Displaying all 2 publications

Abstract:
Sort:
  1. Rogers BD, Rengarajan A, Abrahao L, Bhatia S, Bor S, Carlson DA, et al.
    Neurogastroenterol Motil, 2021 06;33(6):e14009.
    PMID: 33094875 DOI: 10.1111/nmo.14009
    BACKGROUND: Esophagogastric junction contractile integral (EGJ-CI) and EGJ morphology are high-resolution manometry (HRM) metrics that assess EGJ barrier function. Normative data standardized across world regions and HRM manufacturers are limited.

    METHODS: Our aim was to determine normative EGJ metrics in a large international cohort of healthy volunteers undergoing HRM (Medtronic, Laborie, and Diversatek software) acquired from 16 countries in four world regions. EGJ-CI was calculated by the same two investigators using a distal contractile integral-like measurement across the EGJ for three respiratory cycles and corrected for respiration (mm Hg cm), using manufacturer-specific software tools. EGJ morphology was designated according to Chicago Classification v3.0. Median EGJ-CI values were calculated across age, genders, HRM systems, and regions.

    RESULTS: Of 484 studies (28.0 years, 56.2% F, 60.7% Medtronic studies, 26.0% Laborie, and 13.2% Diversatek), EGJ morphology was type 1 in 97.1%. Median EGJ-CI was similar between Medtronic (37.0 mm Hg cm, IQR 23.6-53.7 mm Hg cm) and Diversatek (34.9 mm Hg cm, IQR 22.1-56.1 mm Hg cm, P = 0.87), but was significantly higher using Laborie equipment (56.5 mm Hg cm, IQR 35.0-75.3 mm Hg cm, P 

  2. Sifrim D, Roman S, Savarino E, Bor S, Bredenoord AJ, Castell D, et al.
    Gut, 2020 Oct 09.
    PMID: 33037054 DOI: 10.1136/gutjnl-2020-322627
    OBJECTIVE: Limitations of existing impedance-pH thresholds include small sample size of normative studies, inclusion of artefactual pH drops and incorrect identification of impedance reflux events. We aimed to obtain new impedance-pH thresholds from expert consensus analysis of tracings from a large number of healthy subjects.

    DESIGN: Of 541 studies performed worldwide using two different systems (Diversatek, USA, and Laborie, Netherlands), 150 tracings with oesophageal diagnoses, behavioural disorders and study-related artefacts were excluded. The remainder studies were subject to two reviewer consensus analysis, in-person or through video conference, consisting of editing meals and pH drops, identification of impedance reflux and postreflux swallow-induced peristaltic wave (PSPW) using strict pre-established criteria and measurement of distal mean nocturnal baseline impedance (MNBI).

    RESULTS: Consensus analysis was performed in 391 tracings (age 32.7 years, range 18-71, 54.2% female). Normative thresholds were significantly different between Diversatek and Laborie (total acid exposure time: 2.8% and 5%; reflux episodes: 55 and 78; MNBI at 3 cm: 1400 and 1500 ohms, at 5 cm: 1400 and 1800 ohms). Males had higher acid exposure, more reflux episodes and lower MNBI. Significant regional differences were identified, including higher PSPW scores in Western countries, and higher MNBI in Asia using Diversatek, and higher acid exposure in the Netherlands, higher MNBI in Asia and South Africa, and lower MNBI in Turkey using Laborie.

    CONCLUSION: Normal impedance-pH monitoring thresholds have regional and system-related differences. Clinical interpretation needs to use normal thresholds valid for the system used and world region, following careful editing of the tracings.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links