AIMS: To evaluate the prevalence of DF in children residing in Salem and also to find any correlation between DF and other related factors.
MATERIALS AND METHODS: One school from each block of Salem (total 21 blocks) was selected for the study. A single examiner had evaluated untreated caries, lesions, and DF (for permanent anterior teeth and molars) using the Dean's fluorosis index, in all children. Water fluoride level determination at each school was done using the Tamil Nadu Water Fluoridation and Drainage Board field kit. Other factors that may have contributed to DF were assessed using a questionnaire, which was provided to each student. The data obtained were statistically analyzed using the SPSS software version 11.5.
STATISTICAL ANALYSIS: Chi-square test was used for statistical analysis.
RESULTS: DF was present in 56.9% of the children examined. It was mostly seen in 9 years old (72%) and male (59%) children. A positive correlation was found between the occurrence of DF and the duration of residence in a place with high water fluoride content, consumption of borewell water (64%), the parts per million of fluoride in drinking water, consumption of black tea (59%). However, no correlation was found between DF, dental caries, consumption of milk, or consumption of foods cooked in aluminum vessels.
CONCLUSION: There was a correlation between DF and factors such as male gender, bore well water consumption, black tea consumption and the duration of residence in a place with high water fluoride content.
Methods: One hundred and eighty standardized disc samples were prepared, of which ninety samples each were used for surface roughness and microhardness test, respectively. They were divided equally into: Group 1 (Filtek-Z350-XT), Group 2 (Zmack-Comp), and Group 3 (Zr-Hybrid). For surface roughness test, all samples were polished with aluminium oxide discs and further subdivided into aged and unaged subgroups, in which composite samples in aged subgroups were subjected to 2500 thermal cycles. Next, all the samples were subjected to surface roughness test using a contact stylus profilometer. As for microhardness test, all the aged and unaged samples were tested using a Vickers hardness machine with a load of 300 kgf for 10 s and viewed under a digital microscope to obtain microhardness value. Data were analyzed using two-way ANOVA followed by post hoc Tukey's honestly significant difference and paired sample t-test with significance level set at P = 0.05.
Results: In both the aged and unaged groups, Zr-Hybrid showed statistically significantly lower surface roughness (P < 0.05) than Filtek-Z350-XT and Zmack-Comp, but no statistically significant difference was noted between Filtek-Z350-XT and Zmack-Comp (P > 0.05). A similar pattern was noted in microhardness test, whereby Zr-Hybrid showed the highest value (P < 0.05) followed by Filtek-Z350-XT and lastly Zmack-Comp. Besides, significant differences in surface roughness and microhardness were noted between the aged and unaged groups.
Conclusion: Zr-Hybrid seems to demonstrate better surface roughness and microhardness value before and after artificial ageing.
Aims: This study aims to evaluate and compare the bond strength and load deflection rate (LDR) of three different fixed retainer wires.
Materials and Methods: The wires were divided into three Groups: A - three-stranded twisted ligature wire, B - Bond-A-Braid (Reliance Orthodontics), and C - three-stranded twisted lingual retainer wire (3M Unitek). Twenty models were prepared for each group with a passive 15 mm long lingual retainer wire bonded to two lower incisors. An occlusogingival force was applied to the wire until it debonded. For LDR, three-point bending test was done at 0.5 mm deflection. These forces were measured using a Universal Instron Testing Machine.
Statistical Analysis: Mean bond strength/LDR and pairwise comparisons were analyzed with one-way ANOVA and Tukey's honest significant differencepost hoctest, respectively.
Results: Group C exhibited the highest mean bond strength and LDR of 101.17N and 1.84N, respectively. The intergroup comparisons were all statistically significant.
Conclusion: Compared to the other two wire types, Group C might be better retained on the teeth due to its higher bond strength. With its relatively higher LDR value, it may resist deformation from occlusal forces, thereby reducing inadvertent tooth movement and yet remain flexible enough to allow physiologic tooth movements.
AIM: The aim of this article is to study the common radiographic features of rhinomaxillary mucormycosis (RMM), find diagnostic criteria, and grade the disease according to the radiographic features.
SETTINGS: This study was conducted at Face Three-Dimensional Cone-Beam Computed Tomography (CBCT) Center, Aurangabad, Maharashtra.
MATERIALS AND METHODS: CBCT scans of 30 patients who were referred for CBCT scanning of suspected RMM were retrospectively evaluated for relevant radiological data.
RESULTS: The most common CBCT features of RMM were osteolytic lesions in alveolar bone, palate, nose and nasal cavity, and zygoma along with involvement of paranasal sinuses. About 76.66% of patients had a history of COVID-19 infection.
CONCLUSION: According to the collected data, the scans of probable rhinomaxillary mucormycosis were graded in three groups - mild, moderate, and severe. The goal of this article is to emphasize the most overlook diagnostic entity - CBCT and its significant importance in early diagnosis, treatment, and prognosis of RMM. Early diagnosis of RMM can save the patients from the extent of morbidity and mortality.
SUBJECT AND METHODS: The antimicrobial activities were determined using disc diffusion, minimum inhibitory concentration (MIC) and minimum fungicidal concentration (MFC). After incorporation into tissue conditioner, the color difference and surface roughness were evaluated after one day. The surface morphology and the antibiofilm activity were assessed on day 1 and day 14.
RESULTS: The zone of inhibition of OBEO on Sabouraud Dextrose agar was significantly wider than nystatin and deionized water (P=0.000) with the MIC and MFC values were 1.25% and 5%. Both OBEO concentrations incorporated into tissue conditioner, there was no significant difference of color changes in the light-dark character (P=0.102) and surface roughness (P=0.920) when compared to the control group. As for adherence at days 1 and 14, both concentrations of OBEO in tissue conditioner show significantly reduced adherence of C. albicans compared to the control group (P=0.000).
CONCLUSION: OBEO exhibited significantly better antifungal activity against C. albicans when compared to nystatin and deionized water and resulted in no significant color changes, better surface roughness and lesser adherence of C. albicans toward the tissue conditioner.
AIMS: This study aims to evaluate and compare the cytotoxicity and cell attachment properties of cGIC and nano-HA-silica-GIC on dental pulp stem cells (DPSCs).
METHODS AND MATERIALS: Material extracts of nano-HA-silica-GIC and cGIC were prepared into seven serial dilutions and applied to 96 well plates seeded with DPSCs. After 72 h, the cell viability was determined using MTT assay. The DPSCs cell attachment properties were examined under scanning electron microscope (SEM) after 24 and 72 h. Kruskal-Wallis test was used to analyse the data for MTT assay (P < 0.05). SEM images of cell attachment properties were also described.
RESULTS: Nano-HA-silica-GIC and cGIC was shown to be slight to non-cytotoxic at all concentrations, except 200 mg/ml. Moderate cytotoxicity has been observed at 200 mg/ml concentration where nano-HA-silica-GIC and cGIC revealed cell viability values of 44.38 and 42.15%, respectively. Nano-HA-silica-GIC demonstrated better cell viability values than cGIC at all concentrations except for 6.25 and 12.5 mg/ml. Nevertheless, the results were not statistically significant (P > 0.05). SEM examination revealed the increasing numbers of DPSCs attached to both groups with prominent filopodia, especially after 72 h.
CONCLUSIONS: Nano-HA-silica-GIC exhibited good biocompatibility which is comparable to cGIC and favoured the attachment of DPSCs.