  1. Yau YH, Chew BT
    Indoor Air, 2009 Dec;19(6):500-10.
    PMID: 19719535 DOI: 10.1111/j.1600-0668.2009.00617.x
    This article presents findings of the thermal comfort study in hospitals. A field survey was conducted to investigate the temperature range for thermal comfort in hospitals in the tropics. Thermal acceptability assessment was conducted to examine whether the hospitals in the tropics met the ASHRAE Standard-55 80% acceptability criteria. A total of 114 occupants in four hospitals were involved in the study. The results of the field study revealed that only 44% of the examined locations met the comfort criteria specified in ASHRAE Standard 55. The survey also examined the predicted percentage of dissatisfied in the hospitals. The results showed that 49% of the occupants were satisfied with the thermal environments in the hospitals. The field survey analysis revealed that the neutral temperature for Malaysian hospitals was 26.4 degrees C. The comfort temperature range that satisfied 90% of the occupants in the space was in the range of 25.3-28.2 degrees C. The results from the field study suggested that a higher comfort temperature was required for Malaysians in hospital environments compared with the temperature criteria specified in ASHRAE Standard (2003). In addition, the significant deviation between actual mean vote and predicted mean vote (PMV) strongly implied that PMV could not be applied without errors in hospitals in the tropics.
  2. Yap HS, Roberts AC, Luo C, Tan Z, Lee EH, Thach TQ, et al.
    Indoor Air, 2021 11;31(6):2239-2251.
    PMID: 34096640 DOI: 10.1111/ina.12863
    Space is a resource that is constantly being depleted, especially in mega-cities. Underground workspaces (UGS) are increasingly being included in urban plans and have emerged as an essential component of vertical cities. While progress had been made on the engineering aspects associated with the development of high-quality UGS, public attitudes toward UGS as work environments (ie, the public's design concerns with UGS) are relatively unknown. Here, we present the first large-scale study examining preferences and attitudes toward UGS, surveying close to 2000 participants from four cities in three continents (Singapore, Shanghai, London, and Montreal). Contrary to previous beliefs, air quality (and not lack of windows) is the major concern of prospective occupants. Windows, temperature, and lighting emerged as additional important building performance aspects for UGS. Early adopters (ie, individuals more willing to accept UGS and thus more likely to be the first occupants) across all cities prioritized air quality. Present results suggest that (perceived) air quality is a key building performance aspect for UGS that needs to be communicated to prospective occupants as this will improve their attitudes and views toward UGS. This study highlights the importance of indoor air quality for the public.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links