Displaying publications 1 - 20 of 37 in total

Abstract:
Sort:
  1. Thalayasingam M, Veerakumarasivam A, Kulanthayan S, Khairuddin F, Cheah IG
    Injury, 2012 Dec;43(12):2083-7.
    PMID: 22424957 DOI: 10.1016/j.injury.2012.02.010
    Identifying the differences between infants with non-accidental head injuries (NAHI) and accidental head injuries (AHI) may help alert clinicians to recognize markers of abuse. A retrospective review of infants <1 year of age admitted to a tertiary referral centre in Malaysia over a two year period with a diagnosis of head injury or abnormal computed tomography head scans was conducted to identify the clinical features pointing towards a diagnosis of NAHI by comparing the socio-demographics, presenting complaints, clinical features and the extent of hospital investigations carried out. NAHI infants were more likely to be symptomatic, under a non-related caregiver's supervision, and presented with inconsistent or no known mechanism of injury. Subdural haemorrhages were more common in NAHI infants. The history, mechanism of injury, presenting signs and symptoms as well as the nature of the injuries sustained are all valuable clues as to whether a head injury sustained during infancy is likely to be accidental or not.
  2. Kulanthayan S, See LG, Kaviyarasu Y, Nor Afiah MZ
    Injury, 2012 May;43(5):653-9.
    PMID: 21764054 DOI: 10.1016/j.injury.2011.06.197
    BACKGROUND: Almost half of the global traffic crashes involve vulnerable groups such as pedestrian, cyclists and two-wheeler users. The main objective of this study was to determine the factors that influence standard of the safety helmets used amongst food delivery workers by presence of Standard and Industrial Research Institute of Malaysia (SIRIM) certification label.
    METHODS: A cross sectional study was conducted amongst 150 food delivery workers from fast food outlets in the vicinity of Selangor and Kuala Lumpur. During observation, safety helmets were classified as standard safety helmet in the presence of SIRIM label and non-standard in the absence of the label. They were approached for questionnaire participation once consent was obtained and were requested to exchange their safety helmet voluntarily with a new one after the interview. Data analysis was carried out using SPSS. Chi square and logistic regression analysis was applied to determine the significance and odds ratio of the variables studied, respectively (penetration test, age, education level, knowledge, crash history, types of safety helmet, marital status and years of riding experience) against the presence of SIRIM label.
    RESULTS: The response rate for this study was 85.2%. The prevalence of non-standard helmets use amongst fast food delivery workers was 55.3%. Safety helmets that failed the penetration test had higher odds of being non-standard helmets compared with safety helmets passing the test. Types of safety helmet indicated half-shell safety helmets had higher odds to be non-standard safety helmets compared to full-shell safety helmets. Riders with more years of riding experience were in high odds of wearing non-standard safety helmets compared to riders with less riding experience.
    CONCLUSION: Non-standard (non-SIRIM approved) helmets were more likely to be half-shell helmets, were more likely to fail the standards penetration test, and were more likely to be worn by older, more experienced riders. The implications of these findings are discussed.
  3. Raja Izaham RM, Abdul Kadir MR, Abdul Rashid AH, Hossain MG, Kamarul T
    Injury, 2012 Jun;43(6):898-902.
    PMID: 22204773 DOI: 10.1016/j.injury.2011.12.006
    The use of open wedge high tibial osteotomy (HTO) to correct varus deformity of the knee is well established. However, the stability of the various implants used in this procedure has not been previously demonstrated. In this study, the two most common types of plates were analysed (1) the Puddu plates that use the dynamic compression plate (DCP) concept, and (2) the Tomofix plate that uses the locking compression plate (LCP) concept. Three dimensional model of the tibia was reconstructed from computed tomography images obtained from the Medical Implant Technology Group datasets. Osteotomy and fixation models were simulated through computational processing. Simulated loading was applied at 60:40 ratios on the medial:lateral aspect during single limb stance. The model was fixed distally in all degrees of freedom. Simulated data generated from the micromotions, displacement and, implant stress were captured. At the prescribed loads, a higher displacement of 3.25 mm was observed for the Puddu plate model (p<0.001). Coincidentally the amount of stresses subjected to this plate, 24.7 MPa, was also significantly lower (p<0.001). There was significant negative correlation (p<0.001) between implant stresses to that of the amount of fracture displacement which signifies a less stable fixation using Puddu plates. In conclusion, this study demonstrates that the Tomofix plate produces superior stability for bony fixation in HTO procedures.
  4. Kanthan SR, Kavitha G, Addi S, Choon DS, Kamarul T
    Injury, 2011 Aug;42(8):782-9.
    PMID: 21329922 DOI: 10.1016/j.injury.2011.01.015
    The use of bone grafts in treating non- or delayed unions as the result of large bone loss is well established. However, despite good outcomes, the time to achieve complete union is still considerably long. To overcome this problem, the use of platelet-rich plasma (PRP) has been advocated albeit with varying success. To determine the true effectiveness of PRP in treating non-/delayed unions, a study was conducted using (n=12) rabbit models.
  5. Yusof NM, Oh CW, Oh JK, Kim JW, Min WK, Park IH, et al.
    Injury, 2009 Dec;40(12):1286-91.
    PMID: 19539282 DOI: 10.1016/j.injury.2009.02.020
    Although non-operative treatment is a mainstay of tibial fracture management in children, certain fractures require a surgical approach. However, choices concerning optimal methods and implants are difficult. The purpose of this study was to determine the effectiveness of percutaneous plating of tibial fractures in children.
  6. Louahem D, Cottalorda J
    Injury, 2016 Apr;47(4):848-52.
    PMID: 26861802 DOI: 10.1016/j.injury.2016.01.010
    No consensus exists regarding pulseless otherwise well-perfused hand in pediatric Gartland type III fractures. The purpose of this retrospective study was to describe our strategy and to determine the guidelines of therapeutic consensus.
  7. Yew CC, Shaari R, Rahman SA, Alam MK
    Injury, 2015 Sep;46(9):1856-9.
    PMID: 25986667 DOI: 10.1016/j.injury.2015.04.025
    White-eyed blowout fracture was first termed by Jordan et al. in individuals sustaining a blow to the periocular area and presenting with ocular symptoms, although with minimal soft tissue signs of trauma. It is often found in pure orbital floor blowout fractures among paediatric patients, and it could manifest as a linear or hinge-like trapdoor deformity. Unlike the more common open orbital blowout fractures with distinct diagnostic clinical signs, white-eyed blowout fractures are rarer and their diagnoses can be easily missed, subsequently costing an optimal time window for surgical intervention. This is critical as better outcomes are found with earlier release of entrapments. This report describes a case of a white-eyed blowout fracture in a 10-year-old child faced with its diagnostic challenges. The current literature review discusses the types of fracture pattern, signs and symptoms, mechanism of action, as well as timing of surgery. In view of the common complication of persistent diplopia, clinical pitfalls in achieving this diagnosis are emphasized to prevent any delay of treatment. Current literature evidences are weighted towards urgent surgical intervention, as positive outcomes are found to correlate with earlier release of entrapments.
  8. Ong CT, Choon DS, Cabrera NP, Maffulli N
    Injury, 2002 Nov;33(9):829-34.
    PMID: 12379395
    We report the results of external fixation in 29 patients treated for tibial fractures and tibial non-union using a novel multi axial external fixator (MAXX) followed prospectively until bony union. The results of treatment were classified according to the Association for the Study and Application of the Method of Ilizarov (ASAMI). Overall, 13 patients had excellent bone results; 13 had good bone results; two had fair bone results, and 1 patient had poor bone results. Regarding functional results, 21 patients had excellent results; 6 obtained good results; none had fair results, and two had poor results. Acute patients did better functionally than chronic patients. This fixator is safe and versatile, although the indications for its use are very specific.
  9. Marwan M, Ibrahim M
    Injury, 1999 Jun;30(5):333-5.
    PMID: 10505126
    A simple technique for removal of the distal fragment of the broken intramedullary interlocking nail is described. It was successfully used in three patients with a broken nail due to nonunion. The technique requires only cerclage wire, which is available in any operating room, avoiding the difficulties obtaining the custom made hook and of excessive exposure to radiation.
  10. Sivananthan KS, Raveendran K, Kumar T, Sivananthan S
    Injury, 2000 Jul;31(6):433-4.
    PMID: 10831741
    The removal of broken implanted intramedullary nails secondary to re-fracture or non-union is challenging. In 12 cases a simple and safe method has been used to remove broken implants.
  11. Pan KL, Shukur MH, Ghani MA
    Injury, 1994 Dec;25(10):655-7.
    PMID: 7829188
    Ten patients with complex non-union of the tibia were treated by locked intramedullary nailing. These patients had scarred skin as a result of initial severe open fractures, multiple debridement or fasciotomies with external fixators and skin grafts applied. Seven of the patients also had previous osteomyelitis or pin track infections. Fully pain-free walking was achieved in all patients and radiological union in nine patients without the need for a bone graft. Four patients developed infection after nailing, of which three resolved with treatment.
  12. Chin CH, Chew KC
    Injury, 1998 6 13;28(9-10):674-8.
    PMID: 9624350
    Lumbosacral nerve root avulsion is a rare clinical entity. Since the first description in 1955, only 35 cases have been reported. It is often associated with pelvic fractures and may be missed in the initial clinical examination as these patients usually present with multiple injuries. We present three such cases with clinical and radiological findings. These patients were involved in road traffic accidents. Two had fractures of the sacroiliac joint with diastasis of the symphysis pubis (Tile type C 1.2) and one had fractures of the public rami (Tile type B 2.1). All three had various degrees of sensory and motor deficit of the lower limbs. Lumbar myelogram shows characteristic pseudomeningoceles in the affected lumboscral region. Magnetic resonance (MR) imaging provides an additional non-invasive modality to diagnose this condition.
  13. Devnani AS
    Injury, 1998 6 13;28(9-10):643-7.
    PMID: 9624344
    Cubitus varus deformity following mal-union of a supracondylar fracture of the humerus in children causes no functional disability, but surgical correction is often requested to improve the appearance of the arm. Maintaining the correction after supracondylar osteotomy is a difficult aspect of the operative treatment and remains controversial. Nine children aged between 6 and 12 years (average 8 years and 11 months) underwent lateral closing wedge supracondylar osteotomy of the humerus, for deformity ranging between 10 and 20 degrees (average 13 degrees). The correction required ranged between 16 and 30 degrees (average 21 degrees). The osteotomy was internally fixed with a two hole marrow plate. At follow-up, which ranged between 3 months and 6 years (average 34 months), six patients were graded as good, two as satisfactory and one as a poor result. One patient had transient radial nerve palsy which recovered completely in 2 months. The patient who was graded poor had undercorrection of the deformity at the original operation. There was no incidence of loss of correction due to implant failure. Complete section of the bone to allow medial displacement of the distal fragment is recommended, thereby avoiding lateral bony prominence at the elbow.
  14. Devnani AS
    Injury, 1997 Mar;28(2):131-3.
    PMID: 9205580
    Open reduction of the radial head and reconstruction of the annular ligament has been advocated for the Monteggia fracture dislocation in children who present more than a month after injury. Three patients with an anterior Monteggia lesion were treated by open reduction of the radial head which was held in place by a Kirschner wire passed from the humerus to the radius. No attempt was made either to repair or reconstruct the annular ligament. The patients were aged between 2 and 6 years, the delay between injury and reduction was between 6 and 8 weeks, and the length of follow up was 5 years for two patients and 1 year for the third. All three patients were free of pain, had no deformity and the radial head had not subluxated. All had nearly full flexion at the elbow. The forearm had full supination but restricted pronation.
  15. Deshmukh RG, Lou KK, Neo CB, Yew KS, Rozman I, George J
    Injury, 1998 Apr;29(3):207-10.
    PMID: 9709422
    Closed intramedullary nailing is a successful method of treating adult femoral shaft fractures. In comminuted or segmental fractures, this operation is associated with an incidence of rotational malalignment and malunion. After locked nailing, this can only be corrected by further operation. A simple method of judging and obtaining rotational alignment in such cases intra-operatively is described. A comparison of two groups of patients with such fractures, one using this technique and the other using conventional methods of judging alignment, revealed statistically significant improvement in rotational alignment (p = 0.016).
  16. Noor MA
    Injury, 1988 Nov;19(6):377-8.
    PMID: 3267638
    A simple and inexpensive external fixator has been designed. It is constructed of galvanized iron pipe and mild steel bolts and nuts. It can easily be manufactured in a hospital workshop with a minimum of tools.
  17. Sidhu JS, Dhillon MK
    Injury, 1991 Mar;22(2):156-8.
    PMID: 2037340
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links