Displaying all 2 publications

Abstract:
Sort:
  1. Mat Bah MN, Sapian MH, Jamil MT, Abdullah N, Alias EY, Zahari N
    Congenit Heart Dis, 2018 Nov;13(6):1012-1027.
    PMID: 30289622 DOI: 10.1111/chd.12672
    OBJECTIVES: There is limited data on congenital heart disease (CHD) from the lower- and middle-income country. We aim to study the epidemiology of CHD with the specific objective to estimate the birth prevalence, severity, and its trend over time.

    DESIGN: A population-based study with data retrieved from the Pediatric Cardiology Clinical Information System, a clinical registry of acquired and congenital heart disease for children.

    SETTING: State of Johor, Malaysia.

    PATIENTS: All children (0-12 years of age) born in the state of Johor between January 2006 and December 2015.

    INTERVENTION: None.

    OUTCOME MEASURE: The birth prevalence, severity, and temporal trend over time.

    RESULTS: There were 531,904 live births during the study period with 3557 new cases of CHD detected. Therefore, the birth prevalence of CHD was 6.7 per 1000 live births (LB) (95% confidence interval [CI]: 6.5-6.9). Of these, 38% were severe, 15% moderate, and 47% mild lesions. Hence, the birth prevalence of mild, moderate, and severe CHD was 3.2 (95% CI: 3.0-3.3), 0.9 (95% CI: 0.9- 1.1), and 2.6 (95% CI: 2.4-2.7) per 1000 LB, respectively. There was a significant increase in the birth prevalence of CHD, from 5.1/1000 LB in 2006 to 7.8/1000 LB in 2015 (P 
  2. Zanjani KS, Wong AR, Sadiq M, Weber HS, Cutler NG
    Congenit Heart Dis, 2010 Sep-Oct;5(5):439-43.
    PMID: 21087429 DOI: 10.1111/j.1747-0803.2010.00448.x
    Objectives: There is little evidence in the medical literature about safety of PDA device closure and its effects on aortic root diameter in Marfan patients. We reported on nine Marfan patients whose ducts were occluded by coil or Amplatzer Duct Occluder.
    Patients and interventions: Two patients had aneurismal type E ducts which were closed by a single coil, respectively. The others had conical ducts for which even Amplatzer occluder, stiff, or double coils were used.
    Results: No untoward consequence was found during a median follow up period of 18.5 months (range 3 months to 6.33 years). Two patients had small residual shunts. The observed change in the mean ratio of aortic root diameter to its estimated value was statistically insignificant in seven patients who had complete data on their aortic root diameter before PDA closure and during the follow up.
    Conclusions: We concluded that PDA device closure in Marfan patients is safe. Risk of residual shunt is higher even after closure of small ducts.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links