Displaying all 8 publications

Abstract:
Sort:
  1. Tenekecioglu E, Serruys PW, Onuma Y, Costa R, Chamié D, Sotomi Y, et al.
    JACC Cardiovasc Interv, 2017 06 12;10(11):1115-1130.
    PMID: 28527768 DOI: 10.1016/j.jcin.2017.03.015
    OBJECTIVES: The primary objective of this study was to evaluate the safety and effectiveness of the Mirage (Manli Cardiology, Singapore) bioresorbable microfiber sirolimus-eluting scaffold compared with the Absorb (Abbott Vascular, Santa Clara, California) bioresorbable vascular scaffold in the treatment of stenotic target lesions located in native coronary arteries, ranging from ≥2.25 to ≤4.0 mm in diameter. Secondary objectives were to establish the medium-term safety, effectiveness, and performance of the Mirage device.

    BACKGROUND: The current generation of bioresorbable scaffolds has several limitations, such as thick square struts with large footprints that preclude their deep embedment into the vessel wall, resulting in protrusion into the lumen with microdisturbance of flow. The Mirage sirolimus-eluting bioresorbable microfiber scaffold is designed to address these concerns.

    METHODS: In this prospective, single-blind trial, 60 patients were randomly allocated in a 1:1 ratio to treatment with a Mirage sirolimus-eluting bioresorbable microfiber scaffold or an Absorb bioresorbable vascular scaffold. The clinical endpoints were assessed at 30 days and at 6 and 12 months. In-device angiographic late loss at 12 months was quantified. Secondary optical coherence tomographic endpoints were assessed post-scaffold implantation at 6 and 12 months.

    RESULTS: Median angiographic post-procedural in-scaffold minimal luminal diameters of the Mirage and Absorb devices were 2.38 mm (interquartile range [IQR]: 2.06 to 2.62 mm) and 2.55 mm (IQR: 2.26 to 2.71 mm), respectively; the effect size (d) was -0.29. At 12 months, median angiographic in-scaffold minimal luminal diameters of the Mirage and Absorb devices were not statistically different (1.90 mm [IQR: 1.57 to 2.31 mm] vs. 2.29 mm [IQR: 1.74 to 2.51 mm], d = -0.36). At 12-month follow-up, median in-scaffold late luminal loss with the Mirage and Absorb devices was 0.37 mm (IQR: 0.08 to 0.72 mm) and 0.23 mm (IQR: 0.15 to 0.37 mm), respectively (d = 0.20). On optical coherence tomography, post-procedural diameter stenosis with the Mirage was 11.2 ± 7.1%, which increased to 27.4 ± 12.4% at 6 months and remained stable (31.8 ± 12.9%) at 1 year, whereas the post-procedural optical coherence tomographic diameter stenosis with the Absorb was 8.4 ± 6.6%, which increased to 16.6 ± 8.9% and remained stable (21.2 ± 9.9%) at 1-year follow-up (Mirage vs. Absorb: dpost-procedure = 0.41, d6 months = 1.00, d12 months = 0.92). Angiographic median in-scaffold diameter stenosis was significantly different between study groups at 12 months (28.6% [IQR: 21.0% to 40.7%] for the Mirage, 18.2% [IQR: 13.1% to 31.6%] for the Absorb, d = 0.39). Device- and patient-oriented composite endpoints were comparable between the 2 study groups.

    CONCLUSIONS: At 12 months, angiographic in-scaffold late loss was not statistically different between the Mirage and Absorb devices, although diameter stenosis on angiography and on optical coherence tomography was significantly higher with the Mirage than with the Absorb. The technique of implantation was suboptimal for both devices, and future trials should incorporate optical coherence tomographic guidance to allow optimal implantation and appropriate assessment of the new technology, considering the novel mechanical properties of the Mirage.

  2. Chen YH, Leong WS, Lin MS, Huang CC, Hung CS, Li HY, et al.
    JACC Cardiovasc Interv, 2016 09 12;9(17):1825-32.
    PMID: 27609258 DOI: 10.1016/j.jcin.2016.06.015
    OBJECTIVES: This study sought to determine predictors for successful endovascular treatment in patients with chronic carotid artery occlusion (CAO).

    BACKGROUND: Endovascular recanalization in patients with chronic CAO has been reported to be feasible, but technically challenging.

    METHODS: Endovascular attempts in 138 consecutive chronic CAO patients with impaired ipsilateral hemisphere perfusion were reviewed. We analyzed potential variables including epidemiology, symptomatology, angiographic morphology, and interventional techniques in relation to the technical success.

    RESULTS: The technical success rate was 61.6%. Multivariate analysis showed absence of prior neurologic event (odds ratio [OR]: 0.27; 95% confidence interval [CI]: 0.10 to 0.76), nontapered stump (OR: 0.18; 95% CI: 0.05 to 0.67), distal internal carotid artery (ICA) reconstitution via contralateral injection (OR: 0.19; 95% CI: 0.05 to 0.75), and distal ICA reconstitution at communicating or ophthalmic segments (OR:0.12; 95% CI: 0.04 to 0.36) to be independent factors associated with lower technical success. Point scores were assigned proportional to model coefficients, and technical success rates were >80% and <40% in patients with scores of ≤1 and ≥4, respectively. The c-indexes for this score system in predicting technical success was 0.820 (95% CI: 0.748 to 0.892; p < 0.001) with a sensitivity of 84.7% and a specificity of 67.9%.

    CONCLUSIONS: Absence of prior neurologic event, nontapered stump, distal ICA reconstitution via contralateral injection, and distal ICA reconstitution at communicating or ophthalmic segments were identified as independent negative predictors for technical success in endovascular recanalization for CAO.

  3. Garcia S, Bhatt DL, Gallagher M, Jneid H, Kaufman J, Palevsky PM, et al.
    JACC Cardiovasc Interv, 2018 11 26;11(22):2254-2261.
    PMID: 30466822 DOI: 10.1016/j.jcin.2018.07.044
    OBJECTIVES: The aim of this study was to compare intravenous (IV) sodium bicarbonate with IV sodium chloride and oral acetylcysteine with placebo for the prevention of contrast-associated acute kidney injury (CAAKI) and intermediate-term adverse outcomes.

    BACKGROUND: Data are conflicting on the optimal strategy to reduce CAAKI and related complications after percutaneous coronary intervention (PCI).

    METHODS: The PRESERVE (Prevention of Serious Adverse Events Following Angiography) trial used a 2 × 2 factorial design to randomize 5,177 patients with stage III or IV chronic kidney disease undergoing angiography to IV 1.26% sodium bicarbonate or IV 0.9% sodium chloride and 5 days of oral acetylcysteine or placebo. A subgroup analysis was conducted of the efficacy of these interventions in patients who underwent PCI during the study angiographic examination. The primary endpoint was a composite of death, need for dialysis, or persistent kidney impairment at 90 days; CAAKI was a secondary endpoint.

    RESULTS: A total of 1,161 PRESERVE patients (mean age 69 ± 8 years) underwent PCI. The median estimated glomerular filtration rate was 50.7 ml/min/1.73 m2 (interquartile range: 41.7 to 60.1 ml/min/1.73 m2), and 952 patients (82%) had diabetes mellitus. The primary endpoint occurred in 15 of 568 patients (2.6%) in the IV sodium bicarbonate group and 24 of 593 patients (4.0%) in the IV sodium chloride group (odds ratio: 0.64; 95% confidence interval: 0.33 to 1.24; p for interaction = 0.41) and in 23 of 598 patients (3.8%) in the acetylcysteine group and 16 of 563 patients (2.8%) in the placebo group (odds ratio: 1.37; 95% confidence interval: 0.71 to 2.62; p for interaction = 0.29). There were no significant between-group differences in the rates of CAAKI.

    CONCLUSIONS: Among patients with CKD undergoing PCI, there was no benefit of IV sodium bicarbonate over IV sodium chloride or of acetylcysteine over placebo for the prevention of CAAKI or intermediate-term adverse outcomes.

  4. Ali RM, Abdul Kader MASK, Wan Ahmad WA, Ong TK, Liew HB, Omar AF, et al.
    JACC Cardiovasc Interv, 2019 Mar 25;12(6):558-566.
    PMID: 30898253 DOI: 10.1016/j.jcin.2018.11.040
    OBJECTIVES: The aim of this randomized controlled trial was to investigate a novel sirolimus-coated balloon (SCB) compared with the best investigated paclitaxel-coated balloon (PCB).

    BACKGROUND: Treatment of coronary in-stent restenosis (ISR) remains challenging. PCBs are an established treatment option outside the United States with a Class I, Level of Evidence: A recommendation in the European guidelines. However, their efficacy is better in bare-metal stent (BMS) ISR compared with drug-eluting stent (DES) ISR.

    METHODS: Fifty patients with DES ISR were enrolled in a randomized, multicenter trial to compare a novel SCB (SeQuent SCB, 4 μg/mm2) with a clinically proven PCB (SeQuent Please Neo, 3 μg/mm2) in coronary DES ISR. The primary endpoint was angiographic late lumen loss at 6 months. Secondary endpoints included procedural success, major adverse cardiovascular events, and individual clinical endpoints such as stent thrombosis, cardiac death, target lesion myocardial infarction, clinically driven target lesion revascularization, and binary restenosis.

    RESULTS: Quantitative coronary angiography revealed no differences in baseline parameters. After 6 months, in-segment late lumen loss was 0.21 ± 0.54 mm in the PCB group versus 0.17 ± 0.55 mm in the SCB group (p = NS; per-protocol analysis). Clinical events up to 12 months also did not differ between the groups.

    CONCLUSIONS: This first-in-man comparison of a novel SCB with a crystalline coating shows similar angiographic outcomes in the treatment of coronary DES ISR compared with a clinically proven PCB. (Treatment of Coronary In-Stent Restenosis by a Sirolimus [Rapamycin] Coated Balloon or a Paclitaxel Coated Balloon [FIM LIMUS DCB]; NCT02996318).

  5. Jeger RV, Eccleshall S, Wan Ahmad WA, Ge J, Poerner TC, Shin ES, et al.
    JACC Cardiovasc Interv, 2020 06 22;13(12):1391-1402.
    PMID: 32473887 DOI: 10.1016/j.jcin.2020.02.043
    Although drug-eluting stents are still the default interventional treatment of coronary artery disease, drug-coated balloons (DCBs) represent a novel alternative therapeutic strategy in certain anatomic conditions. The effect of DCBs is based on the fast and homogenous transfer of antiproliferative drugs into the vessel wall during single balloon inflation by means of a lipophilic matrix without the use of permanent implants. Although their use is established for in-stent restenosis of both bare-metal and drug-eluting stents, recent randomized clinical data demonstrate a good efficacy and safety profile in de novo small-vessel disease and high bleeding risk. In addition, there are other emerging indications (e.g., bifurcation lesions, large-vessel disease, diabetes mellitus, acute coronary syndromes). Because the interaction among the different delivery balloon designs, doses, formulations, and release kinetics of the drugs used is important, there seems to be no "class effect" of DCBs. On the basis of the amount of recently published data, the International DCB Consensus Group provides this update of previous recommendations summarizing the historical background, technical considerations such as choice of device and implantation technique, possible indications, and future perspectives.
  6. Cortese B, Testa L, Heang TM, Ielasi A, Bossi I, Latini RA, et al.
    JACC Cardiovasc Interv, 2023 Jul 24;16(14):1794-1803.
    PMID: 37495352 DOI: 10.1016/j.jcin.2023.05.005
    BACKGROUND: Drug-coated balloons (DCB) represent 1 of the most promising innovations in interventional cardiology and may represent a valid alternative to drug-eluting stents. Currently, some sirolimus-coated balloons (SCB) are being investigated for several coronary artery disease applications.

    OBJECTIVES: This study sought to understand the role of a novel SCB for the treatment of coronary artery disease.

    METHODS: EASTBOURNE (All-Comers Sirolimus-Coated Balloon European Registry) is a prospective, multicenter, investigator-driven clinical study that enrolled real-world patients treated with SCB. Primary endpoint was target lesion revascularization (TLR) at 12 months. Secondary endpoints were procedural success, myocardial infarction (MI), all-cause death, and major adverse clinical events (a composite of death, MI, and TLR). All adverse events were censored and adjudicated by an independent clinical events committee.

    RESULTS: A total population of 2,123 patients (2,440 lesions) was enrolled at 38 study centers in Europe and Asia. The average age was 66.6 ± 11.3 years, and diabetic patients were 41.5%. De novo lesions (small vessels) were 56%, in-stent restenosis (ISR) 44%, and bailout stenting occurred in 7.7% of the patients. After 12 months, TLR occurred in 5.9% of the lesions, major adverse clinical events in 9.9%, and spontaneous MI in 2.4% of the patients. The rates of cardiac/all-cause death were 1.5% and 2.5%, respectively. The primary outcome occurred more frequently in the ISR cohort (10.5% vs 2.0%; risk ratio: 1.90; 95% CI: 1.13-3.19). After multivariate Cox regression model, the main determinant for occurrence of the primary endpoint was ISR (OR: 5.5; 95% CI: 3.382-8.881).

    CONCLUSIONS: EASTBOURNE, the largest DCB study in the coronary field, shows the safety and efficacy of a novel SCB in a broad population of coronary artery disease including small vessels and ISR patients at mid-term follow-up. (The All-Comers Sirolimus-Coated Balloon European Registry [EASTBOURNE]; NCT03085823).

  7. Kim H, Kang DY, Ahn JM, Lee J, Choi Y, Hur SH, et al.
    JACC Cardiovasc Interv, 2023 Oct 09;16(19):2412-2422.
    PMID: 37821187 DOI: 10.1016/j.jcin.2023.07.028
    BACKGROUND: Diabetes mellitus is associated with more complex coronary artery diseases. Coronary artery bypass grafting (CABG) is a preferred revascularization strategy over percutaneous coronary intervention (PCI) in diabetics with multivessel coronary artery disease (MVD).

    OBJECTIVES: This study sought to examine the different prognostic effects of revascularization strategies according to the diabetes status from the randomized BEST (Randomized Comparison of Coronary Artery Bypass Surgery and Everolimus-Eluting Stent Implantation in the Treatment of Patients With Multivessel Coronary Artery Disease) trial.

    METHODS: Patients (n = 880) with MVD were randomly assigned to undergo PCI with an everolimus-eluting stent vs CABG stratified by diabetics (n = 363) and nondiabetics (n = 517). The primary endpoint was the composite of death, myocardial infarction, or target vessel revascularization during a median follow-up of 11.8 years (IQR: 10.6-12.5 years).

    RESULTS: In diabetics, the primary endpoint rate was significantly higher in the PCI group than in the CABG group (43% and 32%; HR: 1.53; 95% CI: 1.12-2.08; P = 0.008). However, in nondiabetics, no significant difference was found between the groups (PCI group, 29%; CABG group, 29%; HR: 0.97; 95% CI: 0.67-1.39; P = 0.86; Pinteraction= 0.009). Irrespective of the presence of diabetes, no significant between-group differences were found in the rate of a safety composite of death, myocardial infarction, or stroke and mortality rate. However, the rate of any repeat revascularization was significantly higher in the PCI group than in the CABG group.

    CONCLUSIONS: In diabetics with MVD, CABG was associated with better clinical outcomes than PCI. However, the mortality rate was similar between PCI and CABG irrespective of diabetes status during an extended follow-up. (Ten-Year Outcomes of Randomized Comparison of Coronary Artery Bypass Surgery and Everolimus-Eluting Stent Implantation in the Treatment of Patients With Multivessel Coronary Artery Disease [BEST Extended], NCT05125367; Randomized Comparison of Coronary Artery Bypass Surgery and Everolimus-Eluting Stent Implantation in the Treatment of Patients With Multivessel Coronary Artery Disease [BEST], NCT00997828).

Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links