METHODS: Patients aged 18 years old or above and who were scheduled for gynecology surgery were selected. Three different models with a combination of latent factors were based on a priori hypotheses from previous studies. The root-mean-squared error of approximation, comparative fit index, Tucker-Lewis Index, Chi-squared test, and change in Chi-squared statistic given a change in degrees of freedom between models were used to assess the model fit to the present data.
RESULTS: A total of 302 patients completed the questionnaire. The five-factor model which was based on Gordon's study has an acceptable fit for the data and was superior when compared to the one-factor baseline model. Although the four-factor model, which originated from Botti's study, also demonstrates a good model fit, the "perception of care" construct was excluded in this model. The "perception of care" construct is conceptually important as patient-centered care has become the focus of quality improvement of pain service.
CONCLUSIONS: The APS-POQ-R is easy to administer and is useful for quality evaluation in postoperative pain management. The present study demonstrates that a five-factor structure of the APS-POQ-R is the best fitting model in our patient sample. The results of this study provide further evidence to support the use of APS-POQ-R as a measurement tool for pain management evaluation in acute postoperative patients with a multi-cultural background.
METHODS: We evaluated the performance characteristics of the LMA Protector™ in 30 unparalysed, moderately obese patients. First attempt insertion rate, time for insertion, oropharyngeal leak pressure (OLP), and incidence of complications were recorded.
RESULTS: We found high first and second attempt insertion rates of 28(93%) and 1(33%) respectively, with one failed attempt where no capnography trace could be detected, presumably from a downfolded device tip. The LMA Protector™ was inserted rapidly in 21.0(4.0) seconds and demonstrated high OLP of 31.8(5.4) cmH2O. Fibreoptic assessment showed a clear view of vocal cords in 93%. The incidence of blood staining on removal of device was 48%, postoperative sore throat 27%, dysphagia 10% and dysphonia 20% (all self-limiting, resolving a few hours postoperatively).
CONCLUSIONS: We conclude that the LMA Protector™ was associated with easy, expedient first attempt insertion success, demonstrating high oropharyngeal pressures and good anatomical position in the moderately obese population, with relatively low postoperative airway morbidity.
TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry, ACTRN12617001152314 . Registered 7 August 2017.
CASE PRESENTATION: In a 65-year old male undergoing the bicuspid aortic valve (BAV) repair and the extensive remodeling of dilated sinus and tubular junction, and preoperative coronary angiography were unsuccessfully completed due to an allergic reaction to the contrast medium. Intraoperative TEE by employing various 3-dimensional volume images of coronary ostia and Doppler tracings of the coronary arterial flows enabled a thorough pre-procedural evaluation of the high take-off coronary arteries and post-procedural evaluation by confirming the absence of any compromise in coronary arterial flow.
CONCLUSION: In the present case, intraoperative application of various TEE imaging modalities enabled comprehensive evaluation of high-taking off coronary artery, as an alternative to preoperative coronary angiography, in a patient undergoing an extensive aortic valve and aortic root repair procedure.
METHODS: Thirty six patients with head injury admitted to neurosurgical ICU in University Malaya Medical Centre were recruited for this study, over a 6-month period from July 2014 to January 2015. Patients were randomized to receive either an immunonutrition (Group A) or a standard (Group B) enteral feed. Levels of biomarkers were measured at day 1, 5 and 7 of enteral feeding.
RESULTS: Patients in Group A showed significant reduction of IL-6 at day 5 (p
METHODS: A 40-question anonymous online questionnaire was distributed to anesthesiologists and anesthesia trainees in six countries in the Asia-Pacific (Singapore, Malaysia, Philippines, Thailand, India and South Korea). Participants were polled about their current practices in patient warming and temperature measurement across the preoperative, intraoperative and postoperative periods. Questions were also asked regarding various individual and environmental barriers to compliance.
RESULTS: In total, 1154 valid survey responses were obtained and analyzed. 279 (24.2%) of respondents prewarm, 508 (44.0%) perform intraoperative active warming, and 486 (42.1%) perform postoperative active warming in the majority of patients. Additionally, 531 (46.0%) measure temperature preoperatively, 767 (67.5%) measure temperature intraoperatively during general anesthesia, and 953 (82.6%) measure temperature postoperatively in the majority of patients. The availability of active warming devices in the operating room (p
METHODS: A hundred and twenty ASA 1-3 adults were randomly reversed with 1 mg/kg sugammadex prior to extubation followed by another 1 mg/kg immediately after extubation (staggered group), single dose of 2 mg/kg sugammadex (single bolus group) or neostigmine 0.02 mg/kg with glycopyrrolate (neostigmine group).
RESULTS: We found 70% of patients (n = 28) reversed with single boluses of sugammadex had Grade 3 emergence cough compared to 12.5% (n = 5) in the staggered sugammadex group and 17.5% (n = 7) in the neostigmine group (p
METHODS: Sixty patients were randomised to receive IV dexmedetomidine 0.5 μg.kg-1 (Group DEX, n = 30) or IV saline (Group P, n = 30). General anaesthesia was maintained with Sevoflurane: oxygen: air, titrated to BIS 40-60. Pain intensity, sedation, rescue analgesics, nausea/vomiting and resumption of daily activities were recorded at 1 h, and postoperative day (POD) 1-5.
RESULTS: Group DEX patients had significant reduction in sevoflurane minimum alveolar concentration (MAC), mean (SD) DEX vs. Placebo 0.6 (0.2) vs. 0.9 (0.1), p = 0.037; reduced postoperative resting pain at 1 h (VAS 0-10) (mean (SD) 1.00 (1.84) vs. 2.63 (2.78), p = 0.004), POD 1 (mean (SD) 1.50 (1.48) vs. 2.87 (2.72), p = 0.002), POD 2 (0.53 (0.97) vs. 1.73 (1.96), p = 0.001) and POD 3 (0.30 (0.75) vs. 0.89 (1.49), p = 0.001). DEX patients also had less pain on movement POD 1 (3.00 (2.12) vs. 4.30 (3.10), p = 0.043) and POD 2 (2.10 (1.98) vs. 3.10 (2.46), p = 0.040), with higher resumption of daily activities by 48 h compared to placebo, 87% vs. 63%, p = 0.04.
CONCLUSIONS: We conclude that a single dose of dexmedetomidine was a useful adjuvant in reducing MAC and postoperative pain (at 1 h and POD 1-3), facilitating faster return to daily activities by 48 h.
TRIAL REGISTRATION: The Australian New Zealand Clinical Trials Registry (ANZCTR), ACTRN12617001120369 , 31st July 2017, retrospectively registered.
METHODS: Ninety-seven patients with adolescent idiopathic scoliosis (AIS) who underwent posterior spinal fusion surgery at a single tertiary institution from March 2019 until June 2020 were enrolled in this retrospective study. Anesthesia was maintained using a target-controlled infusion of remifentanil combined with volatile anesthetic desflurane in 92 patients, while five patients received it as part of total intravenous anesthesia. Intravenous ketamine, paracetamol, and fentanyl were administered as multimodal analgesia. All patients received patient-controlled analgesia (PCA) morphine postoperatively. Pain scores at rest and on movement, assessed using the numerical rating scale, and the cumulative PCA morphine consumption were collected at a six-hourly interval for up to 48 h. According to the median intraoperative remifentanil dose usage of 0.215 µg/kg/min, patients were divided into two groups: low dose and high dose group.
RESULTS: There were no significant differences in the pain score and cumulative PCA morphine consumption between the low and high dose remifentanil group. The mean duration of remifentanil infusion was 134.9 ± 22.0 and 123.4 ± 23.7 min, respectively.
CONCLUSION: Intraoperative use of remifentanil as an adjuvant in AIS patients undergoing posterior spinal fusion surgery was not associated with postoperative hyperalgesia.
CASE PRESENTATION: A 37 year old Malaysian Chinese parturient was admitted at 25 weeks gestation following a scan which suggested intrauterine death and placenta accreta. She was diagnosed to have congenital complete heart block after her first delivery eight years previously but a pacemaker was never inserted. These medical conditions make her extremely likely to experience massive bleeding and haemodynamic instability. Among the measures taken to optimise her pre-operatively were the insertion of a temporary intravenous pacemaker and embolization of the uterine arteries to minimize peri-operative blood loss. She successfully underwent surgery under general anesthesia, which was relatively uneventful and was discharged well on the fourth post-operative day.
CONCLUSION: Congenital heart block in pregnancies in the presence of potential massive bleeding is best managed by a team, with meticulous pre-operative optimization. Suggested strategies would include insertion of a temporary pacemaker and embolization of the uterine arteries to reduce the risk of the patient getting into life threatening situations.