requirements were similar as was 1-year survival.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links