Gloves that will provide a barrier of protection from infectious organisms are an essential feature of medical practice for the protection of both patients and medical personnel. Natural rubber latex has consistently been the most satisfactory raw material for the manufacture of gloves. Certain latex proteins, carried over into the finished product by inadequate manufacturing processes, may pose a risk of provoking allergic reactions in some patients and medical workers. As with any allergy, the risk depends on the route of exposure and dose. Hence, the method of manufacture, including the means used to coat gloves to make donning easy, can influence the eventual exposure of sensitive people to latex allergens. In this article, we describe the several processes in use and their effects on latex protein content.
Health care workers have been reported to constitute one of the few high-risk groups related to IgE-mediated hypersensitivity associated with the use of latex products. This paper describes the first ever study of prevalence carried out in Malaysia among these workers. One hundred and thirty health care personnel from Hospital Kuala Lumpur were skin tested. Extracts used were prepared from seven different brands of natural rubber latex gloves with varying levels of extractable protein (EPRRIM). Out of the 130 volunteers, 4 (3.1%) had positive skin test to latex with extracts with high levels of EPRRIM (> 0.7 mg/g). The prevalence among the Malaysian health care workers can be considered to be low in comparison to that of some consumer countries as the USA which reported a prevalence of as high as 16.9%.