Abstract:
Sort:
  1. Wahab RM, Idris H, Yacob H, Ariffin SH
    Eur J Orthod, 2012 Apr;34(2):176-81.
    PMID: 21478298 DOI: 10.1093/ejo/cjq179
    This prospective study investigated the difference in clinical efficiency between Damon™ 3 self-ligating brackets (SLB) compared with Mini Diamond conventional ligating brackets (CLBs) during tooth alignment in straightwire fixed appliance therapy. Twenty-nine patients (10 males and 19 females), aged between 14 and 30 years, were randomly divided into two groups: 14 patients received the SLB and 15 received the CLB. Upper arch impressions were taken for pre-treatment records (T(0)). A transpalatal arch was soldered to both maxillary first molar bands prior to extraction of the maxillary first premolars, followed by straightwire fixed appliances (0.022 × 0.028 inch). A 0.014 inch nickel titanium (NiTi) wire was used as the levelling and aligning archwire. Four monthly reviews were undertaken and impressions of the upper arch were taken at each appointment (T(1), T(2), T(3), and T(4)). Displacements of the teeth were determined using Little's irregularity index (LII). Data were analysed using the Mann-Whitney U-test. In the aligning stage, the CLB group showed significantly faster alignment of the teeth compared with the SLB group at the T(1)-T(2) interval (P < 0.05). However, there were no differences at T(2)-T(3), and T(3)-T(4) for either group (P > 0.05). The CLB group showed 98 per cent crowding alleviation compared with 67 per cent for the SLB after 4 months of alignment and levelling. Mini Diamond brackets aligned the teeth faster than Damon™ 3 but only during the first month. There was no difference in efficacy between the two groups in the later 3 weeks. Alleviation of crowding was faster with CLB than with SLB.
  2. Toman HA, Nasir A, Hassan R, Hassan R
    Eur J Orthod, 2011 Dec;33(6):700-4.
    PMID: 21282284 DOI: 10.1093/ejo/cjq147
    Thalassaemia is a public health problem in Malaysia. It is known to cause skeletal deformity. The purpose of this study was to compare the skeletal, dentoalveolar, and soft tissue features of Malay transfusion-dependent thalassaemia (TDT) patients with a Malay control group. Lateral cephalometric radiographs of 30 Malay (14 males and 16 females aged 6.4-21.8 years) TDT patients and 60 normal Malays matched for chronological age and gender were analysed and compared using an independent t-test. The TDT group showed a similar sagittal relationship to the control group but with a significantly increased (P < 0.01) mandibular plane inclination. They also showed a significantly shorter (P ≤ 0.001) mandibular body, ramus length, and posterior face height and consequently a smaller ratio of posterior to anterior face height (P < 0.01). The upper and lower lips were significantly procumbent (P < 0.001) in the TDT group together with a significantly smaller nasolabial angle (P < 0.05). Dentoalveolar measurements showed less proclined maxillary teeth in the TDT group compared with the controls (P < 0.05). The cephalometric features of Malay TDT patients were characterized by a mild Class II skeletal pattern, prominent vertical growth direction of the mandible, and protruded upper and lower lips.
  3. Albajalan OB, Samsudin AR, Hassan R
    Eur J Orthod, 2011 Oct;33(5):509-14.
    PMID: 21118908 DOI: 10.1093/ejo/cjq108
    The aim of this study was to compare the skeletal and soft tissue patterns between obstructive sleep apnoea (OSA) patients and control group of non-OSA patients. Fifty Malays (32 males and 18 females) aged 18-65 years divided into two equal groups 25 (17 males and 8 females) with OSA and a control group 25 subjects (15 males and 10 females). Both groups were diagnosed using polysomnography. Nineteen variables related to craniofacial skeletal and soft tissue morphology were measured on lateral cephalometric films. Analysis of covariance was used to compare the means between the two groups. The results showed that OSA subjects had a significant increase in body mass index (BMI) and neck circumference than the control group. The soft palate and tongue were longer and thicker in OSA patients. In addition, upper, middle, and lower posterior airway spaces were narrower, the hyoid bone was more inferior and posterior, and the cranial base flexure angle was significantly acute when compared with the control group. The findings indicate that craniofacial abnormalities play significant roles in the pathogenesis of OSA in Malay patients.
  4. Wong ML, Sandham A, Ang PK, Wong DC, Tan WC, Huggare J
    Eur J Orthod, 2005 Feb;27(1):91-7.
    PMID: 15743868
    The aim of this study was to measure craniofacial morphology and nasal respiratory resistance (NRR) in Malay, Indian and Chinese subjects with obstructive sleep apnoea (OSA). The sample consisted of 34 male subjects, 27-52 years of age (Malay n = 11, which included five mild and six moderate-severe OSA; Indian n = 11, which included six mild and five moderate-severe OSA; and Chinese n = 12, which included six mild and six moderate-severe OSA) diagnosed using overnight polysomnography. After use of a decongestant, NRR was recorded using anterior and posterior rhinomanometry. Standardized lateral cephalometric radiographs were used to record linear and angular dimensions. Malay subjects with moderate-severe OSA had a shorter maxillary (sp-pm) and mandibular (gn-go) length when compared with a mild OSA reference sample (P < 0.05). The hyoid bone was located more caudally in the Chinese moderate-severe subjects (hy-NL, hy-ML)(P < 0.05), and may be a useful diagnostic indicator for severity in this racial group. No pattern of differences for NRR was seen between the moderate-severe and mild OSA subjects. The consistently lower values for nasopharyngeal resistance in all the moderate-severe subjects when compared with the mild group may indicate that some compensation at this level of the airway had taken place. Strong positive correlations between craniocervical angulation (NL/OPT) and total airway resistance and the turbulent component of flow (k(2)) suggest that head posture is sensitive to fluctuations in airway resistance (P < 0.01).
  5. Mohd Tahir N, Wan Hassan WN, Saub R
    Eur J Orthod, 2019 08 08;41(4):370-380.
    PMID: 30321319 DOI: 10.1093/ejo/cjy063
    OBJECTIVES: The aim of this study was to compare vacuum-formed thermoplastic retainers (VFRs) constructed on stone models (VFR-CV) and those constructed on three-dimensional (3D) printed models (VFR-3D) based on patients' perspective and post-treatment stability.

    STUDY DESIGN: The research was designed as a crossover, randomized control trial.

    MATERIALS AND METHODS: Subjects comprised patients receiving fixed appliances at a teaching institution and indicated for VFRs. Post-treatment stone models were scanned with a structured-light scanner. A fused deposition modelling machine was used to construct acrylonitrile-butadiene-styrene (ABS)-based replicas from the 3D scanned images. VFRs were fabricated on the original stone and printed models. Analysis comprised independent t-tests and repeated measures analysis of variance.

    RANDOMIZATION: Subjects were allocated to two groups using Latin squares methods and simple randomization. A week after debond, subjects received either VFR-CV first (group A) or VFR-3D first (group B) for 3 months, then the interventions were crossed over for another 3 months.

    BLINDING: In this single-blinded study, subjects were assigned a blinding code for data entry; data were analysed by a third party.

    OUTCOME MEASURES: The primary outcome measured was oral health-related quality of life (OHRQoL) based on Oral Health Impact Profile-14 (OHIP-14). Secondary outcome was post-treatment stability measured using Little's Irregularity Index (LII).

    RESULTS: A total of 30 subjects (15 in each group) were recruited but 3 dropped out. Analysis included 13 subjects from group A and 14 subjects from group B. Group A showed an increase in LII (P < 0.05) after wearing VFR-CV and VFR-3D, whereas group B had no significant increase in LII after wearing both VFRs. Both groups reported significant improvement in OHRQoL after the first intervention but no significant differences after the second intervention. LII changes and OHIP-14 scores at T2 and T3 between groups, and overall between the retainers were not significantly different. No harm was reported during the study.

    CONCLUSION: VFRs made on ABS-based 3D printed models showed no differences in terms of patients' OHRQoL and stability compared with conventionally made retainers.

    REGISTRATION: NCT02866617 (ClinicalTrials.gov).