Displaying all 3 publications

Abstract:
Sort:
  1. Ahmad H, Latif AA, Abdul Khudus MI, Zulkifli AZ, Zulkifli MZ, Thambiratnam K, et al.
    Appl Opt, 2013 Feb 1;52(4):818-23.
    PMID: 23385923 DOI: 10.1364/AO.52.000818
    A highly stable tunable dual-wavelength fiber laser (TDWFL) using graphene as a means to generate a highly stable output is proposed and generated. The TDWFL comprises a 1 m long, highly doped erbium-doped fiber (EDF) acting as the linear gain medium, with a 24-channel arrayed waveguide grating acting as a wavelength slicer as well as a tuning mechanism to generate different wavelength pairs. The tuned wavelength pairs can range from 0.8 to 18.2 nm. A few layers of graphene are incorporated into the laser cavity to induce the four-wave-mixing effect, which stabilizes the dual-wavelength output by suppressing the mode competition that arises as a result of homogenous broadening in the EDF.
  2. Isa MFM, Ghazi FN, Merican SRHI, Zulkifli AZ, Singh P
    Prague Med Rep, 2024;125(3):273-278.
    PMID: 39171554 DOI: 10.14712/23362936.2024.25
    Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV2) caused imminent acute infection of respiratory tract known as Coronavirus disease 2019 (COVID-19). Complications of hepatobiliary system especially liver often found in post-acute COVID-19 patients. However, there are only few studies specifically discussing about liver abscess in patients who had history of contracted COVID-19. We present a case of a 54-years-old gentleman with no previous medical illness and no history of vaccination, who was presented with ruptured liver abscess post COVID-19 infection Category 4 (symptomatic with lung infection and the need of oxygen supplementation). Percutaneous drainage was performed to drain the abscess and collections.
  3. Ahmad H, Thambiratnam K, Zulkifli AZ, Lawrence A, Jasim AA, Kunasekaran W, et al.
    Sensors (Basel), 2013 Sep 30;13(10):13276-88.
    PMID: 24084118 DOI: 10.3390/s131013276
    An efficient and low cost optical method for directly measuring the concentration of homogenous biological solutes is proposed and demonstrated. The proposed system operates by Fresnel reflection, with a flat-cleaved single-mode fiber serving as the sensor probe. A laser provides a 12.9 dBm sensor signal at 1,550 nm, while a computer-controlled optical power meter measures the power of the signal returned by the probe. Three different mesenchymal stem cell (MSC) lines were obtained, sub-cultured and trypsinized daily over 9 days. Counts were measured using a haemocytometer and the conditioned media (CM) was collected daily and stored at -80 °C. MSCs release excretory biomolecules proportional to their growth rate into the CM, which changes the refractive index of the latter. The sensor is capable of detecting changes in the number of stem cells via correlation to the change in the refractive index of the CM, with the measured power loss decreasing approximately 0.4 dB in the CM sample per average 1,000 cells in the MSC subculture. The proposed system is highly cost-effective, simple to deploy, operate, and maintain, is non-destructive, and allows reliable real-time measurement of various stem cell proliferation parameters.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links